A Realistic X-Ray Simulation for C-Arm Geometry Calibration

被引:0
|
作者
Thuerauf, Sabine [1 ]
Wolf, Markus [2 ]
Koerner, Mario [2 ]
Vogt, Florian [2 ]
Hornung, Oliver [2 ]
Nasseri, M. Ali [3 ]
Knoll, Alois [4 ]
机构
[1] Fortiss GmbH, D-80805 Munich, Germany
[2] Siemens Healthcare GmbH, D-91301 Forchheim, Germany
[3] Klinikum Rechts Der Isar, D-81675 Munich, Germany
[4] Tech Univ Munich, Fac Comp Sci, Chair Robot & Embedded Syst, D-85748 Garching, Germany
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Applications like cone beam computed tomographies (CBCTs) or 2D-3D overlays need a high geometrical accuracy of the C-arm system. In order to achieve this, geometry calibrations are performed to increase the accuracy given by the kinematics of the system. Commonly X-ray images of a phantom with known geometry are taken for the calibration. The images, together with a 3D model of the phantom, serve as input for an optimizer, which estimates the pose of the C-arm relative to the phantom. Afterwards, the estimates are used to increase the geometrical accuracy of the system. Inaccuracies due to real world effects appear, e.g. manufacturing or assembly inaccuracies of the phantom, the position of the X-ray tube, or the pose of the detector. To evaluate these factors separately a simulation is helpful, which needs to be as realistic as possible. To achieve this we defined three requirements, which have to be fulfilled: realistic noise, realistic absolute errors and similar error distributions within the working volume. By means of these criteria we investigate if our simulation mirrors a real world C-arm pose measurement for C-arm geometry calibration sufficiently.
引用
收藏
页码:383 / 388
页数:6
相关论文
共 50 条
  • [31] GEOMETRY, ALIGNMENT AND ANGULAR CALIBRATION OF X-RAY DIFFRACTOMETERS
    PARRISH, W
    LOWITZSCH, K
    [J]. AMERICAN MINERALOGIST, 1959, 44 (7-8) : 765 - 787
  • [32] Real-time, ray casting-based scatter dose estimation for c-arm x-ray system
    Alnewaini, Zaid
    Langer, Eric
    Schaber, Philipp
    David, Matthias
    Kretz, Dominik
    Steil, Volker
    Hesser, Juergen
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (02): : 144 - 153
  • [33] A Realistic Collimated X-Ray Image Simulation Pipeline
    El-Zein, Benjamin
    Eckert, Dominik
    Weber, Thomas
    Rohleder, Maximilian
    Ritschl, Ludwig
    Kappler, Steffen
    Maier, Andreas
    [J]. DATA AUGMENTATION, LABELLING, AND IMPERFECTIONS, DALI 2023, 2024, 14379 : 137 - 145
  • [34] Analysis of radiation risk to patients from intraoperative use of the mobile X-ray system (C-arm)
    Lee, Yang-Sub
    Lee, Hae-Kag
    Cho, Jae-Hwan
    Kim, Ham-Gyum
    [J]. JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2015, 20 (01): : 7 - 12
  • [35] Clinical validation and performance evaluation of enhancement methods acquired from interventional C-ARM X-ray
    Wei, Liyang
    Kumar, Dinesh
    Khemka, Animesh
    Turlapati, Ram
    Suri, Jasjit S.
    [J]. MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914
  • [36] The Research of global correction for c-arm x-ray image based on pin-hole model
    Zhou, Xiaojun
    Meng, Cai
    Fan, Limin
    Lv, Shaojie
    [J]. PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 435 - +
  • [37] SEMI-AUTOMATIC POSITIONING OF THE PROTECTIVE SCREEN BASED ON INTEGRATION WITH A C-ARM X-RAY DEVICE
    Antic, Vojislav M.
    [J]. NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2021, 36 (01): : 85 - 90
  • [38] 3-D Reconstruction of Historical Documents using an X-Ray C-Arm CT System
    Stromer, Daniel
    Anton, Gisela
    Christlein, Vincent
    Maier, Andreas
    Kugler, Patrick
    [J]. PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON IMAGE AND VISION COMPUTING NEW ZEALAND (IVCNZ), 2016, : 303 - 308
  • [39] 3D ablation catheter localisation using individual C-arm x-ray projections
    Haase, C.
    Schaefer, D.
    Doessel, O.
    Grass, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : 6959 - 6977
  • [40] Image Quality Assessment, Denoising and Comparative Analysis using Filters for C-arm X-ray Images
    Yadav, Snehal
    Kulkarni, Saket
    Patole, Rashmika
    [J]. PROCEEDINGS OF THE 2019 IEEE REGION 10 CONFERENCE (TENCON 2019): TECHNOLOGY, KNOWLEDGE, AND SOCIETY, 2019, : 2143 - 2147