Calibration of a low-level anti-Compton underground gamma-spectrometer by experiment and Monte Carlo

被引:7
|
作者
Sima, Octavian [1 ]
Osvath, Iolanda [2 ]
机构
[1] Univ Bucharest, Dept Phys, RO-077125 Bucharest, Romania
[2] IAEA Environm Labs, MC-98000 Monte Carlo, Monaco
关键词
Compton-suppressed HPGe spectrometer; Efficiency calibration; Corrections due to coincidence effects; Efficiency evaluation by Monte Carlo; COINCIDENCE-SUMMING CORRECTIONS; RAY SPECTROMETRY; VOLUME SOURCES; SIMULATIONS; COMPUTATION; EFFICIENCY; TOOL;
D O I
10.1016/j.apradiso.2013.03.025
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this work we present the experimental and Monte Carlo calibration of the Compton-suppressed spectrometer of the IAEA's Environment Laboratories, Monaco. For this purpose the GESPECOR code was extended to include the specific geometry and to implement the veto logic, integrated with the coincidence summing module of the code. The simulation results are in good accordance with experimental calibrations. The code is fast and user-friendly, able to evaluate the efficiency and the correction factors for nuclides with arbitrary complex decay schemes. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:109 / 113
页数:5
相关论文
共 50 条
  • [21] Resolution test technique and influencing factors analysis of a low-background anti-Compton HPGe γ-ray spectrometer
    Zhou Chunlin
    Xu Zhenhua
    Xu Congxue
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL I, 2007, : 571 - 575
  • [22] Simulation of background characteristics of low-level gamma-ray spectrometers using Monte Carlo method
    Breier, R.
    Povinec, P. P.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1231 - 1235
  • [23] GE(LI)-NAL(TL) COMPTON SUPPRESSION SPECTROMETER FOR LOW-LEVEL ACTIVITY MEASUREMENTS
    SITAR, B
    USACEV, S
    CHRAPAN, J
    ORAVEC, J
    JADERNA ENERGIE, 1977, 23 (08): : 298 - 301
  • [24] A Monte Carlo simulation of background characteristics of low-level HPGe detectors
    Vojtyla, P
    Povinec, PP
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (1-2) : 185 - 190
  • [25] ANTICOINCIDENCE GAMMA-RAY SPECTROMETER FOR MEASUREMENT OF LOW-LEVEL RADIOACTIVITY
    SURKOV, YA
    SOBORNOV, OP
    ATOMNAYA ENERGIYA, 1973, 34 (02): : 125 - 127
  • [26] DUAL PARAMETER GAMMA-RAY SPECTROMETER FOR LOW-LEVEL COUNTING
    POVINEC, P
    ISOTOPENPRAXIS, 1982, 18 (03): : 92 - 95
  • [27] STUDIES OF GAMMA-RAY BACKGROUND WITH A LOW-LEVEL GERMANIUM SPECTROMETER
    HEUSSER, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 58 (01): : 79 - 84
  • [28] Development of a low-level background gamma-ray spectrometer by KRISS
    Lee, K. B.
    Park, Tae Soon
    Lee, Jong Man
    Oh, Phil-Je
    Lee, Sang-Han
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 845 - 849
  • [29] Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level gamma-ray spectrometry using well-type HPGe detectors
    Laborie, JM
    Le Petit, G
    Abt, D
    Girard, M
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (1-2) : 57 - 62
  • [30] GE(LI) LOW-LEVEL IN-SITU GAMMA-RAY SPECTROMETER APPLICATIONS
    PHELPS, PL
    ANSPAUGH, LR
    ROTH, SJ
    HUCKABAY, GW
    SAWYER, DL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 543 - 552