A FLUKA Monte Carlo Computational Model of a Scanning Proton Beam Therapy Nozzle at IU Proton Therapy Center

被引:3
|
作者
Moskvin, V. [1 ,2 ]
Cheng, C. [1 ,3 ]
Anferov, V. [4 ]
Nichiporov, D. [2 ]
Zhao, Q. [3 ]
Takashina, M. [5 ]
Parola, R. [6 ]
Das, I. [1 ,3 ]
机构
[1] Indiana Univ, Sch Med, Dept Radiat Oncol, Indianapolis, IN 46202 USA
[2] IU Hlth Protons Therapy Ctr, Bloomington, IN USA
[3] Indiana Univ, Hlth Proton Therapy Ctr, Bloomington, IN USA
[4] ProCure, Bloomington, IN USA
[5] Osaka Univ, Dept Med Phys & Engn, Osaka, Japan
[6] John H Stroger Jr Hosp Cook Cty, Chicago, IL USA
关键词
D O I
10.1118/1.4735580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3818 / 3818
页数:1
相关论文
共 50 条
  • [21] Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy
    Huang, Sheng
    Kang, Minglei
    Souris, Kevin
    Ainsley, Christopher
    Solberg, Timothy D.
    McDonough, James E.
    Simone, Charles B.
    Lin, Liyong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 558 - 572
  • [22] Clinical validation of Monte Carlo dose calculation for pencil beam scanning proton therapy.
    Widesott, L.
    Lorentini, S.
    Fracchiolla, F.
    Farace, P.
    Schwarz, M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S45 - S46
  • [23] Experimental validation of a Monte Carlo proton therapy nozzle model incorporating magnetically steered protons
    Peterson, S. W.
    Polf, J.
    Bues, M.
    Ciangaru, G.
    Archambault, L.
    Beddar, S.
    Smith, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (10): : 3217 - 3229
  • [24] TOPAS Monte Carlo simulation for a scanning proton therapy system in SPHIC
    Chen, Zhi
    Liu, Hongdong
    Zhao, Jingfang
    Kaess, Stefanie
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (01) : 122 - 129
  • [25] Validation of the Monte Carlo model of the passive scattering nozzles at the Proton Therapy Center Houston
    Titt, U.
    Sahoo, N.
    Zhu, R.
    Ding, X.
    Zheng, Y.
    Gillin, M.
    Mohan, R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2503 - 2503
  • [26] Beam Model Interface for Treatment Planning in Proton Therapy Using Macro Monte Carlo
    Fix, M. K.
    Frei, D.
    Volken, W.
    Born, E. J.
    Aebersold, D. M.
    Manser, P.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Validation and Implementation of Proton Pencil Beam Scanning Nozzle Using TOPAS Monte Carlo Simulation
    Lin, C.
    Feng, Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E875 - E875
  • [28] Simulation and experimental benchmarking of a proton pencil beam scanning nozzle model for development of MR-integrated proton therapy
    Oborn, Bradley M.
    Semioshkina, Ekaterina
    van der Kraaij, Erik
    Hoffmann, Aswin L.
    MEDICAL PHYSICS, 2024, 51 (09) : 6196 - 6205
  • [29] Monte Carlo modelling of the treatment line of the Proton Therapy Center in Orsay
    Stankovskiy, A.
    Kerhoas-Cavata, S.
    Ferrand, R.
    Nauraye, C.
    Demarzi, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08): : 2377 - 2394
  • [30] Monte carlo calculations in support of the commissioning of the Northeast Proton Therapy Center
    J. Flanz
    H. Paganetti
    Australasian Physics & Engineering Sciences in Medicine, 2003, 26 (4): : 156 - 161