Diagnostic Accuracy of Dual-Energy CT for Evaluation of Renal Masses: Systematic Review and Meta-Analysis

被引:34
|
作者
Salameh, Jean-Paul [1 ]
McInnes, Matthew D. F. [1 ,2 ]
McGrath, Trevor A. [2 ]
Salameh, Gilles [3 ]
Schieda, Nicola [1 ,2 ]
机构
[1] Univ Ottawa, Sch Epidemiol Publ Hlth & Prevent Med, Ottawa Hosp, Clin Epidemiol Program,Fac Med,Res Inst, Ottawa, ON, Canada
[2] Univ Ottawa, Ottawa Hosp Civ Campus, Dept Radiol, 1053 Carling Ave,Rm c159, Ottawa, ON K1Y 4E9, Canada
[3] Univ Ottawa, Fac Sci, Ottawa, ON, Canada
关键词
kidney neoplasms; meta-analysis; routine diagnostic tests; x-ray CT; CYST PSEUDOENHANCEMENT; IODINE QUANTIFICATION; ANGIOMYOLIPOMA AML; PITFALLS; THRESHOLD; PROTOCOL; PHANTOM; LESIONS; MDCT;
D O I
10.2214/AJR.18.20527
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to determine the diagnostic accuracy of dual-energy CT (DECT) using quantitative iodine concentration in patients with renal masses using histopathologic analysis or follow-up imaging as the reference standard. The secondary objective is to compare the accuracy of DECT (using iodine concentration) to that of conventional CT (using Hounsfield unit measurements). MATERIALS AND METHODS. We searched the MEDLINE, Embase, and Cochrane Central Register of Controlled Trials databases for studies evaluating the accuracy of DECT for renal mass characterization (1947-2018). To be included, studies had to evaluate quantitative iodine concentrations in human patients with indeterminate renal masses. Risk of bias and applicability were assessed using quality assessment of diagnostic accuracy studies-2. A bivariate random-effects model was used to determine pooled sensitivity and specificity. Variability was assessed by subgroup analyses (DECT technique and risk of bias) and metaregression using test type and threshold applied as covariates. RESULTS. Of 201 studies identified, five were included (367 patients). Pooled sensitivity and specificity for DECT were 96.6% (95% CI, 85.9-99.3%) and 95.1% (95% CI, 90.7-97.5%), respectively. Metaregression evaluating the influence of the test type (DECT vs conventional CT) did not identify differences in accuracy (p = 0.06). No differences in accuracy based on risk of bias or DECT technique were identified. Limitations include the small number of studies, most of which were at risk of bias. CONCLUSION. DECT with iodine quantification shows sensitivity and specificity greater than 95% for evaluation of renal masses and may be an alternative to conventional CT for assessment of renal masses. Larger scale trials are needed to corroborate our findings.
引用
收藏
页码:W100 / W105
页数:6
相关论文
共 50 条
  • [41] The diagnostic accuracy of procalcitonin for bacteraemia: a systematic review and meta-analysis
    Hoeboer, S. H.
    van der Geest, P. J.
    Nieboer, D.
    Groeneveld, A. B. J.
    CLINICAL MICROBIOLOGY AND INFECTION, 2015, 21 (05) : 474 - 481
  • [42] Diagnostic Accuracy of the ID Migraine: A Systematic Review and Meta-Analysis
    Cousins, Grainne
    Hijazze, Samira
    Van de Laar, Floris A.
    Fahey, Tom
    HEADACHE, 2011, 51 (07): : 1140 - 1148
  • [43] Diagnostic accuracy for skin cancers: a systematic review and meta-analysis
    Chen, Jennifer
    Fernandez, Kristen
    Reddy, Rasika
    Fadadu, Raj
    Kohn, Michael
    Kim, Mi-Ok
    Wei, Maria
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2023, 89 (03) : AB148 - AB148
  • [44] Diagnostic accuracy of tests for leprosy: a systematic review and meta-analysis
    Gurung, P.
    Gomes, C. M.
    Vernal, S.
    Leeflang, M. M. G.
    CLINICAL MICROBIOLOGY AND INFECTION, 2019, 25 (11) : 1315 - 1327
  • [45] Management of Renal Masses and Localized Renal Cancer: Systematic Review and Meta-Analysis
    Pierorazio, Phillip M.
    Johnson, Michael H.
    Patel, Hiten D.
    Sozio, Stephen M.
    Sharma, Ritu
    Iyoha, Emmanuel
    Bass, Eric B.
    Allaf, Mohamad E.
    JOURNAL OF UROLOGY, 2016, 196 (04): : 989 - 998
  • [46] Diagnostic performance of radiomics in adrenal masses: A systematic review and meta-analysis
    Zhang, Hao
    Lei, Hanqi
    Pang, Jun
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [47] Chest CT for detecting COVID-19: a systematic review and meta-analysis of diagnostic accuracy
    Xu, Buyun
    Xing, Yangbo
    Peng, Jiahao
    Zheng, Zhaohai
    Tang, Weiliang
    Sun, Yong
    Xu, Chao
    Peng, Fang
    EUROPEAN RADIOLOGY, 2020, 30 (10) : 5720 - 5727
  • [48] Chest CT for detecting COVID-19: a systematic review and meta-analysis of diagnostic accuracy
    Buyun Xu
    Yangbo Xing
    Jiahao Peng
    Zhaohai Zheng
    Weiliang Tang
    Yong Sun
    Chao Xu
    Fang Peng
    European Radiology, 2020, 30 : 5720 - 5727
  • [49] Diagnostic Accuracy of MRI for Detection of Papillary Renal Cell Carcinoma: A Systematic Review and Meta-Analysis
    Chiarello, Matthew A.
    Mali, Rahul D.
    Kang, Stella K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (04) : 812 - 821
  • [50] Sensitivity of virtual non-contrast dual-energy CT urogram for detection of urinary calculi: a systematic review and meta-analysis
    Katherine McCoombe
    Karen Dobeli
    Steven Meikle
    Stacey Llewellyn
    Peter Kench
    European Radiology, 2022, 32 : 8588 - 8596