Diagnostic Accuracy of Dual-Energy CT for Evaluation of Renal Masses: Systematic Review and Meta-Analysis

被引:34
|
作者
Salameh, Jean-Paul [1 ]
McInnes, Matthew D. F. [1 ,2 ]
McGrath, Trevor A. [2 ]
Salameh, Gilles [3 ]
Schieda, Nicola [1 ,2 ]
机构
[1] Univ Ottawa, Sch Epidemiol Publ Hlth & Prevent Med, Ottawa Hosp, Clin Epidemiol Program,Fac Med,Res Inst, Ottawa, ON, Canada
[2] Univ Ottawa, Ottawa Hosp Civ Campus, Dept Radiol, 1053 Carling Ave,Rm c159, Ottawa, ON K1Y 4E9, Canada
[3] Univ Ottawa, Fac Sci, Ottawa, ON, Canada
关键词
kidney neoplasms; meta-analysis; routine diagnostic tests; x-ray CT; CYST PSEUDOENHANCEMENT; IODINE QUANTIFICATION; ANGIOMYOLIPOMA AML; PITFALLS; THRESHOLD; PROTOCOL; PHANTOM; LESIONS; MDCT;
D O I
10.2214/AJR.18.20527
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to determine the diagnostic accuracy of dual-energy CT (DECT) using quantitative iodine concentration in patients with renal masses using histopathologic analysis or follow-up imaging as the reference standard. The secondary objective is to compare the accuracy of DECT (using iodine concentration) to that of conventional CT (using Hounsfield unit measurements). MATERIALS AND METHODS. We searched the MEDLINE, Embase, and Cochrane Central Register of Controlled Trials databases for studies evaluating the accuracy of DECT for renal mass characterization (1947-2018). To be included, studies had to evaluate quantitative iodine concentrations in human patients with indeterminate renal masses. Risk of bias and applicability were assessed using quality assessment of diagnostic accuracy studies-2. A bivariate random-effects model was used to determine pooled sensitivity and specificity. Variability was assessed by subgroup analyses (DECT technique and risk of bias) and metaregression using test type and threshold applied as covariates. RESULTS. Of 201 studies identified, five were included (367 patients). Pooled sensitivity and specificity for DECT were 96.6% (95% CI, 85.9-99.3%) and 95.1% (95% CI, 90.7-97.5%), respectively. Metaregression evaluating the influence of the test type (DECT vs conventional CT) did not identify differences in accuracy (p = 0.06). No differences in accuracy based on risk of bias or DECT technique were identified. Limitations include the small number of studies, most of which were at risk of bias. CONCLUSION. DECT with iodine quantification shows sensitivity and specificity greater than 95% for evaluation of renal masses and may be an alternative to conventional CT for assessment of renal masses. Larger scale trials are needed to corroborate our findings.
引用
收藏
页码:W100 / W105
页数:6
相关论文
共 50 条
  • [31] Diagnostic accuracy of 18F-FDG PET or PET/CT for the characterization of adrenal masses: a systematic review and meta-analysis
    Kim, Seong-Jang
    Lee, Sang-Woo
    Pak, Kyoungjune
    Kim, In-Ju
    Kim, Keunyoung
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1086):
  • [32] Diagnostic Accuracy of Multidetector CT in Acute Mesenteric Ischemia: Systematic Review and Meta-Analysis
    Menke, Jan
    RADIOLOGY, 2010, 256 (01) : 93 - 101
  • [33] Diagnostic Accuracy of CT for Local Staging of Colon Cancer: A Systematic Review and Meta-Analysis
    Nerad, Elias
    Lahaye, Max J.
    Maas, Monique
    Nelemans, Patty
    Bakers, Frans C. H.
    Beets, Geerard L.
    Beets-Tan, Regina G. H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (05) : 984 - 995
  • [34] Re: Diagnostic Performance of CT for Diagnosis of Fat-Poor Angiomyolipoma in Patients with Renal Masses: A Systematic Review and Meta-Analysis
    Siegel, Cary
    JOURNAL OF UROLOGY, 2018, 199 (06): : 1376 - 1376
  • [35] Diagnostic accuracy of contrast-enhanced dual-energy computed tomography for detecting metastatic lymph nodes in patients with malignant tumors: a systematic review and meta-analysis
    Kong, Derui
    Chen, Xinyu
    Gao, Peihong
    Zhao, Kexin
    Zheng, Chong
    Zhou, Hongwei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (05) : 3050 - 3065
  • [36] Diagnostic accuracy of dual-energy computed tomography (DECT) to differentiate uric acid from non-uric acid calculi: systematic review and meta-analysis
    Trevor A. McGrath
    Robert A. Frank
    Nicola Schieda
    Brian Blew
    Jean-Paul Salameh
    Patrick M. M. Bossuyt
    Matthew D. F. McInnes
    European Radiology, 2020, 30 : 2791 - 2801
  • [37] Diagnostic test accuracy: methods for systematic review and meta-analysis
    Campbell, Jared M.
    Klugar, Miloslav
    Ding, Sandrine
    Carmody, Dennis P.
    Hakonsen, Sasja J.
    Jadotte, Yuri T.
    White, Sarahlouise
    Munn, Zachary
    INTERNATIONAL JOURNAL OF EVIDENCE-BASED HEALTHCARE, 2015, 13 (03) : 154 - 162
  • [38] Dual-energy CT performance in acute pulmonary embolism: a meta-analysis
    Monti, Caterina B.
    Zanardo, Moreno
    Cozzi, Andrea
    Schiaffino, Simone
    Spagnolo, Pietro
    Secchi, Francesco
    De Cecco, Carlo N.
    Sardanelli, Francesco
    EUROPEAN RADIOLOGY, 2021, 31 (08) : 6248 - 6258
  • [39] Diagnostic accuracy of dual-energy computed tomography (DECT) to differentiate uric acid from non-uric acid calculi: systematic review and meta-analysis
    McGrath, Trevor A.
    Frank, Robert A.
    Schieda, Nicola
    Blew, Brian
    Salameh, Jean-Paul
    Bossuyt, Patrick M. M.
    McInnes, Matthew D. F.
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 2791 - 2801
  • [40] Dual-energy CT performance in acute pulmonary embolism: a meta-analysis
    Caterina B. Monti
    Moreno Zanardo
    Andrea Cozzi
    Simone Schiaffino
    Pietro Spagnolo
    Francesco Secchi
    Carlo N. De Cecco
    Francesco Sardanelli
    European Radiology, 2021, 31 : 6248 - 6258