Diagnostic Accuracy of Dual-Energy CT for Evaluation of Renal Masses: Systematic Review and Meta-Analysis

被引:34
|
作者
Salameh, Jean-Paul [1 ]
McInnes, Matthew D. F. [1 ,2 ]
McGrath, Trevor A. [2 ]
Salameh, Gilles [3 ]
Schieda, Nicola [1 ,2 ]
机构
[1] Univ Ottawa, Sch Epidemiol Publ Hlth & Prevent Med, Ottawa Hosp, Clin Epidemiol Program,Fac Med,Res Inst, Ottawa, ON, Canada
[2] Univ Ottawa, Ottawa Hosp Civ Campus, Dept Radiol, 1053 Carling Ave,Rm c159, Ottawa, ON K1Y 4E9, Canada
[3] Univ Ottawa, Fac Sci, Ottawa, ON, Canada
关键词
kidney neoplasms; meta-analysis; routine diagnostic tests; x-ray CT; CYST PSEUDOENHANCEMENT; IODINE QUANTIFICATION; ANGIOMYOLIPOMA AML; PITFALLS; THRESHOLD; PROTOCOL; PHANTOM; LESIONS; MDCT;
D O I
10.2214/AJR.18.20527
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to determine the diagnostic accuracy of dual-energy CT (DECT) using quantitative iodine concentration in patients with renal masses using histopathologic analysis or follow-up imaging as the reference standard. The secondary objective is to compare the accuracy of DECT (using iodine concentration) to that of conventional CT (using Hounsfield unit measurements). MATERIALS AND METHODS. We searched the MEDLINE, Embase, and Cochrane Central Register of Controlled Trials databases for studies evaluating the accuracy of DECT for renal mass characterization (1947-2018). To be included, studies had to evaluate quantitative iodine concentrations in human patients with indeterminate renal masses. Risk of bias and applicability were assessed using quality assessment of diagnostic accuracy studies-2. A bivariate random-effects model was used to determine pooled sensitivity and specificity. Variability was assessed by subgroup analyses (DECT technique and risk of bias) and metaregression using test type and threshold applied as covariates. RESULTS. Of 201 studies identified, five were included (367 patients). Pooled sensitivity and specificity for DECT were 96.6% (95% CI, 85.9-99.3%) and 95.1% (95% CI, 90.7-97.5%), respectively. Metaregression evaluating the influence of the test type (DECT vs conventional CT) did not identify differences in accuracy (p = 0.06). No differences in accuracy based on risk of bias or DECT technique were identified. Limitations include the small number of studies, most of which were at risk of bias. CONCLUSION. DECT with iodine quantification shows sensitivity and specificity greater than 95% for evaluation of renal masses and may be an alternative to conventional CT for assessment of renal masses. Larger scale trials are needed to corroborate our findings.
引用
收藏
页码:W100 / W105
页数:6
相关论文
共 50 条
  • [1] Diagnostic accuracy of dual-energy CT in gout: a systematic review and meta-analysis
    Zhange Yu
    Tianli Mao
    Yaping Xu
    Tengqi Li
    Yanhua Wang
    Fuqiang Gao
    Wei Sun
    Skeletal Radiology, 2018, 47 : 1587 - 1593
  • [2] Diagnostic accuracy of dual-energy CT in gout: a systematic review and meta-analysis
    Yu, Zhange
    Mao, Tianli
    Xu, Yaping
    Li, Tengqi
    Wang, Yanhua
    Gao, Fuqiang
    Sun, Wei
    SKELETAL RADIOLOGY, 2018, 47 (12) : 1587 - 1593
  • [3] Diagnostic Accuracy of Dual-Energy CT in Detection of Acute Pulmonary Embolism: A Systematic Review and Meta-Analysis
    Abdellatif, Waleed
    Ebada, Mahmoud Ahmed
    Alkanj, Souad
    Negida, Ahmed
    Murray, Nicolas
    Khosa, Faisal
    Nicolaou, Savvas
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2021, 72 (02): : 285 - 292
  • [4] Systematic Review and Meta-Analysis Investigating the Diagnostic Yield of Dual-Energy CT for Renal Mass Assessment
    Bellini, Davide
    Panvini, Nicola
    Laghi, Andrea
    Marin, Daniele
    Patel, Bhavik N.
    Wang, Carolyn L.
    Carbone, Iacopo
    Mileto, Achille
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (05) : 1044 - 1053
  • [5] Diagnostic accuracy of dual-energy CT for the detection of bone marrow edema in the appendicular skeleton: a systematic review and meta-analysis
    Mitchell P. Wilson
    Kevin Lui
    Dorian Nobbee
    Mohammad H. Murad
    Matthew D. F. McInnes
    Trevor A. McGrath
    Prayash Katlariwala
    Gavin Low
    European Radiology, 2021, 31 : 1558 - 1568
  • [6] Diagnostic accuracy of dual-energy CT for the detection of bone marrow edema in the appendicular skeleton: a systematic review and meta-analysis
    Wilson, Mitchell P.
    Lui, Kevin
    Nobbee, Dorian
    Murad, Mohammad H.
    McInnes, Matthew D. F.
    McGrath, Trevor A.
    Katlariwala, Prayash
    Low, Gavin
    EUROPEAN RADIOLOGY, 2021, 31 (03) : 1558 - 1568
  • [7] Diagnostic Accuracy of MRI for Solid Renal Masses: A Systematic Review and Meta-analysis
    Frank, Robert A.
    Dawit, Haben
    Bossuyt, Patrick M. M.
    Leeflang, Mariska
    Flood, Trevor A.
    Breau, Rodney H.
    McInnes, Matthew D. F.
    Schieda, Nicola
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (04) : 1172 - 1184
  • [8] Diagnostic accuracy of dual-energy CT for bone marrow edema in patients with acute knee injury: a systematic review and meta-analysis
    Zhizhuo Li
    Xuelong Chen
    Hui Fang
    Chengxin Li
    Lijun Shi
    Xiaoyu Fan
    Xin Xu
    Fuqiang Gao
    Wei Sun
    Jiang Qing
    Journal of Orthopaedic Surgery and Research, 18
  • [9] Diagnostic accuracy of dual-energy CT for bone marrow edema in patients with acute knee injury: a systematic review and meta-analysis
    Li, Zhizhuo
    Chen, Xuelong
    Fang, Hui
    Li, Chengxin
    Shi, Lijun
    Fan, Xiaoyu
    Xu, Xin
    Gao, Fuqiang
    Sun, Wei
    Qing, Jiang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [10] Diagnostic performance of dual-energy CT for the detection of bone marrow oedema: a systematic review and meta-analysis
    Chong Hyun Suh
    Seong Jong Yun
    Wook Jin
    Sun Hwa Lee
    So Young Park
    Chang-Woo Ryu
    European Radiology, 2018, 28 : 4182 - 4194