Accuracy of radiotherapy dose calculations based on cone-beam CT: comparison of deformable registration and image correction based methods

被引:37
|
作者
Marchant, T. E. [1 ,2 ]
Joshi, K. D. [2 ]
Moore, C. J. [1 ]
机构
[1] Univ Manchester, Christie NHS Fdn Trust, Manchester Acad Hlth Sci Ctr, Manchester M20 4BX, Lancs, England
[2] Christie NHS Fdn Trust, Christie Med Phys & Engn, Manchester M20 4BX, Lancs, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 06期
基金
英国医学研究理事会;
关键词
cone-beam CT; image guided radiotherapy; deformable image registration; GUIDED RADIATION-THERAPY; SHADING CORRECTION; ADAPTIVE RADIOTHERAPY; COMPUTED-TOMOGRAPHY; CBCT; SCATTER;
D O I
10.1088/1361-6560/aab0f0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radiotherapy dose calculations based on cone-beam CT (CBCT) images can be inaccurate due to unreliable Hounsfield units (HU) in the CBCT. Deformable image registration of planning CT images to CBCT, and direct correction of CBCT image values are two methods proposed to allow heterogeneity corrected dose calculations based on CBCT. In this paper we compare the accuracy and robustness of these two approaches. CBCT images for 44 patients were used including pelvis, lung and head & neck sites. CBCT HU were corrected using a 'shading correction' algorithm and via deformable registration of planning CT to CBCT using either Elastix or Niftyreg. Radiotherapy dose distributions were re-calculated with heterogeneity correction based on the corrected CBCT and several relevant dose metrics for target and OAR volumes were calculated. Accuracy of CBCT based dose metrics was determined using an 'override ratio' method where the ratio of the dose metric to that calculated on a bulk-density assigned version of the same image is assumed to be constant for each patient, allowing comparison to the patient's planning CT as a gold standard. Similar performance is achieved by shading corrected CBCT and both deformable registration algorithms, with mean and standard deviation of dose metric error less than 1% for all sites studied. For lung images, use of deformed CT leads to slightly larger standard deviation of dose metric error than shading corrected CBCT with more dose metric errors greater than 2% observed (7% versus 1%).
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Comparison of Correction Methods for Dose Computation Using Cone-Beam CT Images
    Lazos, D.
    Furhang, E.
    Kim, C.
    Hu, K.
    Ennis, R.
    Harrison, L.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [22] Evaluation of a CT to cone-beam CT deformable registration algorithm
    Piper, J. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S418 - S419
  • [23] Effects of cone-beam CT noise and cupping artifacts on deformable image registration
    Murphy, M.
    Lu, L.
    Crimaldi, A.
    Cuttino, L.
    Shield, C.
    Keall, P.
    Siebers, J.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 1996 - 1996
  • [24] GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration
    Sharp, G. C.
    Kandasamy, N.
    Singh, H.
    Folkert, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : 5771 - 5783
  • [25] Evaluation of the Performance of a New Deformable Image Registration Algorithms Based On Motion Modeling for Cone-Beam CT Images
    Alsbou, N.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2017, 44 (06) : 3212 - 3213
  • [26] Increasing the Accuracy of Dose Calculation On Cone-Beam Imaging Using Deformable Image Registration in the Case of Prostate Translation
    Fillion, O.
    Gingras, L.
    Archambault, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 402 - 402
  • [27] Image-based deformable motion compensation for interventional cone-beam CT
    Sisniega, A.
    Capostagno, S.
    Zbijewski, W.
    Weiss, C. R.
    Ehtiati, T.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [28] Quantifying the accuracy of deformable image registration for cone-beam computed tomography with a physical phantom
    Wu, Richard Y.
    Liu, Amy Y.
    Williamson, Tyler D.
    Yang, Jinzhong
    Wisdom, Paul G.
    Zhu, Xiaorong R.
    Frank, Steven J.
    Fuller, Clifton D.
    Gunn, Gary B.
    Gao, Song
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 92 - 100
  • [29] Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy
    Wu, T. -H.
    Liang, C. -H.
    Wu, J. -K.
    Lien, C. -Y.
    Yang, B. -H.
    Huang, Y. -H.
    Lee, J. J. S.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [30] Converting Cone-Beam CT to In-Room Conventional CT by a Deformable Image Registration Method
    Zhang, Y.
    Yang, J.
    Zhang, L.
    Dong, L.
    MEDICAL PHYSICS, 2009, 36 (06) : 2477 - +