Reliability of Early Postoperative Radiographic Assessment of Tunnel Placement After Anterior Cruciate Ligament Reconstruction

被引:17
|
作者
Warme, Bryan A. [1 ]
Ramme, Austin J.
Willey, Michael C. [1 ]
Britton, Carla L. [1 ]
Flint, John H. [1 ]
Amendola, Annunziato S. [1 ]
Wolf, Brian R. [1 ]
机构
[1] Univ Iowa Hosp & Clin, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USA
关键词
ACL RECONSTRUCTION; SURGERY EXPERIENCE; GRAFT PLACEMENT; REVISION; ENLARGEMENT; POSITION;
D O I
10.1016/j.arthro.2011.12.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To evaluate the interobserver and intraobserver reliability of radiographic assessment of tunnel placement in anterior cruciate ligament reconstruction. Methods: Seven sports fellowship-trained orthopaedic surgeons in the Multicenter Orthopaedic Outcomes Network (MOON) group participated in the study. We prospectively enrolled 54 consecutive patients after primary anterior cruciate ligament reconstruction. Postoperative plain radiographs were obtained including a full-extension anteroposterior view of the knee, a lateral view of the knee in full extension, and a notch view at 45 degrees of flexion (Rosenberg view). Three blinded reviewers performed 8 different radiographic measurements including those of Harner and Aglietti/Jonsson. Intraclass correlation coefficients were used to determine reliability of the measurements. Intrarater reliability was assessed by repeated measurements of a subset of 20 patient images from 1 institution, and inter-rater reliability was assessed by use of all 54 sets of films from a total of 4 institutions. Results: Intraobserver reliability for femoral measures ranged from none to substantial, with notch height having the worst results. Intraobserver reliability was moderate to almost perfect for tibial measures. Interobserver reliability ranged from slight to moderate for femoral measures. The Harner method for determining tunnel depth was more reliable than the Aglietti/Jonsson method. Interobserver reliability for tibial measures ranged from fair to substantial. The presence of metal interference screws did not improve reliability of measurements. Conclusions: Postoperative radiographs are easily obtained, but our results show that radiographic measurements are of quite variable reliability, with most of the results falling into the fair to moderate categories. Level of Evidence: Level III, diagnostic study.
引用
收藏
页码:942 / 951
页数:10
相关论文
共 50 条
  • [41] Outcomes of postoperative septic arthritis after anterior cruciate ligament reconstruction
    McAllister, DR
    Parker, RD
    Cooper, AE
    Recht, MP
    Abate, J
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (05): : 562 - 570
  • [42] Femoral tunnel placement in anterior cruciate ligament reconstruction: Rationale of the two incision technique
    Garofalo R.
    Moretti B.
    Kombot C.
    Moretti L.
    Mouhsine E.
    Journal of Orthopaedic Surgery and Research, 2 (1)
  • [43] Radiographic description of femoral tunnel placement expressed as intercondylar clock time in double-bundle anterior cruciate ligament reconstruction
    Junya Yamazaki
    Takeshi Muneta
    Hideyuki Koga
    Ichiro Sekiya
    Young-Jin Ju
    Toshiyuki Morito
    Kazuyoshi Yagishita
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 418 - 423
  • [44] Radiographic description of femoral tunnel placement expressed as intercondylar clock time in double-bundle anterior cruciate ligament reconstruction
    Yamazaki, Junya
    Muneta, Takeshi
    Koga, Hideyuki
    Sekiya, Ichiro
    Ju, Young-Jin
    Morito, Toshiyuki
    Yagishita, Kazuyoshi
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (03) : 418 - 423
  • [45] Evaluating the Accuracy of Tibial Tunnel Placement After Anatomic Single-Bundle Anterior Cruciate Ligament Reconstruction
    Pedneault, Christopher
    Laverdiere, Carl
    Hart, Adam
    Boily, Mathieu
    Burman, Mark
    Martineau, Paul A.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (13): : 3187 - 3194
  • [46] Femoral interference screw placement through the tibial tunnel: A radiographic evaluation of interference screw divergence angles after endoscopic anterior cruciate ligament reconstruction
    Brodie, JT
    Torpey, BM
    Donald, GD
    Bade, HA
    ARTHROSCOPY, 1996, 12 (04): : 435 - 440
  • [47] Radiodense ligament markers for radiographic evaluation of anterior cruciate ligament reconstruction
    Borbas, Paul
    Wieser, Karl
    Rahm, Stefan
    Fucentese, Sandro F.
    Koch, Peter P.
    Meyer, Dominik C.
    KNEE, 2014, 21 (06): : 1018 - 1022
  • [48] Reliability and Reproducibility of Several Methods of Arthroscopic Assessment of Femoral Tunnel Position During Anterior Cruciate Ligament Reconstruction
    Ilahi, Omer A.
    Mansfield, David J.
    Urrea, Luis H., II
    Qadeer, Ali A.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (10): : 1303 - 1310
  • [49] Radiographic evaluation of native anterior cruciate ligament attachments and graft placement for reconstruction - A cadaveric study
    Lintner, DM
    Dewitt, SE
    Moseley, JB
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (01): : 72 - 78
  • [50] BONE TUNNEL ENLARGEMENT ON ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION
    de Aguiar Leonardi, Adriano Barros
    Duarte Junior, Aires
    Severino, Nilson Roberto
    ACTA ORTOPEDICA BRASILEIRA, 2014, 22 (05): : 240 - 244