Reliability of Early Postoperative Radiographic Assessment of Tunnel Placement After Anterior Cruciate Ligament Reconstruction

被引:17
|
作者
Warme, Bryan A. [1 ]
Ramme, Austin J.
Willey, Michael C. [1 ]
Britton, Carla L. [1 ]
Flint, John H. [1 ]
Amendola, Annunziato S. [1 ]
Wolf, Brian R. [1 ]
机构
[1] Univ Iowa Hosp & Clin, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USA
关键词
ACL RECONSTRUCTION; SURGERY EXPERIENCE; GRAFT PLACEMENT; REVISION; ENLARGEMENT; POSITION;
D O I
10.1016/j.arthro.2011.12.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To evaluate the interobserver and intraobserver reliability of radiographic assessment of tunnel placement in anterior cruciate ligament reconstruction. Methods: Seven sports fellowship-trained orthopaedic surgeons in the Multicenter Orthopaedic Outcomes Network (MOON) group participated in the study. We prospectively enrolled 54 consecutive patients after primary anterior cruciate ligament reconstruction. Postoperative plain radiographs were obtained including a full-extension anteroposterior view of the knee, a lateral view of the knee in full extension, and a notch view at 45 degrees of flexion (Rosenberg view). Three blinded reviewers performed 8 different radiographic measurements including those of Harner and Aglietti/Jonsson. Intraclass correlation coefficients were used to determine reliability of the measurements. Intrarater reliability was assessed by repeated measurements of a subset of 20 patient images from 1 institution, and inter-rater reliability was assessed by use of all 54 sets of films from a total of 4 institutions. Results: Intraobserver reliability for femoral measures ranged from none to substantial, with notch height having the worst results. Intraobserver reliability was moderate to almost perfect for tibial measures. Interobserver reliability ranged from slight to moderate for femoral measures. The Harner method for determining tunnel depth was more reliable than the Aglietti/Jonsson method. Interobserver reliability for tibial measures ranged from fair to substantial. The presence of metal interference screws did not improve reliability of measurements. Conclusions: Postoperative radiographs are easily obtained, but our results show that radiographic measurements are of quite variable reliability, with most of the results falling into the fair to moderate categories. Level of Evidence: Level III, diagnostic study.
引用
收藏
页码:942 / 951
页数:10
相关论文
共 50 条
  • [31] Tunnel placement in anterior cruciate reconstruction - Reply
    Anderson, AF
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (03): : 647 - 648
  • [32] Avoiding Posterior Cruciate Ligament and Roof Impingement With Transtibial Anterior Cruciate Ligament Reconstruction: Keys to Correct Tunnel Placement
    Matsumoto, Akio
    Howell, Stephen M.
    TECHNIQUES IN ORTHOPAEDICS, 2005, 20 (03) : 211 - 217
  • [33] Tibial tunnel enlargement after arthroscopic anterior cruciate ligament reconstruction
    Majewski, M
    Schulte, KR
    Harner, CD
    SPORTVERLETZUNG-SPORTSCHADEN, 2002, 16 (01) : 22 - 25
  • [34] Reliability of Tunnel Measurements and the Quadrant Method Using Fluoroscopic Radiographs After Anterior Cruciate Ligament Reconstruction
    Sullivan, Jaron P.
    Matava, Matthew J.
    Flanigan, David C.
    Gao, Yubo
    Britton, Carla L.
    Amendola, Annunziato
    Wolf, Brian R.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (10): : 2236 - 2241
  • [35] Radiographic evaluation of anterior cruciate ligament graft failure with special reference to tibial tunnel placement
    Almekinders, LC
    Chiavetta, JB
    Clarke, JP
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1998, 14 (02): : 206 - 211
  • [36] Postoperative Infection after Anterior Cruciate Ligament Reconstruction: Prevention and Management
    Komnos, George A.
    Chalatsis, George
    Mitrousias, Vasilios
    Hantes, Michael E.
    MICROORGANISMS, 2022, 10 (12)
  • [37] Postoperative Rehabilitation and Return to Play After Anterior Cruciate Ligament Reconstruction
    Panariello, Robert A.
    Stump, Timothy J.
    Maddalone, Dean
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2016, 24 (01) : 35 - 44
  • [38] Drill tunnel placement in anterior cruciate ligament reconstruction. Position misplacement anatometrics
    Csizy, M
    Friederich, NF
    ORTHOPADE, 2002, 31 (08): : 741 - 750
  • [39] Tunnel placement in anterior cruciate ligament (ACL) reconstruction: quality control in a teaching hospital
    H. Behrend
    G. Stutz
    M. A. Kessler
    A. Rukavina
    K. Giesinger
    M. S. Kuster
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 1159 - 1165
  • [40] Tunnel placement in anterior cruciate ligament (ACL) reconstruction: quality control in a teaching hospital
    Behrend, H.
    Stutz, G.
    Kessler, M. A.
    Rukavina, A.
    Giesinger, K.
    Kuster, M. S.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (11) : 1159 - 1165