Pulse oximeters' reliability in detecting hypoxemia and bradycardia: Comparison between a conventional and two new generation oximeters

被引:70
|
作者
Bohnhorst, B [1 ]
Peter, CS [1 ]
Poets, CF [1 ]
机构
[1] Hannover Med Sch, Dept Neonatol & Pediat Pulmonol, D-3000 Hannover, Germany
关键词
arterial oxygen saturation; neonatal intensive care; preterm infants; pulse oximetry; sudden infant death syndrome;
D O I
10.1097/00003246-200005000-00050
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Pulse oximeters are increasingly used for patient monitoring; however, they are traditionally very prone to motion artifact. Newly developed instruments have lower false alarm rates. We wanted to know whether this is achieved at the expense of an increased proportion of false negative alarms such as missed or delayed identification of hypoxemia and/or bradycardia. Design: Observational study. Setting: Neonatal intensive care unit. Patients: A total of 17 unsedated preterm infants (median gestational age at birth, 25 wks; range, 24-30 wks). Intervention: Long-term recordings of transcutaneous partial pressure of oxygen (P-ToO2), heart rate, pulse oximeter saturation (Sp(O2)), and pulse rate from a conventional oximeter and two new generation oximeters. Measurements: Recordings were analyzed for episodes with P-TcO2 < 40 torr or with heart rate <80 beats/min for >5 sees. Hypoxemia was considered identified if Sp(O2) had fallen to <85% within 2 mins of P-TcO2 reaching 40 torr, and bradycardia was considered identified if pulse rate had fallen to <80 beats/min within 2 mins of the heart rate reaching this threshold. Main Results: A total of 202 falls in P-TcO2 to <40 torr occurred; 174 (86%) were identified by all three oximeters. Of the remaining episodes, manual analysis of red and infrared absorption signals confirmed that Sp(O2) had indeed been <85% for greater than or equal to 10 sees in 11 episodes; therefore, these episodes should have been identified by all three oximeters. None of these had been missed by the conventional oximeter, but 10 (5.4% of the total) were missed by one of the new generation instruments (Nellcor), and one (0.5%) was missed by the other (Masimo). Of 54 bradycardias, only 14 were identified by all three oximeters; 17 (32%) were missed by the conventional, 37 (69%) by the Nellcor, and 4 (7%) by the Masimo instrument. Conclusion: One of the two new generation instruments investigated in this study missed 5.4% of hypoxemic episodes and 69% of bradycardias. It thus appears that this instrument's reduced false alarm rate is achieved at the expense of an unreliable and/or delayed identification of hypoxemia and bradycardia. The other instrument identified both conditions equally as or more reliably than a conventional pulse oximeter.
引用
收藏
页码:1565 / 1568
页数:4
相关论文
共 47 条
  • [41] Comparison between monocycle and two-cycle pumpings for the high-order harmonic attosecond-pulse generation
    Fang, Shaobo
    Tanigawa, T.
    Ishikawa, K.
    Karasawa, N.
    Yamashita, M.
    2009 LASERS & ELECTRO-OPTICS & THE PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1 AND 2, 2009, : 57 - +
  • [42] New-generation pulse oximetry for the assessment of peripheral perfusion during general anaesthesia - a comparison between propofol and desflurane
    Kowalczyk, Michal
    Fijalkowska, Anna
    Nestorowicz, Andrzej
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2013, 45 (03) : 138 - 144
  • [43] Comparison between new-generation SiPM-based and conventional PMT-based TOF-PET/CT
    Wagatsuma, Kei
    Miwa, Kenta
    Sakata, Muneyuki
    Oda, Keiichi
    Ono, Haruka
    Kameyama, Masashi
    Toyohara, Jun
    Ishii, Kenji
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 : 203 - 210
  • [44] Comparison in Short-Term Safety and Efficacy between New-Generation WATCHMAN FLX and Conventional WATCHMAN 2.5 for Percutaneous Left Atrial Appendage Closure
    Fukuda, Nobuyuki
    Imamura, Teruhiko
    Tanaka, Shuhei
    Kataoka, Naoya
    Ushijima, Ryuichi
    Ueno, Hiroshi
    Kinugawa, Koichiro
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (06)
  • [45] FDG-uptake in adrenal glands; Comparison between new-generation Silicon Photomultiplier (SiPM) -based PET/CT with respiratory synchronization and conventional PET/CT
    Toyama, Y.
    Takanami, K.
    Kagaya, Y.
    Saito, M.
    Takase, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S713 - S714
  • [46] Comparison of Stent-Related Symptoms Between Conventional Double-J Stents and a New-Generation Thermoexpandable Segmental Metallic Stent: A Validated-Questionnaire-Based Study
    Maan, Zafar
    Patel, Dharmesh
    Moraitis, Konstantinos
    El-Husseiny, Tamer
    Papatsoris, Athanasios G.
    Buchholz, Niels-Peter
    Masood, Junaid
    JOURNAL OF ENDOUROLOGY, 2010, 24 (04) : 589 - 593
  • [47] Clinical, Angiographic, And Intravascular Ultrasound Impact Of New Generation Dedicated Stents To The Treatment Of Saphenous Vein Grafts - Comparison Between Two"First-In-Human"Series : Mguard™ And Sesame™
    Mendes, Alaor
    Costa, J. Ribamar
    Lima, Andre
    Costa, Ricardo
    Abizaid, Andrea Sousa
    Feres, Fausto
    Sousa, Amanda
    Sousa, J. Eduardo
    Abizaid, Alexandre Cunha
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 181I - 181I