Pulse oximeters' reliability in detecting hypoxemia and bradycardia: Comparison between a conventional and two new generation oximeters

被引:70
|
作者
Bohnhorst, B [1 ]
Peter, CS [1 ]
Poets, CF [1 ]
机构
[1] Hannover Med Sch, Dept Neonatol & Pediat Pulmonol, D-3000 Hannover, Germany
关键词
arterial oxygen saturation; neonatal intensive care; preterm infants; pulse oximetry; sudden infant death syndrome;
D O I
10.1097/00003246-200005000-00050
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Pulse oximeters are increasingly used for patient monitoring; however, they are traditionally very prone to motion artifact. Newly developed instruments have lower false alarm rates. We wanted to know whether this is achieved at the expense of an increased proportion of false negative alarms such as missed or delayed identification of hypoxemia and/or bradycardia. Design: Observational study. Setting: Neonatal intensive care unit. Patients: A total of 17 unsedated preterm infants (median gestational age at birth, 25 wks; range, 24-30 wks). Intervention: Long-term recordings of transcutaneous partial pressure of oxygen (P-ToO2), heart rate, pulse oximeter saturation (Sp(O2)), and pulse rate from a conventional oximeter and two new generation oximeters. Measurements: Recordings were analyzed for episodes with P-TcO2 < 40 torr or with heart rate <80 beats/min for >5 sees. Hypoxemia was considered identified if Sp(O2) had fallen to <85% within 2 mins of P-TcO2 reaching 40 torr, and bradycardia was considered identified if pulse rate had fallen to <80 beats/min within 2 mins of the heart rate reaching this threshold. Main Results: A total of 202 falls in P-TcO2 to <40 torr occurred; 174 (86%) were identified by all three oximeters. Of the remaining episodes, manual analysis of red and infrared absorption signals confirmed that Sp(O2) had indeed been <85% for greater than or equal to 10 sees in 11 episodes; therefore, these episodes should have been identified by all three oximeters. None of these had been missed by the conventional oximeter, but 10 (5.4% of the total) were missed by one of the new generation instruments (Nellcor), and one (0.5%) was missed by the other (Masimo). Of 54 bradycardias, only 14 were identified by all three oximeters; 17 (32%) were missed by the conventional, 37 (69%) by the Nellcor, and 4 (7%) by the Masimo instrument. Conclusion: One of the two new generation instruments investigated in this study missed 5.4% of hypoxemic episodes and 69% of bradycardias. It thus appears that this instrument's reduced false alarm rate is achieved at the expense of an unreliable and/or delayed identification of hypoxemia and bradycardia. The other instrument identified both conditions equally as or more reliably than a conventional pulse oximeter.
引用
收藏
页码:1565 / 1568
页数:4
相关论文
共 47 条
  • [31] Reply to "'New-Generation' Pulse Oximeters in Extremely Low-Birth-Weight Infants"
    O'Reilly, Michael
    JOURNAL OF PERINATAL & NEONATAL NURSING, 2012, 26 (04) : 282 - 283
  • [32] Monitoring oxygen saturation and heart rate during neonatal transition. comparison between two different pulse oximeters and electrocardiography
    Rasha Khoury
    Gil Klinger
    Yakir Shir
    Michael Osovsky
    Ruben Bromiker
    Journal of Perinatology, 2021, 41 : 885 - 890
  • [33] Monitoring oxygen saturation and heart rate during neonatal transition. comparison between two different pulse oximeters and electrocardiography
    Khoury, Rasha
    Klinger, Gil
    Shir, Yakir
    Osovsky, Michael
    Bromiker, Ruben
    JOURNAL OF PERINATOLOGY, 2021, 41 (04) : 885 - 890
  • [34] Comparison of three new technology pulse oximeters during recovery from extreme exercise in adult males
    Witucki, PJ
    Bell, SJ
    CRITICAL CARE MEDICINE, 1999, 27 (12) : A87 - A87
  • [35] Comparison of two types of pulse-oximeters during low perfusion and increased motion artifact in pediatric patients.
    Downs, Ben
    Willis, Randy
    Heulitt, Mark
    CRITICAL CARE MEDICINE, 2006, 34 (12) : A89 - A89
  • [36] "New-Generation" Pulse Oximeters in Extremely Low-Birth-Weight Infants How Do They Perform in Clinical Practice?
    van der Eijk, Anne C.
    Horsch, Sandra
    Eilers, Paul H. C.
    Dankelman, Jenny
    Smit, Bert J.
    JOURNAL OF PERINATAL & NEONATAL NURSING, 2012, 26 (02) : 172 - 180
  • [38] A comparison between two NIRS oximeters (INVOS, OxyPrem) using measurement on the arm of adults and head of infants after caesarean section
    Hyttel-Sorensen, Simon
    Hessel, Trine Witzner
    la Cour, Amalia
    Greisen, Gorm
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (10): : 3671 - 3683
  • [39] Comparison between conventional Si and new generation of SiC detector for high proton energy spectrometry
    Torrisi, L.
    Havranek, V.
    Mackova, A.
    Calcagno, L.
    Torrisi, A.
    Cutroneo, M.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (04):
  • [40] A comparison between a conventional medium and a new generation of sequential media (GIII) for transfer of early cleavage stage embryos
    Westin, C.
    Borg, K.
    Hillensjo, T.
    Jakobsson, A. -H
    Olofsson, J.
    Reismer, E.
    Wennerstrom, S.
    Wikland, M.
    Wood, M.
    HUMAN REPRODUCTION, 2003, 18 : 151 - 151