Intraoperative 3D imaging of the facial skeleton using the SIREMOBIL Iso-C3D

被引:61
|
作者
Heiland, M
Schmelzle, R
Hebecker, A
Schulze, D
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Oral & Maxillofacial Surg, D-20246 Hamburg, Germany
[2] Siemens AG, Med Solut, D-8520 Erlangen, Germany
[3] Univ Hamburg, Hosp Eppendorf, Dept Oral Radiol, D-20246 Hamburg, Germany
关键词
fluoroscopy; cone beam computed tomography; intraoperative 3D imaging; facial skeleton;
D O I
10.1259/dmfr/15309653
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: With respect to high-contrast structures, cone beam computed tomography (CBCT) offers an alternative imaging modality to computed tomography (CT), requiring less radiation exposure. The C-arm system SIREMOBIL Iso-C-3D for three-dimensional (3D) reconstruction has made this modality available for intraoperative use. This paper presents the first intraoperative images of the facial skeleton using the SIREMOBIL Iso-C-3D. Methods: Cases of a zygomaticomaxillary complex fracture, a mandibular angle fracture and a bimaxillary repositioning osteotomy are described to demonstrate the application possibilities of this system in maxillofacial surgery. Results: In addition to the uncomplicated handling of the SIREMOBIL Iso-C-3D, generally important was the low level of metal artefacts in its primary and secondary reconstructions, even in close proximity to the material. However, it has to be kept in mind that while soft tissues are visualized using CBCT, information about soft tissue quality cannot be obtained. Conclusion: The SIREMOBIL Iso-C-3D generates intraoperative data sets suitable for the visualization of the facial bones after open reduction of fractures.
引用
收藏
页码:130 / 132
页数:3
相关论文
共 50 条
  • [21] Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm system
    Heiland, M
    Schulze, D
    Blake, F
    Schmelzle, R
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (04) : 369 - 375
  • [22] 3D FaceCam™ -: A fast and accurate 3D facial imaging device for biometrics applications
    Geng, J
    Zhuang, P
    May, P
    Yi, S
    Tunnell, D
    [J]. BIOMETRIC TECHNOLOGY FOR HUMAN IDENTIFICATION, 2004, 5404 : 316 - 327
  • [23] Intraoperative 3D C-arm imaging. State of the art
    von Recum, J.
    Wendl, K.
    Vock, B.
    Gruetzner, P. A.
    Franke, J.
    [J]. UNFALLCHIRURG, 2012, 115 (03): : 196 - 201
  • [24] Analysis and retrieval of 3D facial models using iso-geodesic stripes
    Berretti, Stefano
    Del Bimbo, Alberto
    Pala, Pietro
    [J]. 2008 INTERNATIONAL WORKSHOP ON CONTENT-BASED MULTIMEDIA INDEXING, 2008, : 241 - 248
  • [25] A 3D Skeletonization Algorithm for 3D Mesh Models Using a Partial Parallel 3D Thinning Algorithm and 3D Skeleton Correcting Algorithm
    Jin, Xun
    Kim, Jongweon
    [J]. APPLIED SCIENCES-BASEL, 2017, 7 (02):
  • [26] Intraoperative Measurement of the Tricuspid Annulus: To 3D or not to 3D?
    Chacon, M. Megan
    Neuburger, Peter J.
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (01) : 146 - 148
  • [27] A METHOD FOR MANUFACTURING SKELETON MODELS USING 3D SCANNING COMBINED WITH 3D PRINTING
    Serban, Ionel
    Rosca, Ileana
    Druga, Corneliu
    [J]. ANNALS OF DAAAM FOR 2009 & PROCEEDINGS OF THE 20TH INTERNATIONAL DAAAM SYMPOSIUM, 2009, 20 : 1319 - 1320
  • [28] 3D FACIAL EXPRESSION ANALYSIS BY USING 2D AND 3D WAVELET TRANSFORMS
    Pinto, S. C. D.
    Mena-Chalco, J. P.
    Lopes, F. M.
    Velho, L.
    Cesar Junior, R. M.
    [J]. 2011 18TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2011, : 1281 - 1284
  • [29] 3D facial and lento-alveolar imaging
    Freezer, Simon
    Fricker, John
    [J]. AUSTRALASIAN ORTHODONTIC JOURNAL, 2017, : 73 - 86
  • [30] ISO-C3D导航下脊柱后路手术患者的手术配合
    郭翠娇
    刘莉
    [J]. 护理学报, 2007, (05) : 61 - 62