Evaluation of Three-Axis Magnetic Loop Antenna Cross Coupling for Low-Frequency Measurements

被引:0
|
作者
Pokotilov, Denys [1 ]
Vogt-Ardatjew, Robert [1 ]
Leferink, Frank [1 ,2 ]
机构
[1] Univ Twente, Enschede, Netherlands
[2] Thales Nederland BV, Hengelo, Netherlands
基金
欧盟地平线“2020”;
关键词
Three-axis antenna; EMI measurements; multichannel; coupling; low-frequency measurements;
D O I
10.1109/EMCSI39492.2022.9889631
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nowadays the majority of electrical devices are complex systems with different operation modes and switching elements. The amount of evaluation procedures that are needed to be done for these devices increases drastically. It is pushing standard radiated EMI measurements to the edge, where the advantage between time and the accuracy of measurements should be chosen. Standard low-frequency measurements as CISPR 36, used to evaluate radiated EMI for frequencies below 30 MHz, became too time-consuming and expensive. Proposed improvements which include time-domain multichannel measurements in combination with a three-axis shielded loop antenna can be more time-efficient. Compared to a conventional single-loop antenna, one of the potential challenges is the coupling between loops for the two- and three-axis antenna. This paper investigates the effect of coupling between the individual loops when illuminated with a complex field, which is shown to be the worst-case scenario. Only some minor coupling is observed implying that such a three-axis loop antenna can be used without sacrificing much accuracy, while still providing a significant improvement in the measurement time-efficiency.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 50 条
  • [31] Spatiotemporal evaluation of human colon motility using three-axis fluxgates and magnetic markers
    Córdova-Fraga, T
    Carneiro, AAO
    de Araujo, DB
    Oliveira, RB
    Sosa, M
    Baffa, O
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (06) : 712 - 715
  • [32] Spatiotemporal evaluation of human colon motility using three-axis fluxgates and magnetic markers
    T. Córdova-Fraga
    A. A. O. Carneiro
    D. B. de Araujo
    R. B. Oliveira
    M. Sosa
    O. Baffa
    Medical and Biological Engineering and Computing, 2005, 43 : 712 - 715
  • [33] Fluxgate magnetometer for low-frequency magnetic electromagnetic compatibility measurements
    Weyand, K
    Bosse, V
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (02) : 617 - 620
  • [34] Array strategy enhances low-frequency radiation intensity and low-frequency magnetic field sensing SNR of magnetoelectric antenna
    Wang, Yinan
    Zi, Guohao
    Song, Enzhong
    Wang, Yuanhang
    Zhao, Shanlin
    Ma, Zhibo
    AIP ADVANCES, 2024, 14 (07)
  • [35] Qubit decoherence under two-axis coupling to low-frequency noises
    Ramon, Guy
    Cywinski, Lukasz
    PHYSICAL REVIEW B, 2022, 105 (04)
  • [36] Evaluation of Numerical Methods for the Simulation of Real Test Facilities for Low-Frequency Magnetic Fields Measurements
    Rogowski, Maik
    Fisahn, Sven
    Garbe, Heyno
    2018 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2018, : 117 - 121
  • [37] Low-Frequency Magnetic Shielding of Planar Screens: Effects of Loop Radius and Loop-to-Loop Distance
    Qin, Dingyu
    Jiao, Chongqing
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2022, 64 (02) : 367 - 377
  • [38] Electrophysiological Low-Frequency Coherence and Cross-Frequency Coupling Contribute to BOLD Connectivity
    Wang, Liang
    Saalmann, Yuri B.
    Pinsk, Mark A.
    Arcaro, Michael J.
    Kastner, Sabine
    NEURON, 2012, 76 (05) : 1010 - 1020
  • [39] Low-frequency transient electric and magnetic fields coupling to child body
    Ozen, S.
    RADIATION PROTECTION DOSIMETRY, 2008, 128 (01) : 62 - 67
  • [40] Analysis of Low-Frequency Magnetic Coupling in Cables Grounded at Both Ends
    Yaglidere, Ilker
    2017 IV INTERNATIONAL ELECTROMAGNETIC COMPATIBILITY CONFERENCE (EMC TURKIYE), 2017,