Difficult diagnosis of celiac disease: diagnostic accuracy and utility of chromo-zoom endoscopy

被引:11
|
作者
Iovino, Paola [1 ]
Pascariello, Annalisa [2 ]
Russo, Ilaria [1 ]
Galloro, Giuseppe [2 ]
Pellegrini, Lucienne [1 ]
Ciacci, Carolina [1 ]
机构
[1] Univ Salerno, Gastrointestinal Unit, Dept Med & Surg, I-84081 Baronissi, Italy
[2] Univ Naples Federico II, Dept Surg, Endoscopy Unit, Naples, Italy
关键词
GLUTEN-FREE DIET; PATCHY VILLOUS ATROPHY; MAGNIFICATION ENDOSCOPY; SENSITIVE ENTEROPATHY; ORGAN-CULTURE; T-CELLS; GLIADIN; BIOPSY; CHROMOENDOSCOPY; CHALLENGE;
D O I
10.1016/j.gie.2012.09.036
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Chromo-zoom endoscopy has been demonstrated to be valuable in assessing the degree of intestinal villous atrophy in patients with suspected celiac disease. Objective: To evaluate the diagnostic accuracy of chromo-zoom endoscopy in patients with difficult diagnosis because of nonconcordant test results and/or the confounding of a gluten-free diet initiated before an appropriate diagnosis of celiac disease and to compare the findings to a recent reference standard, the in vitro gliadin challenge test. Design: Prospective, case-control study. Setting: Tertiary-care referral hospital. Patients: Patients without celiac disease (negative control group, n = 9), patients with celiac disease (positive control group, n = 41), and patients with difficult diagnosis (n = 27). Intervention: Chromo-endoscopy with indigo carmine and endoscopic zoom-magnification were performed. Duodenal fragments were collected for the in vitro gliadin challenge test. The area under the receiver operating characteristic curve (ROC) was used for statistical analyses on accuracy. Main Outcome Measurements: Diagnostic accuracy of chromo-zoom endoscopy for detection of mucosal abnormalities in patients with difficult diagnosis. Results: Chromo-zoom endoscopy had a high accuracy for celiac disease diagnosis in analyses on negative controls and positive controls (area under roc = 0.99). In the difficult diagnosis group, the accuracy of chromo-zoom endoscopy was lower (area under roc = 0.83), but it increased after exclusion of patients with celiac disease on gluten-free diet (area under roc = 0.88). Limitations: There was a 4% failure rate in the ability to cultivate biopsies. Also, the study was done at an academic medical center. Conclusion: Chromo-zoom endoscopy has high accuracy for cases of difficult diagnosis of celiac disease but only in untreated patients with celiac disease. (Gastrointest Endosc 2013; 77: 233-40.)
引用
收藏
页码:233 / 240
页数:8
相关论文
共 50 条
  • [41] The role of video capsule endoscopy in the diagnosis of celiac disease: a meta-analysis
    Rokkas, Theodore
    Niv, Yaron
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2012, 24 (03) : 303 - 308
  • [42] The diagnostic accuracy of capsule endoscopy in coeliac disease: A blinded pilot study
    Hopper, AD
    Sanders, DS
    McAlindon, ME
    GUT, 2005, 54 : A105 - A105
  • [43] EVALUATION OF THE VILLOUS PATTERN BY CAPSULE ENDOSCOPY: IS IT TIME TO CHANGE THE DIAGNOSTIC APPROACH TO CELIAC DISEASE?
    Spada, C.
    Riccioni, M. E.
    Urgesi, R.
    De Vitis, I.
    Familiari, P.
    Belmonte, M.
    Costamagna, G.
    DIGESTIVE AND LIVER DISEASE, 2008, 40 : S51 - S52
  • [44] Evaluation of the villous pattern by capsule endoscopy: Is it time to change the diagnostic approach to celiac disease?
    Spada, Cristiano
    Riccioni, Maria Elena
    Urgesi, Riccardo
    De Vitis, Italo
    Marchese, Michele
    Familiari, Pietro
    Tringali, Andrea
    Fuso, Paola
    Costamagna, Guido
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB124 - AB124
  • [45] "Experts" Assess the Accuracy of Celiac Disease Diagnosis Performed in the Community Setting
    Niveloni, Sonia I.
    Cabanne, Ana M.
    Vazquez, Horacio
    Sugai, Emilia
    Galich, Miriam
    Smecuol, Edgardo
    Laura Moreno, Maria
    Pinto Sanchez, Maria Ines
    Mazure, Roberto M.
    Hwang, Hui Jer
    Maurino, Eduardo
    Bai, Julio C.
    GASTROENTEROLOGY, 2012, 142 (05) : S183 - S183
  • [46] Utility of upper digestive endoscopy in the diagnosis of Crohn's disease.
    Ferrando, J
    Reig, G
    Ferrando, I
    Llorca, P
    GASTROENTEROLOGY, 1999, 116 (04) : A161 - A161
  • [47] Diagnostic accuracy of a new point-of-care screening assay for celiac disease
    Faiza Benkebil
    Christophe Combescure
    Silvia I Anghel
    Cécile Besson Duvanel
    Michela G Schppi
    World Journal of Gastroenterology, 2013, (31) : 5111 - 5117
  • [48] Diagnostic accuracy of antiendomysial antibodies biopsy test for celiac disease in clinical practice
    Benelli, Elisa
    Zavarise, Giulia
    Pavanello, Paolo M.
    Mario, Federica
    Barberio, Giuseppina
    Gasparella, Marco
    Galuppini, Francesca
    Cataldo, Ivana
    Guido, Maria
    Frigo, Anna C.
    Martelossi, Stefano
    MINERVA GASTROENTEROLOGY, 2024, 70 (03): : 291 - 298
  • [49] Diagnostic accuracy of a new point-of-care screening assay for celiac disease
    Benkebil, Faiza
    Combescure, Christophe
    Anghel, Silvia I.
    Duvanel, Cecile Besson
    Schaeppi, Michela G.
    WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (31) : 5111 - 5117
  • [50] Diagnostic accuracy and utility of three dengue diagnostic tests for the diagnosis of acute dengue infection in Malaysia
    Zhuo Lin Chong
    Shamala Devi Sekaran
    Hui Jen Soe
    Devi Peramalah
    Sanjay Rampal
    Chiu-Wan Ng
    BMC Infectious Diseases, 20