Adverse local tissue reactions in metal-on-polyethylene total hip arthroplasty due to trunnion corrosion THE RISK OF MISDIAGNOSIS

被引:101
|
作者
Whitehouse, M. R. [1 ]
Endo, M. [1 ]
Zachara, S. [2 ]
Nielsen, T. O. [3 ]
Greidanus, N. V. [1 ]
Masri, B. A. [1 ]
Garbuz, D. S. [1 ]
Duncan, C. P. [1 ]
机构
[1] Vancouver Gen Hosp, Vancouver, BC, Canada
[2] Vancouver Gen Hosp, Anat Pathol, Vancouver, BC V5Z 1M9, Canada
[3] Vancouver Gen Hosp, Pathol & Lab Med, Anat Pathol, Vancouver, BC V5Z 1M9, Canada
来源
BONE & JOINT JOURNAL | 2015年 / 97B卷 / 08期
关键词
FRETTING CORROSION; PSEUDOTUMOR; REVISION; COMPONENTS; PRODUCTS; BEARINGS; CREVICE;
D O I
10.1302/0301-620X.97B8.34682
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Adverse reaction to wear and corrosion debris is a cause for concern in total hip arthroplasty (THA). Modular junctions are a potential source of such wear products and are associated with secondary pseudotumour formation. We present a consecutive series of 17 patients treated at our unit for this complication following metal-on-highly cross-linked polyethylene (MoP) THA. We emphasise the risk of misdiagnosis as infection, and present the aggregate laboratory results and pathological findings in this series. The clinical presentation was pain, swelling or instability. Solid, cystic and mixed soft-tissue lesions were noted on imaging and confirmed intra-operatively. Corrosion at the head-neck junction was noted in all cases. No bacteria were isolated on multiple pre- and intra-operative samples yet the mean erythrocyte sedimentation rate was 49 (9 to 100) and C-reactive protein 32 (0.6 to 106) and stromal polymorphonuclear cell counts were noted in nine cases. Adverse soft-tissue reactions can occur in MoP THA owing to corrosion products released from the head-neck junction. The diagnosis should be carefully considered when investigating pain after THA. This may avoid the misdiagnosis of periprosthetic infection with an unidentified organism and mitigate the unnecessary management of these cases with complete single-or two-stage exchange.
引用
收藏
页码:1024 / 1030
页数:7
相关论文
共 50 条
  • [21] Head-stem trunnion dissociation due to corrosion in total hip arthroplasty
    Whitehouse, Michael R.
    ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5 (17)
  • [22] Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty
    Anwander, H.
    Cron, G. O.
    Rakhra, K.
    Beaule, P. E.
    BONE & JOINT RESEARCH, 2016, 5 (03): : 73 - 79
  • [23] In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty
    Komistek, RD
    Dennis, DA
    Ochoa, JA
    Haas, BD
    Hammill, C
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10): : 1836 - 1841
  • [24] Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty
    Hjorth, Mette Holm
    Mechlenburg, Inger
    Soballe, Kjeld
    Roemer, Lone
    Jakobsen, Stig Storgaard
    Stilling, Maiken
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07): : 2279 - 2286
  • [25] MARS MRI Characteristics of Adverse Local Tissue Reactions in Taper Corrosion of Metal-On-Polyethylene THA Differ From Metal-On-Metal THA
    Mahajan, John
    Bonner, Bryant
    Oganesyan, Ruben
    Yeo, Ingwon
    Klemt, Christian
    Kwon, Young-Min
    JOURNAL OF ARTHROPLASTY, 2020, 35 (11): : 3338 - 3342
  • [26] Trunnionosis in Metal-on-Polyethylene Total Hip Arthroplasty With Periprosthetic Infection: A Case Report
    Kobayashi, Fumito
    Oe, Kenichi
    Sogawa, Shohei
    Nakamura, Tomohisa
    Saito, Takanori
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [27] Metal-on-polyethylene is not an option after the fracture of a ceramic component of a total hip arthroplasty
    Fernandez-Valencia, Jenaro A.
    HIP INTERNATIONAL, 2016, 26 (06) : E56 - E56
  • [28] Corrosion at the Head-Neck Taper as a Cause for Adverse Local Tissue Reactions After Total Hip Arthroplasty
    Cooper, H. John
    Della Valle, Craig J.
    Berger, Richard A.
    Tetreault, Matthew
    Paprosky, Wayne G.
    Sporer, Scott M.
    Jacobs, Joshua J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (18): : 1655 - 1661
  • [29] Risk Stratification and Pain Outcomes Following Revision Total Hip Arthroplasty for Adverse Local Tissue Reactions
    Daji, Akshay V.
    Workman, Kalain K.
    Yoo, Charlie J.
    Smith, Clair N.
    Kumar, Deepak
    Weber, Margaret A.
    Snyder, Matthew J.
    Urish, Kenneth L.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (12): : 2406 - 2411
  • [30] Gross trunnion failure in metal on polyethylene total hip arthroplasty—a systematic review of literature
    Tungish Bansal
    Sameer Aggarwal
    Mandeep Singh Dhillon
    Sandeep Patel
    International Orthopaedics, 2020, 44 : 609 - 621