Quality assurance in accelerator mass spectrometry: Results from an international round-robin exercise for 10Be

被引:19
|
作者
Merchel, S. [1 ,2 ]
Bremser, W. [3 ]
Akhmadaliev, S. [1 ]
Arnold, M. [2 ]
Aumaitre, G. [2 ]
Bourles, D. L. [2 ]
Braucher, R. [2 ]
Caffee, M. [4 ]
Christl, M. [5 ]
Fifield, L. K. [6 ]
Finkel, R. C. [2 ,7 ]
Freeman, S. P. H. T. [8 ]
Ruiz-Gomez, A. [9 ]
Kubik, P. W. [5 ]
Martschini, M. [10 ]
Rood, D. H. [7 ,8 ]
Tims, S. G. [6 ]
Wallner, A. [6 ,10 ]
Wilcken, K. M. [8 ]
Xu, S. [8 ]
机构
[1] HZDR, D-01314 Dresden, Germany
[2] Aix Marseille Univ, CNRS, CEREGE ASTER UM34, F-13545 Aix En Provence, France
[3] BAM Fed Inst Mat Res & Testing, D-12489 Berlin, Germany
[4] Purdue Univ, PRIME Lab, W Lafayette, IN 47906 USA
[5] ETH, Lab Ion Beam Phys, CH-8093 Zurich, Switzerland
[6] Australian Natl Univ, Canberra, ACT 0200, Australia
[7] Lawrence Livermore Natl Lab, CAMS, Livermore, CA 94550 USA
[8] SUERC, E Kilbride G75 0QF, Lanark, Scotland
[9] Univ Seville, CNA, Seville 41092, Spain
[10] Univ Vienna, Fac Phys, VERA Lab, A-1090 Vienna, Austria
基金
美国国家科学基金会;
关键词
Accelerator mass spectrometry; Terrestrial cosmogenic nuclides (TCN); Cosmogenic nuclide exposure dating; Calibration; PRODUCTION-RATE CALIBRATION; NUCLIDE PRODUCTION-RATES; COSMOGENIC NUCLIDES; SCALING FACTORS;
D O I
10.1016/j.nimb.2012.07.038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The first international round-robin exercise for the measurement of the long-lived radionuclide Be-10 has been conducted. Ten participating accelerator mass spectrometry CAMS) facilities have each measured three samples at the 10(-12) to 10(-14) Be-10/Be-9 level. All results have been made traceable to the NISI SRM 4325 standard to avoid additional discrepancies that arise when different facilities use different calibration materials. Hence, the data concentrates on pure measurement distinctions. Multivariate statistical investigations have been performed to reveal a bias between facilities, i.e. two distinguished groups could be identified. Maximum discrepancies between two single facilities are in the range of 6-31% depending on the absolute Be-10/Be-9 value. These findings should be considered when comparing Be-10 data produced at one AMS facility with that produced at another facility, which is e.g. often the case for in situ Be-10 dating studies. Round-robin exercises are a very helpful tool as part of an overall quality assurance scheme to improve the accuracy, and not only the precision, of AMS data. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 73
页数:6
相关论文
共 50 条
  • [41] Economically Motivated Adulteration of Lemon Juice: Cavity Ring Down Spectroscopy in Comparison with Isotope Ratio Mass Spectrometry: Round-Robin Study
    Mantha, Madhavi
    Kubachka, Kevin M.
    Urban, John R.
    Dasenbrock, Catherine O.
    Chernyshev, Anatoly
    Mark, William A.
    France, Christine
    Chartrand, Michelle
    Hache, Jonathan
    Decoeur, Sylvain
    Qi, Haiping
    JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (05) : 1544 - 1551
  • [42] Investigation of factors that affect the sensitivity of accelerator mass spectrometry for cosmogenic 10Be and 26Al isotope analysis
    Hunt, A. L.
    Larsen, J.
    Bierman, P. R.
    Petrucci, G. A.
    ANALYTICAL CHEMISTRY, 2008, 80 (05) : 1656 - 1663
  • [43] Results from the first international round robin calibration and measurement of space solar cells
    Matsuda, S
    Flood, D
    Gomez, T
    Yang, YQ
    CONFERENCE RECORD OF THE TWENTY SIXTH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE - 1997, 1997, : 1043 - 1047
  • [44] Co-precipitated silver-metal oxide aggregates for accelerator mass spectrometry of 10Be and 26Al
    Stone, J
    Fifield, K
    Beer, J
    Vonmoos, M
    Obrist, C
    Grajcar, M
    Kubik, P
    Muscheler, R
    Finkel, R
    Caffee, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 223 : 272 - 277
  • [45] Critical view of the results of the 2nd international round-robin test on EIS measurements of organic coatings (vol 180, 107565, 2023)
    Bakalli, Mirdash
    Keil, Patrick
    Strunz, Werner
    Broeker, Thomas
    Herrmann, Rainer
    Vogelsang, Joerg
    PROGRESS IN ORGANIC COATINGS, 2023, 182
  • [46] Development and applications of accelerator mass spectrometry methods for measurement of 14C, 10Be and 26Al in the CENTA laboratory
    Povinec, Pavel P.
    Kontul, Ivan
    Jeskovsky, Miroslav
    Kaizer, Jakub
    Kvasniak, Jakub
    Panik, Jan
    Zeman, Jakub
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (07) : 3497 - 3509
  • [47] Design and performance of an automated chemical extraction bench for the preparation of 10Be and 26Al targets to be analyzed by accelerator mass spectrometry
    Keddadouche, Karim
    Braucher, Regis
    Bourles, Didier L.
    Baroni, Melanie
    Guillou, Valery
    Leanni, Laetitia
    Aumaitre, Georges
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 456 : 230 - 235
  • [48] Results from an international measurement round robin of III-V triple-junction solar cells under air mass zero
    Jenkins, Phillip
    Scheiman, David
    Goodbody, Chris
    Baur, Carsten
    Sharps, Paul
    Imaizumi, Mitsuru
    Yoo, Henry
    Sahlstrom, Ted
    Walters, Robert
    Lorentzen, Justin
    Nocerino, John
    Khan, Osman
    Cravens, Robert
    Valles, Juan
    Toporow, Chantal
    Gomez, Trinidad
    Bazan, Loreto Pazos
    Bailey, Sheila
    CONFERENCE RECORD OF THE 2006 IEEE 4TH WORLD CONFERENCE ON PHOTOVOLTAIC ENERGY CONVERSION, VOLS 1 AND 2, 2006, : 1968 - +
  • [49] Quality assurance in neuropathology: Experiences from the round robin trials on IDH mutation and MGMT promoter methylation testing launched by the Quality Assurance Initiative Pathology (QuIP) in 2018 and 2019
    Riemenschneider, Markus J.
    Fischer, Josephine
    Grassow-Narlik, Maja
    Mawrin, Christian
    von Deimling, Andreas
    Pietsch, Torsten
    Reifenberger, Guido
    Mueller, Wolf C.
    Sommer, Clemens J.
    Dietel, Manfred
    Zoubaa, Saida
    Lorenz, Julia
    Rothhammer-Hampl, Tanja
    CLINICAL NEUROPATHOLOGY, 2020, 39 (05) : 203 - 211
  • [50] DETERMINATION OF LONG-LIVED RADIONUCLIDE (10Be, 41Ca, 129I) CONCENTRATIONS IN NUCLEAR WASTE BY ACCELERATOR MASS SPECTROMETRY
    Nottoli, Emmanuelle
    Bienvenu, Philippe
    Bourles, Didier
    Labet, Alexandre
    Arnold, Maurice
    Bertaux, Maite
    ASME 2013 15TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL REMEDIATION AND RADIOACTIVE WASTE MANAGEMENT, VOL 1: LOW/INTERMEDIATE-LEVEL RADIOACTIVE WASTE MANAGEMENT; SPENT FUEL, FISSILE MATERIAL, TRANSURANIC AND HIGH-LEVEL RADIOACTIVE WASTE MANAGEMENT, 2013,