Extraction induced by emulsion breaking for simultaneous determination of Co, Fe and Ni in petroleum asphalt cement by high-resolution continuum source atomic absorption spectrometry

被引:17
|
作者
Adolfo, Franciele Rovasi [1 ]
do Nascimento, Paulo Cicero [1 ]
Bohrer, Denise [1 ]
Viana, Carine [1 ]
de Carvalho, Leandro Machado [1 ]
Coutinho Cravo, Margareth C. [2 ]
Nascimento, Luis [2 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, Santa Maria, RS, Brazil
[2] Petrobras SA, Ctr Pesquisa & Desenvolvimento Leopoldo Amer Migu, Rio De Janeiro, RJ, Brazil
关键词
Simultaneous determination; High-resolution continuum source GF AAS; Extraction induced by emulsion breaking; Asphalt cement; Metals; OPTICAL-EMISSION SPECTROMETRY; PLASMA-MASS SPECTROMETRY; CRUDE-OIL; MICROEMULSION BREAKING; METALS DETERMINATION; LUBRICATING OILS; VANADIUM; NICKEL; CU; MN;
D O I
10.1016/j.fuel.2020.118098
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper reports, for the first time, the simultaneous determination of Co, Fe and Ni in petroleum asphalt cement by high-resolution continuum source atomic absorption spectrometry after extraction induced by the emulsion breaking method. The variables that could influence the sample preparation were evaluated, like sample dilution with toluene and mineral oil, extraction time, HNO3 and Triton X-100 concentration in the aqueous extractant solution. M optimized conditions, 0.08 g of the sample was dissolved with 1.5 mL of toluene and 3.5 mL of mineral oil and vigorous mixed with the extractant solution containing 40% (v/v) of HNO3 and 40% (v/v) of Triton-X-100. The emulsions were broken by heating just after their formation and the aqueous extracts were collected for analysis. Simultaneous determination was carried out at the secondary lines of Co (352.685 nm), Fe (352.604 nm) and Ni (352.454 nm). For this purpose, the best pyrolysis and atomization temperatures were 700 and 2400 degrees C, respectively. Calibration was performed with standard aqueous solutions and no matrix effects were observed. The limit of detection was 0.003 mg L-1 for Co, 0.018 mg L-1 for Fe and 0.027 mg L-1 for Ni. Method accuracy was confirmed by comparing the results obtained by the proposed extraction method with those obtained after samples acid digestion. Recoveries ranged from 100 to 107%, 103 to 109% and 95.5 to 98.9% were obtained for Co, Fe and Ni, respectively.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A new method based on extraction induced by emulsion breaking for determination of Co and Ni in chocolate bars by graphite furnace atomic absorption spectrometry
    Adolfo, Franciele Rovasi
    Lucena, Nicoly Balczareki
    Valle, Lucas Trombe Do
    Carvalho, Leandro Machado De
    Kunz, Simone Noremberg
    FOOD CHEMISTRY, 2024, 448
  • [32] Determination of Cd, Ni and V in Spices by Solid Sampling High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Virgilio, Alex
    Rego, Jardes F.
    Barros, Ariane I.
    Gomes Neto, Jose A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (10) : 1988 - 1993
  • [33] CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY WITH HIGH-RESOLUTION AND WAVELENGTH MODULATION
    ZANDER, AT
    OHAVER, TC
    KELIHER, PN
    ANALYTICAL CHEMISTRY, 1976, 48 (08) : 1166 - 1175
  • [34] Feasibility of filter atomization in high-resolution continuum source atomic absorption spectrometry
    Heitmann, Uwe
    Becker-Ross, Helmut
    Katskov, Dmitri
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (03) : 351 - 360
  • [35] Quo vadis high-resolution continuum source atomic/molecular absorption spectrometry?
    Resano, M.
    Garcia-Ruiz, E.
    Aramendia, M.
    Belarra, M. A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (01) : 59 - 80
  • [36] High-resolution continuum source atomic absorption spectrometry: a review of current applications
    V. V. Eskina
    V. B. Baranovskaya
    Yu. A. Karpov
    D. G. Filatova
    Russian Chemical Bulletin, 2020, 69 : 1 - 16
  • [37] High-resolution continuum source atomic absorption spectrometry: a review of current applications
    Eskina, V. V.
    Baranovskaya, V. B.
    Karpov, Yu. A.
    Filatova, D. G.
    RUSSIAN CHEMICAL BULLETIN, 2020, 69 (01) : 1 - 16
  • [38] Simultaneous determination of V, Ni and Fe in fuel fly ash using solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry
    Cardenas Valdivia, A.
    Vereda Alonso, E.
    Lopez Guerrero, M. M.
    Gonzalez-Rodriguez, J.
    Cano Pavon, J. M.
    Garcia de Torres, A.
    TALANTA, 2018, 179 : 1 - 8
  • [39] Direct determination of P in biodiesel by high-resolution continuum source graphite furnace atomic absorption spectrometry
    de Campos, Reinaldo Calixto
    Correia, Carolina Lyrio T.
    Vieira, Flavia
    Saint'Pierre, Tatiana D.
    Oliveira, Ana Cristina
    Goncalves, Rodrigo
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) : 352 - 355
  • [40] Determination of Cu and Mn in Seawater by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Burylin, Mikhail Yu
    Kopeyko, Elena S.
    Bauer, Viktoriya A.
    ANALYTICAL LETTERS, 2022, 55 (10) : 1663 - 1671