Extraction induced by emulsion breaking for simultaneous determination of Co, Fe and Ni in petroleum asphalt cement by high-resolution continuum source atomic absorption spectrometry

被引:17
|
作者
Adolfo, Franciele Rovasi [1 ]
do Nascimento, Paulo Cicero [1 ]
Bohrer, Denise [1 ]
Viana, Carine [1 ]
de Carvalho, Leandro Machado [1 ]
Coutinho Cravo, Margareth C. [2 ]
Nascimento, Luis [2 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, Santa Maria, RS, Brazil
[2] Petrobras SA, Ctr Pesquisa & Desenvolvimento Leopoldo Amer Migu, Rio De Janeiro, RJ, Brazil
关键词
Simultaneous determination; High-resolution continuum source GF AAS; Extraction induced by emulsion breaking; Asphalt cement; Metals; OPTICAL-EMISSION SPECTROMETRY; PLASMA-MASS SPECTROMETRY; CRUDE-OIL; MICROEMULSION BREAKING; METALS DETERMINATION; LUBRICATING OILS; VANADIUM; NICKEL; CU; MN;
D O I
10.1016/j.fuel.2020.118098
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper reports, for the first time, the simultaneous determination of Co, Fe and Ni in petroleum asphalt cement by high-resolution continuum source atomic absorption spectrometry after extraction induced by the emulsion breaking method. The variables that could influence the sample preparation were evaluated, like sample dilution with toluene and mineral oil, extraction time, HNO3 and Triton X-100 concentration in the aqueous extractant solution. M optimized conditions, 0.08 g of the sample was dissolved with 1.5 mL of toluene and 3.5 mL of mineral oil and vigorous mixed with the extractant solution containing 40% (v/v) of HNO3 and 40% (v/v) of Triton-X-100. The emulsions were broken by heating just after their formation and the aqueous extracts were collected for analysis. Simultaneous determination was carried out at the secondary lines of Co (352.685 nm), Fe (352.604 nm) and Ni (352.454 nm). For this purpose, the best pyrolysis and atomization temperatures were 700 and 2400 degrees C, respectively. Calibration was performed with standard aqueous solutions and no matrix effects were observed. The limit of detection was 0.003 mg L-1 for Co, 0.018 mg L-1 for Fe and 0.027 mg L-1 for Ni. Method accuracy was confirmed by comparing the results obtained by the proposed extraction method with those obtained after samples acid digestion. Recoveries ranged from 100 to 107%, 103 to 109% and 95.5 to 98.9% were obtained for Co, Fe and Ni, respectively.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Simultaneous determination of Ba, Co, Fe, and Ni in nuts by high-resolution continuum source atomic absorption spectrometry after extraction induced by solid-oil-water emulsion breaking
    Adolfo, Franciele Rovasi
    do Nascimento, Paulo Cicero
    Brudi, Leticia
    Bohrer, Denise
    de Carvalho, Leandro Machado
    FOOD CHEMISTRY, 2021, 345
  • [2] Simultaneous determination of Ba, Co, Fe, and Ni in nuts by high-resolution continuum source atomic absorption spectrometry after extraction induced by solid-oil-water emulsion breaking
    Rovasi Adolfo, Franciele
    Cícero do Nascimento, Paulo
    Brudi, Letícia
    Bohrer, Denise
    Machado de Carvalho, Leandro
    Food Chemistry, 2021, 345
  • [3] Extraction method based on emulsion breaking for the determination of Cu, Fe and Pb in Brazilian automotive gasoline samples by high-resolution continuum source flame atomic absorption spectrometry
    Leite, Clarice C.
    de Jesus, Alexandre
    Kolling, Leandro
    Ferrao, Marco F.
    Samios, Dimitrios
    Silva, Marcia M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 142 : 62 - 67
  • [4] Extraction Induced by Emulsion Breaking for Ca, Fe, Mg, and Zn Determination in Edible Oils Using High-Resolution Continuous Source Flame Atomic Absorption Spectrometry
    Uillian Mozart Ferreira da Mata Cerqueira
    Gisseli Souza Valasques
    Cheilane Tavares de Souza
    Sulene Alves Araújo
    Marcos Almeida Bezerra
    Cleber Galvão Novaes
    Food Analytical Methods, 2022, 15 : 1098 - 1106
  • [5] Extraction Induced by Emulsion Breaking for Ca, Fe, Mg, and Zn Determination in Edible Oils Using High-Resolution Continuous Source Flame Atomic Absorption Spectrometry
    Ferreira da Mata Cerqueira, Uillian Mozart
    Valasques, Gisseli Souza
    de Souza, Cheilane Tavares
    Araujo, Sulene Alves
    Bezerra, Marcos Almeida
    Novaes, Cleber Galvao
    FOOD ANALYTICAL METHODS, 2022, 15 (04) : 1098 - 1106
  • [7] Simultaneous determination of Co, Fe, Ni and Pb in carbon nanotubes by means of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
    Resano, Martin
    Bolea-Fernandez, Eduardo
    Mozas, Engracia
    Florez, Maria R.
    Grinberg, Patricia
    Sturgeon, Ralph E.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (05) : 657 - 665
  • [8] Determination of Cr and Ni in Seawater by High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    M. Yu. Burylin
    E. S. Kopeyko
    E. S. Kostyuchenko
    Journal of Analytical Chemistry, 2024, 79 : 310 - 317
  • [9] Determination of Cr and Ni in Seawater by High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    Burylin, M. Yu.
    Kopeyko, E. S.
    Kostyuchenko, E. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (03) : 310 - 317
  • [10] Extraction induced by emulsion breaking to assay Cr, Cu and Mn in asphalt samples by high-resolution continuum source atomic absorption spectrometry and its comparison with other sample preparation methods
    Adolfo, Franciele Rovasi
    do Nascimento, Paulo Cicero
    Brudi, Leticia
    Bohrer, Denise
    de Carvalho, Leandro Machado
    Cravo, Margareth C. Coutinho
    Nascimento, Luis
    TALANTA, 2021, 234 (234)