Bioimpedance for the spot measurement of tissue density

被引:3
|
作者
Dylke, E. S. [1 ]
Ward, L. C.
Stannard, C. [1 ]
Leigh, A. [1 ]
Kilbreath, S. L. [1 ]
机构
[1] Univ Sydney, Fac Hlth Sci, Sydney, NSW 2006, Australia
来源
XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT) | 2013年 / 434卷
关键词
ARM LYMPHEDEMA;
D O I
10.1088/1742-6596/434/1/012054
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Long-standing lymphoedema is characterised by tissues changes which are currently not detectable using bioimpedance spectroscopy. It has been suggested that a combination of bipolar and tetrapolar measurements may be used to detect these tissues changes for a single site in the transverse direction. This was technique was trialled in a group of control participants with no history of lymphoedema or recent upper limb trauma. Repeated spot measurements were done without removal of electrodes to determine biological variability as well as with removal of electrodes to determine technical reproducibility. The inter-limb spot ratio of the controls was then compared to that of a number of women previously diagnosed with secondary lymphoedema in the forearm. Biological variability was not found to greatly influence repeated measures but only moderate technical reliability was found despite excellent co-efficient of variation for the majority of the measurements. A difference was seen between those with more severe swelling and the controls. This novel technique shows promise in detecting tissue changes associated with long-standing lymphoedema.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Optimization of Multisine Excitation for a Bioimpedance Measurement Device
    Ojarand, J.
    Annus, P.
    Min, M.
    Gorev, M.
    Ellervee, P.
    2014 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) PROCEEDINGS, 2014, : 829 - 832
  • [32] Low-Energy Chirps for Bioimpedance Measurement
    Paavle, Toivo
    Min, Mart
    Trebbels, Dennis
    2011 34TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2011, : 398 - 402
  • [33] Electrical bioimpedance for noninvasive measurement of cardiac output
    Weil, MH
    CRITICAL CARE MEDICINE, 1997, 25 (09) : 1455 - 1455
  • [34] Design and Uncertainty Analysis of a Bioimpedance Measurement Channel
    Schuck, Adalberto, Jr.
    Balbinot, Alexandre
    Porto, Rodrigo Wolff
    2013 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2013, : 1585 - 1589
  • [35] Noninvasive measurement of the electrical bioimpedance of breast tumors
    Ohmine, Y
    Morimoto, T
    Kinouchi, Y
    Iritani, T
    Takeuchi, M
    Monden, Y
    ANTICANCER RESEARCH, 2000, 20 (3B) : 1941 - 1946
  • [36] State space modeling of bioimpedance for haematocrit measurement
    Akulov, S. A.
    Fedotov, A. A.
    Akulova, A. S.
    Reshetnikova, M. A.
    16TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2017, 61 : 95 - 98
  • [37] A Robust Electrode Configuration for Bioimpedance Measurement of Respiration
    Wang, Hong-bin
    Yen, Chen-wen
    Liang, Jing-tao
    Wang, Qian
    Liu, Guan-zheng
    Song, Rong
    JOURNAL OF HEALTHCARE ENGINEERING, 2014, 5 (03) : 313 - 327
  • [38] Electrical bioimpedance measurement: methods and equivalent circuits
    Gordon, R
    Parve, T
    BEC 2002: PROCEEDINGS OF THE 8TH BIENNIAL BALTIC ELECTRONIC CONFERENCE, 2002, : 363 - 366
  • [39] Textile electrodes for the measurement of bioimpedance spectroscopy signals
    Zimmermann, Nadine
    Gries, Thomas
    Medrano, Guillermo
    Leonrardt, Steffen
    WMSCI 2007: 11TH WORLD MULTI-CONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL IV, PROCEEDINGS, 2007, : 177 - +
  • [40] Transcranial bioimpedance measurement in horses: a pilot study
    Gregson, Rachael A.
    Shaw, Martin
    Piper, Ian
    Clutton, R. Eddie
    VETERINARY ANAESTHESIA AND ANALGESIA, 2019, 46 (05) : 620 - 626