Bioimpedance for the spot measurement of tissue density

被引:3
|
作者
Dylke, E. S. [1 ]
Ward, L. C.
Stannard, C. [1 ]
Leigh, A. [1 ]
Kilbreath, S. L. [1 ]
机构
[1] Univ Sydney, Fac Hlth Sci, Sydney, NSW 2006, Australia
来源
XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT) | 2013年 / 434卷
关键词
ARM LYMPHEDEMA;
D O I
10.1088/1742-6596/434/1/012054
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Long-standing lymphoedema is characterised by tissues changes which are currently not detectable using bioimpedance spectroscopy. It has been suggested that a combination of bipolar and tetrapolar measurements may be used to detect these tissues changes for a single site in the transverse direction. This was technique was trialled in a group of control participants with no history of lymphoedema or recent upper limb trauma. Repeated spot measurements were done without removal of electrodes to determine biological variability as well as with removal of electrodes to determine technical reproducibility. The inter-limb spot ratio of the controls was then compared to that of a number of women previously diagnosed with secondary lymphoedema in the forearm. Biological variability was not found to greatly influence repeated measures but only moderate technical reliability was found despite excellent co-efficient of variation for the majority of the measurements. A difference was seen between those with more severe swelling and the controls. This novel technique shows promise in detecting tissue changes associated with long-standing lymphoedema.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Bioimpedance measurement of extracellular water - Reply
    Matthie, J
    Zarowitz, B
    De Lorenzo, A
    Katzarski, K
    JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (02) : 773 - 774
  • [22] High Precision System for Bioimpedance Measurement
    Le Manh Hai
    Nguyen Thi Thuong
    Vu Ngoc Tuan
    II LATIN AMERICAN CONFERENCE ON BIOIMPEDANCE, 2016, 54 : 1 - 4
  • [23] MEASUREMENT OF ELECTRICAL BIOIMPEDANCE AND ITS APPLICATIONS
    YAMAMOTO, Y
    YAMAMOTO, T
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1987, 12 (3-4) : 171 - 183
  • [24] Bioimpedance measurement system for household healthcare
    State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instruments and Mechanology, Tsinghua University, Beijing 100084, China
    Qinghua Daxue Xuebao, 2007, 8 (1330-1333):
  • [25] A Multiscale Model for Bioimpedance Dispersion of Liver Tissue
    Huang, W. H.
    Chui, C. K.
    Teoh, S. H.
    Chang, S. K. Y.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (06) : 1593 - 1597
  • [26] A sampling multichannel bioimpedance analyzer for tissue monitoring
    Min, M
    Land, R
    Märtens, O
    Parve, T
    Ronk, A
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 902 - 905
  • [27] Four electrode embedded bioimpedance measurement system
    Margo, Cedric
    Katrib, Juliano
    Nadi, Mustapha
    Rouane, Amar
    2013 IEEE FAIBLE TENSION FAIBLE CONSOMMATION (FTFC), 2013,
  • [28] Influence of various factors on the measurement of multifrequency bioimpedance
    Gualdi-Russo, E
    Toselli, S
    HOMO-JOURNAL OF COMPARATIVE HUMAN BIOLOGY, 2002, 53 (01) : 1 - 16
  • [29] Detection and Classification of Measurement Errors in Bioimpedance Spectroscopy
    Ayllnon, David
    Gil-Pita, Roberto
    Seoane, Fernando
    PLOS ONE, 2016, 11 (06):
  • [30] An Improved Measurement System for Electrical Bioimpedance Spectroscopy
    Zhang, Shuaifu
    Xu, Yanbin
    Hu, Qingwei
    Chen, Fan
    Cui, Ziqiang
    Lv, Qi
    Fan, Haojun
    Dong, Feng
    2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024, 2024,