A Preliminary Comparative Study of Young's Modulus Versus Shear Modulus in the Diagnosis of Breast Cancer

被引:10
|
作者
Wu, Huaiyu [1 ]
Liang, Weiyu [1 ]
Jiao, Yang [1 ]
Song, Hong [1 ]
Peng, Quanzhou [2 ]
Luo, Hui [1 ]
Zhang, Yuanji [1 ]
Xu, Jinfeng [1 ,2 ]
Dong, Fajin [1 ,2 ]
机构
[1] Jinan Univ, Shenzhen Peoples Hosp, Shenzhen Med Ultrasound Engn Ctr, Dept Ultrasound,Clin Med Coll 2, 1017 Dongmen North Rd, Shenzhen 518020, Peoples R China
[2] Jinan Univ, Clin Med Coll 2, Shenzhen Peoples Hosp, Dept Pathol, Shenzhen, Peoples R China
基金
中国国家自然科学基金;
关键词
elastic imaging technique; shear modulus; Young's modulus; breast cancer; differential diagnosis; WAVE ELASTOGRAPHY; SCREENING US; ULTRASOUND; WOMEN; MAMMOGRAPHY; MASSES;
D O I
10.1097/RUQ.0000000000000434
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to compare the diagnostic value of Young's modulus (E) and shear modulus (G) in the differential diagnosis of benign and malignant breast masses using sound touch elastography (STE) and to explore the relationship between G and E in breast lesions. Methods A total of 96 consecutive women with 110 pathologically confirmed breast masses were included. All masses were detected by conventional and STE ultrasound. E-mean, E-max, E-min, E-SD, G(mean), G(max), G(min), and G(SD) were determined and evaluated for evidence of significant differences between benign and malignant breast masses. Receiver operator characteristics were used to compare the diagnostic efficacy of E and G and to determine the G cutoff value that would aid in the differential diagnosis of breast cancer. ResultsE(mean), E-max, E-SD, G(mean), G(max), and G(SD) in cases of malignant breast masses were significantly higher than those in cases of benign masses (P < 0.05). There was no significant difference between E-min and G(min) (P = 0.565). In applying the E-mean, E-max, E-SD, G(mean), G(max), and G(SD) to the receiver operator characteristics: (1) the area under the curve (AUC) of G(mean) and G(max) is greater than the AUC of E-mean and E-max, and the AUC of E-SD is equal to the AUC of G(SD). (2) The sensitivity and specificity were highest when the G(mean) was 10.14 kPa. They were 84.1% and 80.3% respectively. (3) The sensitivity and specificity were highest when the G(max) was 52.20 kPa. They were 88.6% and 87.9% respectively. Conclusions These preliminary results of STE evaluation of breast masses suggest that the diagnostic value of G is greater than E. Furthermore, STE is a valuable tool in the differential diagnosis of breast lesions.
引用
收藏
页码:88 / 92
页数:5
相关论文
共 50 条
  • [41] Comparative Study on Complex Modulus and Dynamic Modulus of High-Modulus Asphalt Mixture
    Guo, Licheng
    Xu, Qinsheng
    Zeng, Guodong
    Wu, Wenjuan
    Zhou, Min
    Yan, Xiangpeng
    Zhang, Xiaomeng
    Wei, Jincheng
    COATINGS, 2021, 11 (12)
  • [42] Determination of the young's modulus and shear modulus of solid wood by the symmetric and asymmetric four-point bending tests
    Yoshihara H.
    Yoshinobu M.
    Maruta M.
    Zairyo/Journal of the Society of Materials Science, Japan, 2020, 69 (06) : 429 - 433
  • [43] Orientation dependencies of Young's modulus E and shear modulus G of tempered Cu-strips for spring elements
    Kuhn, HA
    Nothhelfer-Richter, R
    Futterknecht, G
    METALL, 2000, 54 (10): : 575 - 580
  • [44] Comparative Study on Laboratory and Field Test of Maximum Dynamic Shear Modulus
    Sun, Jing
    Yuan, Xiao-ming
    Gong, Mao-sheng
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 478 - +
  • [45] Measurement of Young's Modulus and Shear Modulus of some Structures Welded Using Flux Cored Wire by Vibration Tests
    Bereteu, Liviu
    Voda, Mircea
    Draganescu, Gheorghe
    ADVANCED MATERIALS AND STRUCTURES V, 2014, 216 : 151 - 156
  • [46] Influence of the sintering temperature on Young's modulus and the shear modulus of tricalcium phosphate - fluorapatite composites evaluated by ultrasound techniques
    Bouslama, Nadhem
    Chevalier, Yvon
    Bouaziz, Jamel
    Ben Ayed, Foued
    MATERIALS CHEMISTRY AND PHYSICS, 2013, 141 (01) : 289 - 297
  • [47] In Vivo Quantification of the Nonlinear Shear Modulus in Breast Lesions: Feasibility Study
    Bernal, Miguel
    Chamming's, Foucauld
    Couade, Mathieu
    Bercoff, Jeremy
    Tanter, Mickael
    Gennisson, Jean-Luc
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (01) : 101 - 109
  • [48] Comparative Analysis of Estimated Young's Modulus of Rubberized Mortar and Concrete
    Belabdelouahab, Farid
    Trouzine, Habib
    Hellal, Hadjira
    Rahali, Bachir
    Kaci, Soufiane Ould
    Medine, Malika
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2018, 16 (2A) : 243 - 253
  • [49] Comparative Analysis of Estimated Young’s Modulus of Rubberized Mortar and Concrete
    Farid Belabdelouahab
    Habib Trouzine
    Hadjira Hellal
    Bachir Rahali
    Soufiane Ould Kaci
    Malika Medine
    International Journal of Civil Engineering, 2018, 16 : 243 - 253
  • [50] Probing the Young's modulus and Poisson's ratio in graphene/metal interfaces and graphite: A comparative study
    Politano, Antonio
    Chiarello, Gennaro
    NANO RESEARCH, 2015, 8 (06) : 1847 - 1856