A comparison of distal femoral locking plates for distal femur fractures: Long working length versus short working length

被引:0
|
作者
Shah, Faaiz Ali [1 ]
Ali, Mian Amjad [1 ]
Hassan, Waqar [1 ]
Bukhari, Syed Imran [1 ]
Bukhari, Syed Imran [1 ]
机构
[1] Lady Reading Hosp, Dept Orthopaed, Peshawar, Pakistan
关键词
Bone plate; Bony callus; Femoral fractures; Fracture healings; Internal fixation device; Titanium; STIFFNESS; FAILURE;
D O I
10.47391/JPMA.3577
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare long working length distal femoral locking plates with short working length for treating extra -articular distal femur fractures in terms of union and implant failure.Method: The randomised controlled trial was conducted at the Lady Reading Hospital, Peshawar, Pakistan, from April 28, 2018, to March 10, 2021, and comprised all adult patients of either gender with extra-articular distal femur fractures who were randomised into two groups. Group A was exposed to long working length, while group B had short working length. Patients in both the groups were followed up regularly for one year for the assessment of fracture union and implant failure. Data was analysed using SPSS 22.Results: In the group of the 61 patients, 30(49.2%) were in group A; 24(80%) males and 6(20%) females with overall mean age of 37.9 +/- 9.6 years. The remaining 31(50.8%) were in group B; 26(83.8%) males and 5(16.1%) females with overall mean age of 37.2 +/- 1 years. The mean working length in group A was 75 +/- 5mm and in group B it was 35 +/- 9mm. In group A 28(93.3%) fractures healed, while in group B 19(61.2%) fractures achieved union (p=0.01). Non-union was noted in 2(6.6%) patients in group A and 7(22.5%) in group B (p=0.08). Plate breakage was noted in 3(9.6%) patients and screw breakage in 2(6.4%) patients in group B and none in group A (p=0.0001).Conclusion: Long working length titanium locking plates were found to be better than short working length in achieving fracture union and avoiding implant failure.Clinical Trial Number: ACTRN12619001023145 http://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=377657&isReview=true
引用
收藏
页码:2154 / 2159
页数:6
相关论文
共 50 条
  • [31] Biomechanical Comparison of Polyaxial-Type Locking Plates and a Fixed-Angle Locking Plate for Internal Fixation of Distal Femur Fractures
    Otto, Randall J.
    Moed, Berton R.
    Bledsoe, J. Gary
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (09) : 645 - 652
  • [32] Radiographic Healing of Far Cortical Locking Constructs in Distal Femur Fractures: A Comparative Study With Standard Locking Plates
    Plumarom, Yanin
    Wilkinson, Brandon G.
    Marsh, J. Lawrence
    Willey, Michael C.
    An, Qiang
    Gao, Yubo
    Karam, Matthew D.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (06) : 277 - 283
  • [33] The Management of Aseptic Non-unions of Distal Femur Fractures with Anatomical Lateral Locking Plates
    Mukhopadhaya, John
    Ranjan, Rajeev
    Sinha, Amit Kumar
    Bhadani, Janki Sharan
    [J]. STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2022, 17 (03) : 137 - 143
  • [34] Distal Locking of Proximal Femoral Nails in Intertrochanteric Fractures: A Comparison of Taloned and Static Locking Systems
    Karagoz, B.
    Keceli, O.
    Agir, I
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2024, 27 (05) : 620 - 627
  • [35] A comparison of complication rates between locking and non-locking plates in distal fibular fractures
    Moriarity, A.
    Ellanti, P.
    Mohan, K.
    Fhoghlu, C. Ni
    Fenelon, C.
    McKenna, J.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (04) : 503 - 506
  • [36] Mono- versus polyaxial locking plates in distal femur fractures - a biomechanical comparison of the Non-Contact-Bridging- (NCB) and the PERILOC-plate
    El-Zayat, Bilal Farouk
    Efe, Turgay
    Ruchholtz, Steffen
    Khatib, Salim
    Timmesfeld, Nina
    Krueger, Antonio
    Zettl, Ralph
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [37] Mono- versus polyaxial locking plates in distal femur fractures – a biomechanical comparison of the Non-Contact-Bridging- (NCB) and the PERILOC-plate
    Bilal Farouk El-Zayat
    Turgay Efe
    Steffen Ruchholtz
    Salim Khatib
    Nina Timmesfeld
    Antonio Krüger
    Ralph Zettl
    [J]. BMC Musculoskeletal Disorders, 15
  • [38] Fixation of periprosthetic or osteoporotic distal femoral fractures with locking plates: a pilot randomised controlled trial
    Kanakaris, Nikolaos K.
    Obakponovwe, Oghofori
    Krkovic, Matija
    Costa, Matt L.
    Shaw, David
    Mohanty, Khitish R.
    West, Robert M.
    Giannoudis, Peter V.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2019, 43 (05) : 1193 - 1204
  • [39] Letter to the editor on “Functional outcome of open distal femoral fractures managed with lateral locking plates”
    Vipul Vijay
    [J]. International Orthopaedics, 2020, 44 : 809 - 810
  • [40] Letter to the editor on "Functional outcome of open distal femoral fractures managed with lateral locking plates"
    Vijay, Vipul
    [J]. INTERNATIONAL ORTHOPAEDICS, 2020, 44 (04) : 809 - 810