摘要
Objectives: The vertical location of the implant-abutment connection influences the periimplant bone morphology. It is unknown, however, whether different microgap configurations cause different bone reactions. Therefore, in this study the bone morphologies of two different implant systems were compared. Material and methods: Three months after tooth extraction in eight mongrel dogs, two grit-blasted screw implants with internal Morse taper connection (ANK group) were placed on one side whereas the contralateral side received two oxidized screw implants with external hex (TIU group). One implant on each side was placed level with the bone (equicrestal), the second implant was inserted 1.5mm below bone level (subcrestal). After 3 months the implants were uncovered. Three months after stage two surgery, histometrical evaluations were performed in order to assess the periimplant bone levels (PBL), the first bone-to-implant contact points (BICP), the width (HBD) and the steepness (SLO) of the bone defect. Results: All implants osseointegrated clinically and histologically. Bone overgrowth of the microgap was seen in ANK implants only. No significant differences between ANK and TIU could be detected in neither vertical position for PBL and BICP. However, a tendency in favor of ANK was visible when the implants were placed subcrestally. In the parameters HBD (ANK equicrestal -0.23mm; TIU equicrestal -0.51mm; ANK subcrestal +0.19mm; TIU subcrestal -0.57mm) and SLO (ANK equicrestal 35.36 degrees; TIU equicrestal 63.22 degrees; ANK subcrestal 20.40 degrees; TIU subcrestal 44.43 degrees) more pronounced and significant differences were noted. Conclusions: Within the limits of this study, it is concluded that different microgap designs cause different shapes and sizes of the periimplant ('dish-shaped') bone defect in submerged implants both in equicrestal and subcrestal positions.
引用
收藏
页码:1141 / 1147
页数:7
相关论文
共 50 条
  • [31] Bone Response to Osteopontin-Functionalized Carboxyethylphosphonic Acid-Modified Implants. Experimental Study in a Minipig Model
    Aragoneses, Javier
    Lopez-Valverde, Nansi
    Lopez-Valverde, Antonio
    Rodriguez, Cinthia
    De Sousa, Bruno Macedo
    Aragoneses, Juan Manuel
    FRONTIERS IN MATERIALS, 2022, 9
  • [32] Influence of homeopathic treatment with comfrey on bone density around titanium implants. A digital subtraction radiography study in rats
    Sakakura, Celso Eduardo
    Neto, Rubens Spin
    Bellucci, Marina
    Wenzel, Ann
    Scaf, Gulnara
    Marcantonio, Elcio, Jr.
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (06) : 624 - 628
  • [33] Spontaneous progression of peri-implantitis at different types of implants. An experimental study in dogs. I: clinical and radiographic observations
    Albouy, Jean-Pierre
    Abrahamsson, Ingemar
    Persson, Leif G.
    Berglundh, Tord
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (10) : 997 - 1002
  • [34] Bone healing pattern in surgically created circumferential defects around submerged implants: an experimental study in dog
    Rossi, Fabio
    Botticelli, Daniele
    Pantani, Fabio
    Pereira, Flavia Priscila
    Salata, Luiz Antonio
    Lang, Niklaus P.
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (01) : 41 - 48
  • [35] Deproteinized bovine bone mineral particles and osseointegration of implants without primary bone contact: an experimental study in dogs
    Sivolella, Stefano
    Bressan, Eriberto
    Salata, Luiz A.
    Quinones, Maria E.
    Lang, Niklaus P.
    Botticelli, Daniele
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (03) : 296 - 303
  • [36] Stability of crestal bone level at platform-switched non-submerged titanium implants: a histomorphometrical study in dogs
    Becker, Juergen
    Ferrari, Daniel
    Mihatovic, Ilja
    Sahm, Narja
    Schaer, Alex
    Schwarz, Frank
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2009, 36 (06) : 532 - 539
  • [37] Bone reactions around dental implants subjected to progressive static load: an experimental study in dogs
    Podaropoulos, Leonidas
    Veis, Alexander A.
    Trisi, Paolo
    Papadimitriou, Serafim
    Alexandridis, Constantinos
    Kalyvas, Demos
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (07) : 910 - 917
  • [38] Vertical ridge augmentation with guided bone regeneration in association with dental implants: an experimental study in dogs
    Simion, Massimo
    Dahlin, Christer
    Rocchietta, Isabella
    Stavropoulos, Andreas
    Sanchez, Raquel
    Karring, Thorkild
    CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (01) : 86 - 94
  • [39] Bone tissue formation adjacent to implants placed in fresh extraction sockets: an experimental study in dogs
    Botticelli, Daniele
    Persson, Leif G.
    Lindhe, Jan
    Berglundh, Tord
    CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (04) : 351 - 358
  • [40] Bone Ceramic® at Implants Installed Immediately into Extraction Sockets in the Molar Region: An Experimental Study in Dogs
    Pereira, Flavia Priscila
    Hochuli-Vieira, Eduardo
    Mate Sanchez de Val, Jose E.
    De Santis, Enzo
    Salata, Luiz Antonio
    Botticelli, Daniele
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (02) : 360 - 368