Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs

被引:112
|
作者
Weng, Dietmar [1 ]
Hitomi Nagata, Maria Jose [2 ]
Bell, Matthias [1 ]
Bosco, Alvaro Francisco [2 ]
Nascimento de Melo, Luiz Gustavo [2 ]
Richter, Ernst-Juergen [1 ]
机构
[1] Univ Wurzburg, Sch Dent Med, Dept Prosthodont, Wurzburg, Germany
[2] Sao Paulo State Univ Julio de Mesquita Filho UNES, Dept Surg & Integrated Clin, Dent Sch Araccatuba, Div Periodont, Sao Paulo, Brazil
关键词
bone morphology; equicrestal placement; histometric study; microgap; subcrestal placement;
D O I
10.1111/j.1600-0501.2008.01564.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The vertical location of the implant-abutment connection influences the periimplant bone morphology. It is unknown, however, whether different microgap configurations cause different bone reactions. Therefore, in this study the bone morphologies of two different implant systems were compared. Material and methods: Three months after tooth extraction in eight mongrel dogs, two grit-blasted screw implants with internal Morse taper connection (ANK group) were placed on one side whereas the contralateral side received two oxidized screw implants with external hex (TIU group). One implant on each side was placed level with the bone (equicrestal), the second implant was inserted 1.5mm below bone level (subcrestal). After 3 months the implants were uncovered. Three months after stage two surgery, histometrical evaluations were performed in order to assess the periimplant bone levels (PBL), the first bone-to-implant contact points (BICP), the width (HBD) and the steepness (SLO) of the bone defect. Results: All implants osseointegrated clinically and histologically. Bone overgrowth of the microgap was seen in ANK implants only. No significant differences between ANK and TIU could be detected in neither vertical position for PBL and BICP. However, a tendency in favor of ANK was visible when the implants were placed subcrestally. In the parameters HBD (ANK equicrestal -0.23mm; TIU equicrestal -0.51mm; ANK subcrestal +0.19mm; TIU subcrestal -0.57mm) and SLO (ANK equicrestal 35.36 degrees; TIU equicrestal 63.22 degrees; ANK subcrestal 20.40 degrees; TIU subcrestal 44.43 degrees) more pronounced and significant differences were noted. Conclusions: Within the limits of this study, it is concluded that different microgap designs cause different shapes and sizes of the periimplant ('dish-shaped') bone defect in submerged implants both in equicrestal and subcrestal positions.
引用
收藏
页码:1141 / 1147
页数:7
相关论文
共 50 条
  • [11] Influence of premature exposure of implants on early crestal bone loss: an experimental study in dogs
    Yoo, Je-Hyeon
    Choi, Byung-Ho
    Li, Jingxu
    Kim, Han-Sung
    Ko, Chang-Yong
    Xuan, Feng
    Jeong, Seung-Mi
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (06): : 702 - 706
  • [12] Influence of platform switching on crestal bone changes at non-submerged titanium implants: a histomorphometrical study in dogs
    Becker, Juergen
    Ferrari, Daniel
    Herten, Monika
    Kirsch, Axel
    Schaer, Alex
    Schwarz, Frank
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (12) : 1089 - 1096
  • [13] Effects of irradiation in the mandibular bone loaded with dental implants. An experimental study with a canine model
    Padala, Sridhar Reddy
    Asikainen, Pekka
    Ruotsalainen, Timo
    Mikkonen, Jopi Jw
    Silvast, Tuomo S.
    Koistinen, Arto P.
    Schulten, Engelbert A. J. M.
    Ten Bruggenkate, Chris M.
    Kullaa, Arja M.
    ULTRASTRUCTURAL PATHOLOGY, 2021, 45 (4-5) : 276 - 285
  • [14] Peri-implant bone reactions to immediately loaded implants. An experimental study in monkeys
    Romanos, G
    Toh, CG
    Siar, CH
    Swaminathan, D
    Ong, AH
    Donath, K
    Yaacob, H
    Nentwig, GH
    JOURNAL OF PERIODONTOLOGY, 2001, 72 (04) : 506 - 511
  • [15] Healing at Implants Placed in an Alveolar Ridge with a Sloped Configuration: An Experimental Study in Dogs
    Abrahamsson, Ingemar
    Welander, Maria
    Linder, Elena
    Berglundh, Tord
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (01) : 62 - 69
  • [16] Influence of buccal bone lamella defects on hard and soft tissues with submerged and non-submerged healing in immediate implants - an experimental study in minipigs
    Mehl, Christian
    Harder, Soenke
    Zenzen, Leonie
    Naujokat, Hendrik
    Wiltfang, Joerg
    Acil, Yahya
    Kern, Matthias
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2025, 11 (01)
  • [17] Bone reactions to longstanding functional load at implants: an experimental study in dogs
    Berglundh, T
    Abrahamsson, I
    Lindhe, J
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (09) : 925 - 932
  • [18] Osteogenesis at implants without primary bone contact - An experimental study in dogs
    Sivolella, Stefano
    Bressan, Eriberto
    Salata, Luiz A.
    Urrutia, Zoraya A.
    Lang, Niklaus P.
    Botticelli, Daniele
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (05) : 542 - 549
  • [19] Bone healing at implants with different surface configurations: an experimental study in dogs
    Beolchini, Marco
    Lang, Niklaus P.
    Gomez Moreno, Gerardo
    Iezzi, Giovanna
    Botticelli, Daniele
    Calvo Guirado, Jose Luis
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (02) : 196 - 202
  • [20] Healing at implants with and without primary bone contact - An experimental study in dogs
    Scipioni, A
    Bruschi, GB
    Giargia, M
    Berglundh, T
    Lindhe, J
    CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (01) : 39 - 47