Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs

被引:112
|
作者
Weng, Dietmar [1 ]
Hitomi Nagata, Maria Jose [2 ]
Bell, Matthias [1 ]
Bosco, Alvaro Francisco [2 ]
Nascimento de Melo, Luiz Gustavo [2 ]
Richter, Ernst-Juergen [1 ]
机构
[1] Univ Wurzburg, Sch Dent Med, Dept Prosthodont, Wurzburg, Germany
[2] Sao Paulo State Univ Julio de Mesquita Filho UNES, Dept Surg & Integrated Clin, Dent Sch Araccatuba, Div Periodont, Sao Paulo, Brazil
关键词
bone morphology; equicrestal placement; histometric study; microgap; subcrestal placement;
D O I
10.1111/j.1600-0501.2008.01564.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The vertical location of the implant-abutment connection influences the periimplant bone morphology. It is unknown, however, whether different microgap configurations cause different bone reactions. Therefore, in this study the bone morphologies of two different implant systems were compared. Material and methods: Three months after tooth extraction in eight mongrel dogs, two grit-blasted screw implants with internal Morse taper connection (ANK group) were placed on one side whereas the contralateral side received two oxidized screw implants with external hex (TIU group). One implant on each side was placed level with the bone (equicrestal), the second implant was inserted 1.5mm below bone level (subcrestal). After 3 months the implants were uncovered. Three months after stage two surgery, histometrical evaluations were performed in order to assess the periimplant bone levels (PBL), the first bone-to-implant contact points (BICP), the width (HBD) and the steepness (SLO) of the bone defect. Results: All implants osseointegrated clinically and histologically. Bone overgrowth of the microgap was seen in ANK implants only. No significant differences between ANK and TIU could be detected in neither vertical position for PBL and BICP. However, a tendency in favor of ANK was visible when the implants were placed subcrestally. In the parameters HBD (ANK equicrestal -0.23mm; TIU equicrestal -0.51mm; ANK subcrestal +0.19mm; TIU subcrestal -0.57mm) and SLO (ANK equicrestal 35.36 degrees; TIU equicrestal 63.22 degrees; ANK subcrestal 20.40 degrees; TIU subcrestal 44.43 degrees) more pronounced and significant differences were noted. Conclusions: Within the limits of this study, it is concluded that different microgap designs cause different shapes and sizes of the periimplant ('dish-shaped') bone defect in submerged implants both in equicrestal and subcrestal positions.
引用
收藏
页码:1141 / 1147
页数:7
相关论文
共 50 条
  • [1] Influence of Microgap Location and Configuration on Radiographic Bone Loss Around Submerged Implants: An Experimental Study in Dogs
    Weng, Dietmar
    Hitomi Nagata, Maria Jose
    Bosco, Alvaro Francisco
    Nascimento de Melo, Luiz Gustavo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (05) : 941 - 946
  • [2] Influence of Microgap Location and Configuration on Peri-implant Bone Morphology in Nonsubmerged Implants: An Experimental Study in Dogs
    Weng, Dietmar
    Hitomi Nagata, Maria Jose
    Bell, Matthias
    Nascimento de Melo, Luiz Gustavo
    Bosco, Alvaro Francisco
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (03) : 540 - 547
  • [3] Influence of Microgap Location and Configuration on Radiographic Bone Loss in Nonsubmerged Implants: An Experimental Study in Dogs
    Weng, Dietmar
    Hitomi Nagata, Maria Jose
    Leite, Christiane Mota
    Nascimento de Melo, Luiz Gustavo
    Bosco, Alvaro Francisco
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2011, 24 (05) : 445 - 452
  • [4] Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible
    Hermann, JS
    Schoolfield, JD
    Schenk, RK
    Buser, D
    Cochran, DL
    JOURNAL OF PERIODONTOLOGY, 2001, 72 (10) : 1372 - 1383
  • [5] Marginal resorption and periimplant bone quality relation in a 3 and 5 years study with Branemark implants.
    Donado, A
    Peris, R
    Sada, JM
    Donado, M
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1245 - 1245
  • [6] Healing at implants placed in bone of different morphology: an experimental study in dogs
    Caroprese, Marino
    Soldini, Claudio
    Ricci, Sara
    Rea, Massimiliano
    Lang, Niklaus P.
    Botticelli, Daniele
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (08) : 961 - 965
  • [7] Influence of the size of the microgap on crestal bone levels in non-submerged dental implants: A radiographic study in the canine mandible
    King, GN
    Hermann, JS
    Schoolfield, JD
    Buser, D
    Cochran, DL
    JOURNAL OF PERIODONTOLOGY, 2002, 73 (10) : 1111 - 1117
  • [8] Effect of RGD peptide coating of titanium implants on periimplant bone formation in the alveolar crest -: An experimental pilot study in dogs
    Schliephake, H
    Scharnweber, D
    Dard, M
    Rössler, S
    Sewing, A
    Meyer, J
    Hoogestraat, D
    CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) : 312 - 319
  • [9] Early Healing of Nanothickness Bioceramic Coatings on Dental Implants. An Experimental Study in Dogs
    Coelho, Paulo G.
    Cardaropoli, Giuseppe
    Suzuki, Marcelo
    Lemons, Jack E.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 88B (02) : 387 - 393
  • [10] Influence of location on the bone behavior to non-coated and Ca-P coated implants.
    Caulier, H
    Jansen, JA
    Naert, I
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 502 - 502