Ultrasonic Flow Measurement for Pipe Installations with Nonideal Conditions

被引:11
|
作者
Stoker, Devin M. [1 ]
Barfuss, Steven L. [2 ]
Johnson, Michael C. [2 ]
机构
[1] Bowen Collins & Associates, Draper, UT 84020 USA
[2] Utah State Univ, Dept Civil & Environm Engn, Utah Water Res Lab, Logan, UT 84322 USA
关键词
Ultrasonic flow measurement; Water measurement; Irrigation pipeline metering; Computational fluid dynamics;
D O I
10.1061/(ASCE)IR.1943-4774.0000486
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
In the arid Western United States, water is among the most valuable resources. Typically, to successfully and accurately measure a flow rate using most types of flow meters, it is recommended that a straight section of pipe be installed immediately upstream from the flow meter to avoid distorted flow patterns and extreme turbulence at the metering location. In many field piping situations, however, such flow conditions are impossible to achieve. The portable ultrasonic flow meter (USFM) is a commonly used flow meter for field flow measurements in closed conduits and emits two ultrasonic signals across the cross section of pipe. One signal travels with the direction of the flow, and the other travels against the flow. The difference in signal travel time is then used along with the known geometry of the pipe to calculate the average flow velocity of the fluid. The performance of an USFM in nonideal piping scenarios was studied using laboratory experiments and numerical computational fluid dynamics (CFD) models. A transit-time USFM was used downstream of a single 12-in.-long radius elbow, and the error in flow measurement resulting from the flow disturbance was measured. Physical model tests were performed at four locations downstream of the elbow, at three orientations on the circumference of the pipe, and for three flow rates with Reynolds numbers ranging from 250,000 to 750,000. Numerical models were also utilized and the resulting velocity profiles were used to integrate the velocity of the flow across the ultrasonic signal path. The velocity profiles were compared to similar profiles for fully developed flow to determine the error in flow measurement. The USFM measurement errors downstream of the elbow were always negative and were found to be as great as - 16%. A correction curve was applied to the results, which provided a method to correct the ultrasonic flow measurement. By applying the correction equation to the USFM measurements downstream of the elbow, the measurement error was reduced by nearly 90%. It appears that CFD is a viable tool for making appropriate corrections to ultrasonic flow measurements in pipes with upstream flow disturbances. DOI: 10.1061/(ASCE)IR.1943-4774.0000486. (C) 2012 American Society of Civil Engineers.
引用
收藏
页码:993 / 998
页数:6
相关论文
共 50 条
  • [41] FLOW MEASUREMENT USING ULTRASONIC METHOD
    MULTON, F
    HOUILLE BLANCHE-REVUE INTERNATIONALE DE L EAU, 1994, 49 (07): : 30 - 35
  • [42] ULTRASONIC TECHNIQUES FOR MEASUREMENT OF BLOOD FLOW
    FRANKLIN, D
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 175 - &
  • [43] ULTRASONIC BLOOD FLOW MEASUREMENT IN HAEMODIALYSIS
    SAMPSON, D
    PAPADIMITRIOU, M
    KULATILAKE, AE
    BMJ-BRITISH MEDICAL JOURNAL, 1970, 1 (5692): : 340 - +
  • [44] DOPPLER ULTRASONIC MEASUREMENT OF CAROTID FLOW
    MULLER, HR
    RADUE, EW
    SAIA, A
    PALLOTTI, C
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (01): : L91 - L95
  • [45] Ultrasonic measurement of unsteady gas flow
    Dane, HJ
    FLOW MEASUREMENT AND INSTRUMENTATION, 1997, 8 (3-4) : 183 - 190
  • [46] Design Methodology for Supersonic Radial Vanes Operating in Nonideal Flow Conditions
    Anand, Nitish
    Vitale, Salvatore
    Pini, Matteo
    Otero, Gustavo J.
    Pecnik, Rene
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2019, 141 (02):
  • [47] INFLUENCE OF NONIDEAL FLOW CONDITIONS IN HAEMODIALYSERS ON MASS-TRANSFER THEORIES
    KOOIJMAN, JM
    MEDICAL & BIOLOGICAL ENGINEERING, 1973, 11 (05): : 569 - 578
  • [48] MEASUREMENT OF PIPE-FLOW BY AN ELECTROMAGNETIC PROBE
    ZHANG, XZ
    HEMP, J
    ISA TRANSACTIONS, 1994, 33 (02) : 181 - 184
  • [49] PIV measurement of slush nitrogen flow in a pipe
    Takakoshi, T.
    Murakami, M.
    Ikeuchi, M.
    Matsuo, K.
    Tsukahara, R.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 1025 - +
  • [50] Mass flow measurement by means of flow modulation in a pipe section
    Gast, Theodor
    Hoenl, R.
    Koehn, H.
    TM. Technisches Messen, 1988, 55 (7-8) : 261 - 266