MEASUREMENT OF PIPE-FLOW BY AN ELECTROMAGNETIC PROBE

被引:4
|
作者
ZHANG, XZ
HEMP, J
机构
[1] 205 Division, Department of Power Engineering, Nanjing Aeronautical Institute, Nanjing
[2] Department of Fluid Engineering and Instrumentation, School of Mechanical Engineering, Cranfield University, Bedford
关键词
D O I
10.1016/0019-0578(94)90051-5
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electromagnetic (EM) flow velocity probes have some important advantages over normal full scale flow meters when being used in pipe flow measurement. To predict the sensitivity of an electromagnetic probe, with the effect of electrode and magnetic coil arrangement, properties of pipe wall and probe wall, work has been done recently on a mathematical model of an electromagnetic flow velocity probe [1]. This paper gives a brief description of the model. Then the model is used to calculate the pipe wall effect where the pipe wall of different properties is near the sensing head of the probe. The result of the calculation gives a suggested minimum distance between the pipe wall and the electrodes of the probe to keep the error of sensitivity within an accepted degree.
引用
收藏
页码:181 / 184
页数:4