Ultrasonic Flow Measurement for Pipe Installations with Nonideal Conditions

被引:11
|
作者
Stoker, Devin M. [1 ]
Barfuss, Steven L. [2 ]
Johnson, Michael C. [2 ]
机构
[1] Bowen Collins & Associates, Draper, UT 84020 USA
[2] Utah State Univ, Dept Civil & Environm Engn, Utah Water Res Lab, Logan, UT 84322 USA
关键词
Ultrasonic flow measurement; Water measurement; Irrigation pipeline metering; Computational fluid dynamics;
D O I
10.1061/(ASCE)IR.1943-4774.0000486
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
In the arid Western United States, water is among the most valuable resources. Typically, to successfully and accurately measure a flow rate using most types of flow meters, it is recommended that a straight section of pipe be installed immediately upstream from the flow meter to avoid distorted flow patterns and extreme turbulence at the metering location. In many field piping situations, however, such flow conditions are impossible to achieve. The portable ultrasonic flow meter (USFM) is a commonly used flow meter for field flow measurements in closed conduits and emits two ultrasonic signals across the cross section of pipe. One signal travels with the direction of the flow, and the other travels against the flow. The difference in signal travel time is then used along with the known geometry of the pipe to calculate the average flow velocity of the fluid. The performance of an USFM in nonideal piping scenarios was studied using laboratory experiments and numerical computational fluid dynamics (CFD) models. A transit-time USFM was used downstream of a single 12-in.-long radius elbow, and the error in flow measurement resulting from the flow disturbance was measured. Physical model tests were performed at four locations downstream of the elbow, at three orientations on the circumference of the pipe, and for three flow rates with Reynolds numbers ranging from 250,000 to 750,000. Numerical models were also utilized and the resulting velocity profiles were used to integrate the velocity of the flow across the ultrasonic signal path. The velocity profiles were compared to similar profiles for fully developed flow to determine the error in flow measurement. The USFM measurement errors downstream of the elbow were always negative and were found to be as great as - 16%. A correction curve was applied to the results, which provided a method to correct the ultrasonic flow measurement. By applying the correction equation to the USFM measurements downstream of the elbow, the measurement error was reduced by nearly 90%. It appears that CFD is a viable tool for making appropriate corrections to ultrasonic flow measurements in pipes with upstream flow disturbances. DOI: 10.1061/(ASCE)IR.1943-4774.0000486. (C) 2012 American Society of Civil Engineers.
引用
收藏
页码:993 / 998
页数:6
相关论文
共 50 条
  • [1] ULTRASONIC SENSOR AS A MEASUREMENT DEVICE OF AIR FLOW VELOCITY IN THE PIPE
    Suastika, K. G.
    Nawir, M.
    Yunus, P.
    JURNAL PENDIDIKAN FISIKA INDONESIA-INDONESIAN JOURNAL OF PHYSICS EDUCATION, 2013, 9 (02): : 163 - 172
  • [2] INFLUENCE OF PIPE ROUGHNESS ON THE PERFORMANCE OF ULTRASONIC METERS FOR FLOW RATE MEASUREMENT
    Orlando, Alcir de Faro
    Ferreira, Ana Luisa
    Pinheiro, Jose Alberto
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 6, PTS A AND B, 2012, : 757 - 765
  • [3] UNSTEADY-FLOW IN INSTALLATIONS WITH POLYMERIC ADDITIONAL PIPE
    PEZZINGA, G
    SCANDURA, P
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1995, 121 (11): : 802 - 811
  • [4] Theoretical study of elastic effect of a cylindrical pipe wall on ultrasonic flow measurement
    Sun, Yanbing
    Zheng, Congren
    Zhang, Fanyong
    Tan, Xiaodong
    Chen, Kai
    Song, Xin
    Zhang, Xiang
    Chen, Yong
    MEASUREMENT, 2023, 219
  • [5] Turbulent slurry flow measurement using ultrasonic Doppler method in rectangular pipe
    Bares, V.
    Krupicka, J.
    Picek, T.
    Brabec, J.
    Matousek, V.
    EFM13 - EXPERIMENTAL FLUID MECHANICS 2013, 2014, 67
  • [6] Effect of temperature gradient on ultrasonic Doppler velocimetry measurement during pipe flow
    Wang, L
    McCarthy, KL
    McCarthy, MJ
    FOOD RESEARCH INTERNATIONAL, 2004, 37 (06) : 633 - 642
  • [7] Flow Rate Measurement using an Ultrasonic Beam Radiated Perpendicular to a Pipe when Flow Profile Exists
    Igarashi, Juei
    Mizutani, Koichi
    Wakatsuki, Naoto
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1525 - 1528
  • [8] Development of pulse ultrasonic Doppler method for flow rate measurement in power plant multilines flow rate measurement on metal pipe
    Wada, S
    Kikura, H
    Aritomi, M
    Mori, M
    Takeda, Y
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2004, 41 (03) : 339 - 346
  • [9] ULTRASONIC FLOW MEASUREMENT
    BROWN, B
    CHEMICAL AND PROCESS ENGINEERING, 1965, 46 (07): : 365 - &
  • [10] ULTRASONIC FLOW MEASUREMENT
    不详
    PAPER TECHNOLOGY AND INDUSTRY, 1979, 20 (08): : 278 - 278