INFLUENCE OF PIPE ROUGHNESS ON THE PERFORMANCE OF ULTRASONIC METERS FOR FLOW RATE MEASUREMENT

被引:0
|
作者
Orlando, Alcir de Faro [1 ]
Ferreira, Ana Luisa [1 ]
Pinheiro, Jose Alberto [1 ]
机构
[1] Pontif Catholic Univ Rio de Janeiro, Pos Grad Program Metrol PosMQI, Mech Engn Dept DEM, Rio De Janeiro, RJ, Brazil
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Ultrasonic flow meters have been recently used for flow rate measurement because they are a non-intrusive device and have the capability of making diagnostics of their performance and flow field distortion between two consecutive calibrations. The available completely developed flow velocity profiles in the literature is discussed in this paper and integrated along the meter ultrasonic path to simulate its performance. It was shown that for Reynolds number up to 1,000,000 and relatively roughness values smaller than epsilon = 0.00012 the flow is in the hydraulically smooth regime. Also, it was shown that the ratio between the area velocity and the average path velocity (k(h)) decreases close to centerline and increases close to the wall, when roughness increases.
引用
收藏
页码:757 / 765
页数:9
相关论文
共 50 条
  • [1] The uncertainties induced by internal pipe wall roughness on the measurements of clamp-on ultrasonic flow meters
    Gu, Xiaotang
    Cegla, Frederic
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1586 - 1589
  • [2] Development of pulse ultrasonic Doppler method for flow rate measurement in power plant multilines flow rate measurement on metal pipe
    Wada, S
    Kikura, H
    Aritomi, M
    Mori, M
    Takeda, Y
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2004, 41 (03) : 339 - 346
  • [3] Minimizing measurement channels error of ultrasonic flow meters
    Aralov, Oleg V.
    Yarovoy, Artemy T.
    Filippov, Sergey V.
    Buyanov, Ivan V.
    Berezhansky, Nikita V.
    Klyuchnikov, Gleb N.
    NAUKA I TEHNOLOGII TRUBOPROVODNOGO TRANSPORTA NEFTI I NEFTEPRODUKTOV-SCIENCE & TECHNOLOGIES-OIL AND OIL PRODUCTS PIPELINE TRANSPORTATION, 2022, 12 (04): : 376 - 384
  • [4] Investigation of liquid viscosity influence on flow rate measurement by rotary vane meters
    Maslauskas, E.
    Pedisius, N.
    Zygmantas, G.
    MECHANIKA, 2014, (02): : 158 - 164
  • [5] Study on the influence of ultrasonic probes on flow field and measurement performance of ultrasonic flowmeter
    Zhang, Peng-Yong
    Zheng, Dan-Dan
    Xu, Tian-Shi
    Zhang, Li-Xin
    Hu, He-Ming
    Shiyan Liuti Lixue/Journal of Experiments in Fluid Mechanics, 2011, 25 (03): : 60 - 65
  • [6] THE CAPABILITIES OF ULTRASONIC METERS UTILIZATION FOR FLOW MEASUREMENT IN DRAINAGE PIPELINES
    Szejba, Daniel
    Bajkowski, Slawomir
    Pietraszek, Zygmunt
    HYDROLOGIA W INZYNIERII I GOSPODARCE WODNEJ, VOL 1, 2010, (68): : 439 - 449
  • [7] Acoustic Limescale Layer and Temperature Measurement in Ultrasonic Flow Meters
    Landskron, Johannes
    Doetzer, Florian
    Benkert, Andreas
    Mayle, Michael
    Drese, Klaus Stefan
    SENSORS, 2022, 22 (17)
  • [8] Flow Rate Measurement using an Ultrasonic Beam Radiated Perpendicular to a Pipe when Flow Profile Exists
    Igarashi, Juei
    Mizutani, Koichi
    Wakatsuki, Naoto
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1525 - 1528
  • [9] Influence of Different Pipe Bends on Performance of Orifice Meters.
    Orsi, Enrico
    Energia Elettrica, 1978, 55 (01): : 16 - 23
  • [10] Flow rate measurement in a pipe flow by vortex shedding
    Reik, M.
    Hoecker, R.
    Bruzzese, C.
    Hollmach, M.
    Koudal, O.
    Schenkel, T.
    Oertel, H.
    FORSCHUNG IM INGENIEURWESEN-ENGINEERING RESEARCH, 2010, 74 (02): : 77 - 86