INFLUENCE OF PIPE ROUGHNESS ON THE PERFORMANCE OF ULTRASONIC METERS FOR FLOW RATE MEASUREMENT

被引:0
|
作者
Orlando, Alcir de Faro [1 ]
Ferreira, Ana Luisa [1 ]
Pinheiro, Jose Alberto [1 ]
机构
[1] Pontif Catholic Univ Rio de Janeiro, Pos Grad Program Metrol PosMQI, Mech Engn Dept DEM, Rio De Janeiro, RJ, Brazil
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Ultrasonic flow meters have been recently used for flow rate measurement because they are a non-intrusive device and have the capability of making diagnostics of their performance and flow field distortion between two consecutive calibrations. The available completely developed flow velocity profiles in the literature is discussed in this paper and integrated along the meter ultrasonic path to simulate its performance. It was shown that for Reynolds number up to 1,000,000 and relatively roughness values smaller than epsilon = 0.00012 the flow is in the hydraulically smooth regime. Also, it was shown that the ratio between the area velocity and the average path velocity (k(h)) decreases close to centerline and increases close to the wall, when roughness increases.
引用
收藏
页码:757 / 765
页数:9
相关论文
共 50 条
  • [21] BIRGER,GI - ULTRASONIC FLOW METERS
    KANEVSKII, IN
    SOVIET PHYSICS ACOUSTICS-USSR, 1967, 12 (04): : 441 - +
  • [22] A three accelerometer method for the measurement of flow rate in pipe
    Kim, YK
    Kim, YH
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 100 (02): : 717 - 726
  • [23] A three accelerometer method for the measurement of flow rate in pipe
    Ctr. for Noise and Vibration Control, Department of Mechanical Engineering, Korea Adv. Inst. Sci. and Technol., Science Town, Taejon 305-701, Korea, Republic of
    J. ACOUST. SOC. AM., 2 I (717-726):
  • [24] Comparison of flow rate calculation method for ultrasonic flow measurement
    Yu, Yang
    Zong, Guanghua
    Ding, Fenglin
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2013, 39 (01): : 37 - 41
  • [25] FLOW MEASUREMENT WITH BALL FLOW METERS
    SHULMAN, HL
    VANWORMER, KA
    AICHE JOURNAL, 1958, 4 (03) : 380 - 382
  • [26] Proposed method for measurement of flow rate in turbulent periodic pipe flow
    Werzner, E.
    Ray, S.
    Trimis, D.
    13TH EUROPEAN TURBULENCE CONFERENCE (ETC13): WALL-BOUNDED FLOWS AND CONTROL OF TURBULENCE, 2011, 318
  • [27] Investigation of precision sound velocity measurement methods as reference for ultrasonic gas flow meters
    Norli, P
    Lunde, P
    Vestrheim, M
    2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 1443 - 1447
  • [28] Influence of flow disturbances on the performance of industry-standard LNG flow meters
    Kenbar, Asaad
    Schakel, Menne
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 77
  • [29] Measurement of the Flow Rate of Liquids and Gases by Means of Variable Pressure Drop Flow Meters with Flow Straighteners
    Zh. A. Daev
    A. K. Kairakbaev
    Measurement Techniques, 2017, 59 : 1170 - 1174
  • [30] Measurement of the Flow Rate of Liquids and Gases by Means of Variable Pressure Drop Flow Meters with Flow Straighteners
    Daev, Zh A.
    Kairakbaev, A. K.