Automatic Optical Inspection Method for Soft Contact Lenses

被引:2
|
作者
Chang, Chun-Li [1 ]
Wu, Wen-Hong [1 ]
Hwang, Chi-Chun [1 ]
机构
[1] Natl Appl Res Labs, Instrument Technol Res Ctr, Taipei, Taiwan
关键词
image processing; AOI; defect inspection; contact lenses;
D O I
10.1117/12.2182366
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In general, the manufacture of contact lenses is conventionally labor intensive, requiring manual handling and inspection of the cast lens during production. This paper is to build an AOI (automatic optical inspection) system, which include suitable light source, camera and image processing algorithms, for contact lenses defect inspection. The mainly defect type are missing lens and surface defect on the contact lenses. An illumination system with fixed focal lens and charge coupled device (CCD) is used to capture the images of contact lenses. After images are captured, an algorithm is employed to check if there are flaws showed on the images. Five kinds of defect can be detected by the designed algorithm. A prototype of the AOI system for contact lenses inspection is implemented. The experimental result shows that the proposed system is robust for in-line inspection.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Prescribing soft contact lenses for astigmatism
    Morgan, Philip B.
    Efron, Nathan
    CONTACT LENS & ANTERIOR EYE, 2009, 32 (02): : 97 - 98
  • [42] SPOILED SOFT CONTACT-LENSES
    INGRAM, DV
    BRITISH MEDICAL JOURNAL, 1986, 292 (6536): : 1619 - 1619
  • [43] Management of presbyopia with soft contact lenses
    Koffler, BH
    OPHTHALMOLOGICA, 2002, 216 : 34 - 51
  • [44] True History of Soft Contact Lenses
    Michalek, Jiri
    Chmelikova, Dana
    Krumbholcova, Eva Chylikova
    Podesva, Jiri
    Smrckova, Miroslava Duskova
    CHEMICKE LISTY, 2018, 112 (03): : 143 - 147
  • [45] Contact_lenses - The hard and the soft
    不详
    SCIENTIFIC AMERICAN, 2000, 283 (04) : 88 - 89
  • [46] The Safety of Soft Contact Lenses in Children
    Bullimore, Mark A.
    OPTOMETRY AND VISION SCIENCE, 2017, 94 (06) : 638 - 646
  • [47] SOFT CONTACT-LENSES IN KERATOCONUS
    KEMMETMULLER, H
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1977, 97 (APR): : 136 - 137
  • [48] HYDROPHILIC SOFT CONTACT-LENSES
    SHEARER, RV
    CALIFORNIA MEDICINE, 1973, 118 (01): : 30 - 31
  • [49] DISPOSABLE SOFT CONTACT-LENSES
    DRIEBE, WT
    SURVEY OF OPHTHALMOLOGY, 1989, 34 (01) : 44 - 46
  • [50] SPOILED SOFT CONTACT-LENSES
    BUCKLEY, RJ
    BRITISH MEDICAL JOURNAL, 1986, 293 (6540): : 206 - 207