Automatic Optical Inspection Method for Soft Contact Lenses

被引:2
|
作者
Chang, Chun-Li [1 ]
Wu, Wen-Hong [1 ]
Hwang, Chi-Chun [1 ]
机构
[1] Natl Appl Res Labs, Instrument Technol Res Ctr, Taipei, Taiwan
关键词
image processing; AOI; defect inspection; contact lenses;
D O I
10.1117/12.2182366
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In general, the manufacture of contact lenses is conventionally labor intensive, requiring manual handling and inspection of the cast lens during production. This paper is to build an AOI (automatic optical inspection) system, which include suitable light source, camera and image processing algorithms, for contact lenses defect inspection. The mainly defect type are missing lens and surface defect on the contact lenses. An illumination system with fixed focal lens and charge coupled device (CCD) is used to capture the images of contact lenses. After images are captured, an algorithm is employed to check if there are flaws showed on the images. Five kinds of defect can be detected by the designed algorithm. A prototype of the AOI system for contact lenses inspection is implemented. The experimental result shows that the proposed system is robust for in-line inspection.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] DEVELOPMENT OF SOFT CONTACT-LENSES AND THEIR IMPORTANCE IN OPTICAL AND THERAPEUTIC INDICATIONS
    DREIFUS, M
    ANNALES D OCULISTIQUE, 1976, 209 (7-8): : 526 - 526
  • [32] Optical quality and visual performance with customised soft contact lenses for keratoconus
    Jinabhai, Amit
    O'Donnell, Clare
    Tromans, Cindy
    Radhakrishnan, Hema
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2014, 34 (05) : 528 - 539
  • [33] On-eye evaluation of optical performance of rigid and soft contact lenses
    Hong, X
    Himebaugh, N
    Thibos, LN
    OPTOMETRY AND VISION SCIENCE, 2001, 78 (12) : 872 - 880
  • [34] Simulated optical performance of custom wavefront soft contact lenses for keratoconus
    De Brabander, J
    Chateau, N
    Marin, G
    Lopez-Gil, N
    Van der Worp, E
    Benito, A
    OPTOMETRY AND VISION SCIENCE, 2003, 80 (09) : 637 - 643
  • [35] Optical performance of different soft contact lenses based on wavefront analysis
    Fagnani Gatti, Roberta
    Lipener, Cesar
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2008, 71 (06) : 42 - 46
  • [36] Inspection: Fully automatic inspection of mobile phone display lenses
    Wagner, T
    Plankensteiner, P
    KUNSTSTOFFE-PLAST EUROPE, 2003, 93 (01): : 66 - +
  • [37] A method for polished lenses inspection
    Rizescu, Dana
    Rizescu, Ciprian Ion
    International Journal of Mechatronics and Applied Mechanics, 2020, 2 (08): : 63 - 69
  • [38] Automatic optical inspection
    Hofert, Dave
    Evaluation Engineering, 1988, 27 (10):
  • [39] Success with Soft Contact Lenses after Failure of Rigid Contact Lenses in Keratoconus
    Su, Becky
    Yu, Austin
    Chung, Daniel
    Greenstein, Steven
    Gelles, John
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [40] OPTICAL-PROPERTIES OF SOFT CONTACT-LENSES AS A FUNCTION OF THEIR WATER CONCENTRATION
    BAUER, GT
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1979, 69 (10) : 1447 - 1447