OPENED END-TO-SIDE TECHNIQUE FOR END-TO-SIDE ANASTOMOSIS AND ANALYSES BY AN ELASTIC TRUE-TO-SCALE SILICONE RUBBER MODEL

被引:0
|
作者
Muecke, Thomas [1 ]
Ritschl, Lucas M. [1 ]
Balasso, Andrea [2 ]
Wolff, Klaus-Dietrich [1 ]
Mitchell, David A. [1 ]
Liepsch, Dieter [3 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Oral & Maxillofacial Surg, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Neuroradiol, D-81675 Munich, Germany
[3] Munich Univ Appl Sci, Inst Biotech, Munich, Germany
关键词
MICRO-VASCULAR ANASTOMOSIS; CAROTID-ARTERY BIFURCATION; FREE-TISSUE TRANSFER; FREE FLAP TRANSFERS; MICROVASCULAR ANASTOMOSIS; FLOW VISUALIZATION; PULSATILE FLOW; BLOOD-FLOW; VELOCITY; TIME;
D O I
10.1002/micr.22182
中图分类号
R61 [外科手术学];
学科分类号
摘要
The end-to-side anastomosis is frequently used in microvascular free flap transfer, but detailed rheological analyses are not available. The purpose of this study was to introduce a new modified end-to-side (Opened End-to-Side, OES-) technique and compare the resulting flow pattern to a conventional technique. The new technique was based on a bi-triangulated preparation of the branching-vessel end, resulting in a fish-mouthed opening. We performed two different types of end-to-side anastomoses in forty pig coronary arteries and produced one elastic, true-to-scale silicone rubber model of each anastomosis. Then we installed the transparent models in a circulatory experimental setup that simulated the physiological human blood flow. Flow velocity was measured with the one-component Laser-Doppler-Anemometer system, recording flow axial and perpendicular to the model at four defined cross-sections for seven heart cycles in each model. Maximal and minimal axial velocities ranged in the conventional model between 0.269 and -0.122 m/s and in the experimental model between 0.313 and -0.153 m/s. A less disturbed flow velocity distribution was seen in the experimental model distal to the anastomosis. The OES-technique showed superior flow profiles distal to the anastomosis with minor tendencies of flow separation and represents a new alternative for end-to-side anastomosis. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:28 / 36
页数:9
相关论文
共 50 条
  • [41] FREE FLAP TRANSFERS BY END-TO-SIDE ARTERIAL ANASTOMOSIS
    IKUTA, Y
    WATARI, S
    KAWAMURA, K
    SHIMA, R
    MATSUISHI, Y
    MIYOSHI, K
    TSUGE, K
    BRITISH JOURNAL OF PLASTIC SURGERY, 1975, 28 (01): : 1 - 7
  • [42] End-to-side anastomosis in heterotopic rat organ transplantation
    Marni, A
    Ferrero, ME
    Forti, D
    MICROSURGERY, 1996, 17 (01) : 21 - 24
  • [43] Effects of asymmetry on flow conditions in an end-to-side anastomosis
    Jones, Steven
    Kadirvelu, Ushapriya
    Bassiouny, Hisham
    Annals of Biomedical Engineering, 2000, 28 (SUPPL. 1)
  • [44] ARTERIAL HOMOGRAFTS - EXPERIENCE WITH END-TO-SIDE VASCULAR ANASTOMOSIS
    CONN, JH
    SPARKUHL, K
    AMERICAN JOURNAL OF SURGERY, 1957, 94 (05): : 695 - 704
  • [45] End-to-side portacaval shunt:: A simplified technique
    Sanchez-Patan, Fernando
    Blanco, Ruben
    Angeles Aller, Maria
    Anchuelo, Raquel
    San Roman, Fidel
    Arias, Jaime
    JOURNAL OF INVESTIGATIVE SURGERY, 2007, 20 (02) : 135 - 138
  • [46] THE LASER-ASSISTED END-TO-SIDE MICROVASCULAR ANASTOMOSIS
    RUIZRAZURA, A
    LAN, M
    COHEN, BE
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 83 (03) : 511 - 517
  • [47] STAPLING DEVICE FOR END-TO-SIDE ANASTOMOSIS OF BLOOD VESSEL
    INOKUCHI, K
    ARCHIVES OF SURGERY, 1961, 82 (03) : 337 - 341
  • [48] BYPASS ENTERITIS - SIGNIFICANCE OF END-TO-END AND END-TO-SIDE ANASTOMOSIS IN JEJUNOILEOSTOMY
    HUSEMANN, B
    CHIRURG, 1979, 50 (02): : 91 - 95
  • [49] DANGER OF END-TO-SIDE URETERO-COLIC ANASTOMOSIS
    WELLS, C
    BRITISH MEDICAL JOURNAL, 1951, 1 (4714): : 1082 - 1082