OPENED END-TO-SIDE TECHNIQUE FOR END-TO-SIDE ANASTOMOSIS AND ANALYSES BY AN ELASTIC TRUE-TO-SCALE SILICONE RUBBER MODEL

被引:0
|
作者
Muecke, Thomas [1 ]
Ritschl, Lucas M. [1 ]
Balasso, Andrea [2 ]
Wolff, Klaus-Dietrich [1 ]
Mitchell, David A. [1 ]
Liepsch, Dieter [3 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Oral & Maxillofacial Surg, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Neuroradiol, D-81675 Munich, Germany
[3] Munich Univ Appl Sci, Inst Biotech, Munich, Germany
关键词
MICRO-VASCULAR ANASTOMOSIS; CAROTID-ARTERY BIFURCATION; FREE-TISSUE TRANSFER; FREE FLAP TRANSFERS; MICROVASCULAR ANASTOMOSIS; FLOW VISUALIZATION; PULSATILE FLOW; BLOOD-FLOW; VELOCITY; TIME;
D O I
10.1002/micr.22182
中图分类号
R61 [外科手术学];
学科分类号
摘要
The end-to-side anastomosis is frequently used in microvascular free flap transfer, but detailed rheological analyses are not available. The purpose of this study was to introduce a new modified end-to-side (Opened End-to-Side, OES-) technique and compare the resulting flow pattern to a conventional technique. The new technique was based on a bi-triangulated preparation of the branching-vessel end, resulting in a fish-mouthed opening. We performed two different types of end-to-side anastomoses in forty pig coronary arteries and produced one elastic, true-to-scale silicone rubber model of each anastomosis. Then we installed the transparent models in a circulatory experimental setup that simulated the physiological human blood flow. Flow velocity was measured with the one-component Laser-Doppler-Anemometer system, recording flow axial and perpendicular to the model at four defined cross-sections for seven heart cycles in each model. Maximal and minimal axial velocities ranged in the conventional model between 0.269 and -0.122 m/s and in the experimental model between 0.313 and -0.153 m/s. A less disturbed flow velocity distribution was seen in the experimental model distal to the anastomosis. The OES-technique showed superior flow profiles distal to the anastomosis with minor tendencies of flow separation and represents a new alternative for end-to-side anastomosis. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:28 / 36
页数:9
相关论文
共 50 条
  • [21] ARTERIAL END-TO-SIDE ANASTOMOSIS WITH THE UNILINK SYSTEM
    RAGNARSSON, R
    BERGGREN, A
    OSTRUP, LT
    GILBERT, RW
    ANNALS OF PLASTIC SURGERY, 1989, 22 (05) : 405 - 415
  • [22] INDICATIONS FOR AND TECHNIQUE OF END-TO-SIDE GASTRODUODENOSTOMY
    FARTHMANN, E
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1975, 339 : 725 - 725
  • [23] VESSEL WALL RESPONSE TO END-TO-SIDE ANASTOMOSIS
    MEHDORN, HM
    WEINSTEIN, PR
    CHATER, NL
    STROKE, 1978, 9 (01) : 104 - 104
  • [24] Use of a micropunch for arteriotomy in end-to-side anastomosis
    Hallock, GG
    Rice, DC
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 1996, 12 (01) : 59 - 62
  • [25] Tips and tricks for end-to-side anastomosis arteriotomies
    El Rifai, Sebastien
    Boudard, Julien
    Haiun, Mathieu
    Obert, Laurent
    Pauchot, Julien
    HAND SURGERY & REHABILITATION, 2016, 35 (02): : 85 - 94
  • [26] END-TO-SIDE MESENTERICOCAVAL ANASTOMOSIS ON RIGHT SIDE ABOVE MESOCOLON
    LATASTE, J
    NOUVELLE PRESSE MEDICALE, 1972, 1 (20): : 1367 - &
  • [27] PROXIMAL ANASTOMOSIS IN AORTOBIFEMORAL BYPASS - END-TO-END OR END-TO-SIDE
    MELLIERE, D
    LABASTIE, J
    BECQUEMIN, JP
    KASSAB, M
    PARIS, E
    JOURNAL OF CARDIOVASCULAR SURGERY, 1990, 31 (01): : 77 - 80
  • [28] End-to-side anastomosis of peripheral nerve in experimental and clinical model
    Haninec, P
    Dubovy, P
    Sámal, F
    Houst'ava, L
    Stejskal, L
    DEVELOPMENTS IN NEUROSCIENCES, 2004, 1259 : 471 - 477
  • [29] Comparison of a distal end-to-side neurorrhaphy with a proximal–distal end-to-side neurorrhaphy: in a rat model
    Hosseinian M.A.
    Gharibi Loron A.
    Nemati B.
    Khandaghy M.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (8) : 1261 - 1264
  • [30] End-to-side neurorrhaphy
    Zhang, F
    Fischer, KA
    MICROSURGERY, 2002, 22 (03) : 122 - 127