Continuous-flow/stopped-flow system incorporating a rotating bioreactor for the determination of penicillins in pharmaceutical products

被引:5
|
作者
Lapierre, AV [1 ]
Olsina, RA [1 ]
Raba, J [1 ]
机构
[1] Natl Univ San Luis, Dept Analyt Chem, San Luis, Argentina
关键词
bioreactor; penicillins; penicillinase; flow system biosensors;
D O I
10.1016/S0003-2670(99)00445-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rotating enzyme-immobilized reactor and a flat pH electrode have been incorporated into a sealed cell for use under continuous-flow/stopped-flow operation. The system has been used for rapid determination of penicillins G and V in pharmaceutical tablets and injectables. Detections based on the increase of hydrogen ion concentration due to enzymatic hydrolysis of the penicillins by the enzyme penicillinase [EC 3.5.2.6] immobilized on controlled-pore glass. Selective determination of the analyte in the 0.001-0.50 mM concentration range can be accomplished at the rate of 30 samples h(-1). (C)1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 50 条
  • [21] STOPPED-FLOW PHOTOMETRIC-DETERMINATION OF CLAVULANIC ACID IN PHARMACEUTICAL AND SERUM SAMPLES
    IZQUIERDO, P
    GOMEZHENS, A
    PEREZBENDITO, D
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (10) : 927 - 931
  • [22] Determination of piroxicam in pharmaceutical preparations by continuous-flow chemiluminescence
    Murillo Pulgarin, J. A.
    Alanon Molina, A.
    Boras, N.
    ANALYTICAL METHODS, 2010, 2 (01) : 76 - 81
  • [23] STOPPED-FLOW, AIR-SEGMENTED CONTINUOUS-FLOW - KINETIC DETERMINATIONS OF GLUCOSE AND PHOSPHATE IN WINE AND SERUM SAMPLES
    HSIEH, YS
    CROUCH, SR
    ANALYTICA CHIMICA ACTA, 1993, 284 (01) : 159 - 166
  • [24] DETERMINATION OF THE DEAD TIME OF A STOPPED-FLOW FLUOROMETER
    BRISSETTE, P
    BALLOU, DP
    MASSEY, V
    ANALYTICAL BIOCHEMISTRY, 1989, 181 (02) : 234 - 238
  • [25] Use of stopped-flow fluoroimmunoassay in pesticide determination
    Matveeva, EG
    AguilarCaballos, MP
    Eremin, SA
    GomezHens, A
    PerezBendito, D
    ANALYST, 1997, 122 (08) : 863 - 866
  • [26] A SIMPLE STOPPED-FLOW METHOD WITH CONTINUOUS PUMPING FOR THE SPECTROPHOTOMETRIC FLOW-INJECTION DETERMINATION OF BORON IN PLANTS
    ARRUDA, MAZ
    ZAGATTO, EAG
    ANALYTICA CHIMICA ACTA, 1987, 199 : 137 - 145
  • [27] Catalytic determination of rhodium in a continuous-flow system
    Khomutova, EG
    Rysev, AP
    Fedorina, LI
    JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 52 (07) : 683 - 686
  • [28] IMPROVED ESTRIOL DETERMINATION IN A CONTINUOUS-FLOW SYSTEM
    LEVER, M
    POWELL, JC
    PEACE, SM
    BIOCHEMICAL MEDICINE, 1973, 8 (02): : 188 - 198
  • [29] DETERMINATION OF ARSENIC IN A NICKEL-BASED ALLOY BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY INCORPORATING CONTINUOUS-FLOW MATRIX-ISOLATION AND STOPPED-FLOW PRE-REDUCTION PROCEDURES
    TYSON, JF
    OFFLEY, SG
    SEARE, NJ
    KIBBLE, HAB
    FELLOWS, C
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) : 315 - 322
  • [30] RAPID STOPPED-FLOW MICROWAVE DIGESTION SYSTEM
    KARANASSIOS, V
    LI, FH
    LIU, B
    SALIN, ED
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (06) : 457 - 463