High-Pitch ECG-Synchronized Pulmonary CT Angiography Versus Standard CT Pulmonary Angiography: A Prospective Randomized Study

被引:16
|
作者
Bolen, Michael A. [1 ,2 ]
Renapurkar, Rahul D. [1 ]
Popovic, Zoran B. [1 ]
Heresi, Gustavo A. [3 ]
Flamm, Scott D. [2 ]
Lau, Charles T. [1 ]
Halliburton, Sandra S. [1 ,2 ]
机构
[1] Cleveland Clin, Imaging Inst, Cardiovasc Imaging Lab, Cleveland, OH 44195 USA
[2] Cleveland Clin, Inst Heart & Vasc, Cleveland, OH 44195 USA
[3] Cleveland Clin, Resp Inst, Cleveland, OH 44195 USA
关键词
CT angiography; high pitch; pulmonary embolism; EMBOLISM; MANAGEMENT;
D O I
10.2214/AJR.13.10597
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare high-pitch ECG-synchronized pulmonary CT angiography (CTA) with standard pulmonary CTA with regard to radiation dose and image quality in patients with suspected pulmonary embolism. SUBJECTS AND METHODS. This prospective study was approved by the institutional review board, and participants provided informed consent. Patients with suspected pulmonary embolism (60% women; mean age, 57 +/- 14 years) were randomized to undergo highpitch ECG-synchronized pulmonary CTA (n = 26) or standard pulmonary CTA (n = 21). Two independent readers assessed subjective image quality of pulmonary arteries, cardiovascular structures, and pulmonary parenchyma. Signal intensity (SI) was measured in one segmental and three central pulmonary arteries. RESULTS. High-pitch ECG-synchronized pulmonary CTA showed higher SI (p < 0.001) for pulmonary arteries. Image quality scores indicated improvement in assessment of cardiovascular structures (p < 0.001), minimization of motion of central (p < 0.001) pulmonary arteries, and an increase in pulmonary arterial enhancement (p = 0.01) with high-pitch ECG-synchronized pulmonary CTA. Image quality scores for lung assessment were higher for standard pulmonary CTA (p < 0.001). The amount of contrast agent administered was similar between techniques (p = 0.86). Radiation dose was lower for high-pitch ECG-synchronized pulmonary CTA (p < 0.001). CONCLUSION. High-pitch ECG-synchronized pulmonary CTA provides higher pulmonary arterial SI, decreased motion of central pulmonary arteries, and improved assessment of cardiovascular structures with similar contrast dose and lower radiation compared with standard pulmonary CTA.
引用
收藏
页码:971 / 976
页数:6
相关论文
共 50 条
  • [21] Highly accelerated, Dixon-based non-contrast MR angiography versus high-pitch CT angiography
    Martin Georg Zeilinger
    Daniel Giese
    Michaela Schmidt
    Matthias Stefan May
    Rolf Janka
    Rafael Heiss
    Fabian Ammon
    Stephan Achenbach
    Michael Uder
    Christoph Treutlein
    La radiologia medica, 2024, 129 : 268 - 279
  • [22] Radiation Dose and Image Quality at High-Pitch CT Angiography of the Aorta: Intraindividual and Interindividual Comparisons With Conventional CT Angiography
    Apfaltrer, Paul
    Hanna, E. Lexworth
    Schoepf, U. Joseph
    Spears, J. Reid
    Schoenberg, Stefan O.
    Fink, Christian
    Vliegenthart, Rozemarijn
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1402 - 1409
  • [23] Prospectively ECG Gated CT pulmonary angiography versus helical ungated CT pulmonary angiography: Impact on cardiac related motion artifacts and patient radiation dose
    Shuman, William P.
    Leipsic, Jonathon A.
    Busey, Janet M.
    Green, Douglas E.
    Pipavath, Sudhakar N.
    Hague, Cameron J.
    Koprowicz, Kent M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2444 - 2449
  • [24] ECG-Synchronized CT Angiography in 324 Consecutive Pediatric Patients: Spectrum of Indications and Trends in Radiation Dose
    Meinel, Felix G.
    Henzler, Thomas
    Schoepf, U. Joseph
    Park, Patsy W.
    Huda, Walter
    Spearman, James V.
    Dyer, Kevin T.
    Rao, Anil G.
    Hlavacek, Anthony M.
    PEDIATRIC CARDIOLOGY, 2015, 36 (03) : 569 - 578
  • [25] ECG-Synchronized CT Angiography in 324 Consecutive Pediatric Patients: Spectrum of Indications and Trends in Radiation Dose
    Felix G. Meinel
    Thomas Henzler
    U. Joseph Schoepf
    Patsy W. Park
    Walter Huda
    James V. Spearman
    Kevin T. Dyer
    Anil G. Rao
    Anthony M. Hlavacek
    Pediatric Cardiology, 2015, 36 : 569 - 578
  • [26] Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography
    Liu, Jie
    Gao, Jianbo
    Wu, Runze
    Zhang, Yonggao
    Hu, Lili
    Hou, Ping
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05): : 1115 - 1120
  • [27] High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    Beeres, Martin
    Schell, Boris
    Mastragelopoulos, Aristidis
    Herrmann, Eva
    Kerl, Josef Matthias
    Gruber-Rouh, Tatjana
    Lee, Clara
    Siebenhandl, Petra
    Bodelle, Boris
    Zangos, Stephan
    Vogl, Thomas J.
    Jacobi, Volkmar
    Bauer, Ralf W.
    EUROPEAN RADIOLOGY, 2012, 22 (01) : 129 - 137
  • [28] High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    Martin Beeres
    Boris Schell
    Aristidis Mastragelopoulos
    Eva Herrmann
    Josef Matthias Kerl
    Tatjana Gruber-Rouh
    Clara Lee
    Petra Siebenhandl
    Boris Bodelle
    Stephan Zangos
    Thomas J. Vogl
    Volkmar Jacobi
    Ralf W. Bauer
    European Radiology, 2012, 22 : 129 - 137
  • [29] Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography
    Jie Liu
    Jianbo Gao
    Runze Wu
    Yonggao Zhang
    Lili Hu
    Ping Hou
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1115 - 1120
  • [30] Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience
    Wang, Q.
    Qin, J.
    He, B.
    Zhou, Y.
    Yang, J-J
    Hou, X. -L.
    Yang, X. -B.
    Chen, J. -H.
    Chen, Y. -D.
    CLINICAL RADIOLOGY, 2013, 68 (08) : 792 - 798