A quantitative method for evaluating inferior glenohumeral joint stiffness using ultrasonography

被引:3
|
作者
Tsai, Wen-Wei [1 ]
Lee, Ming-Yih [1 ]
Yeh, Wen-Lin [2 ]
Cheng, Shih-Chung [3 ]
Soon, Kok-Soon [4 ]
Lei, Kin Fong [1 ]
Lin, Wen-Yen [5 ]
机构
[1] Chang Gung Univ, Grad Inst Med Mechatron, Tao Yuan 333, Taiwan
[2] Chang Gung Mem Hosp, Dept Orthoped, Tao Yuan, Taiwan
[3] Natl Taiwan Sport Univ, Grad Inst Coaching Sci, Guishan Township, Taiwan
[4] Chang Gung Univ, Dept Mech Engn, Tao Yuan 333, Taiwan
[5] Chang Gung Univ, Dept Elect Engn, Tao Yuan 333, Taiwan
关键词
Shoulder; Laxity; Stiffness; Ultrasonography; Subluxation; SHOULDER SUBLUXATION; ASYMPTOMATIC SHOULDERS; HUMERUS TRANSLATION; HEMIPLEGIA; ABDUCTION; LAXITY; PAIN;
D O I
10.1016/j.medengphy.2011.10.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Subluxation of the affected shoulder in post-stroke patients is associated with nerve disorders and muscle fatigue. Clinicians must be able to accurately and reliably measure inferior glenohumeral subluxation in patients to provide appropriate treatment. However, quantitative methods for evaluating the laxity and stiffness of the glenohumeral joint (GHJ) are still being developed. The aim of this study was to develop a new protocol for evaluating the laxity and stiffness of the inferior GHJ using ultrasonography under optimal testing conditions and to investigate changes in the GHJ from a commercially available humerus brace and shoulder brace. Multistage inferior displacement forces were applied to create a glide between the most cephalad point on the visible anterosuperior surface of the humeral head and coracoid process in seven healthy volunteers. GHJ stiffness was defined as the slope of the linear regression line between the glides and different testing loads. The testing conditions were defined by different test loading mechanisms (n = 2), shoulder constraining conditions (n = 2), and loading modes (n = 4). The optimal testing condition was defined as the condition with the least residual variance of measured laxity to the calculated stiffness under different testing loads. A paired t-test was used to compare the laxity and stiffness of the inferior GHJ using different braces. No significant difference was identified between the two test loading mechanisms (t = 0.218, p = 0.831) and two shoulder constraining conditions (t = -0.235, p = 0.818). We concluded that ultrasonographic laxity measurements performed using a pulley set loading mechanism was as reliable as direct loading. Additionally, constraining the unloaded shoulder was proposed due to the lower mean residual variance value. Moreover, pulling the elbow downward with loading on the upper arm was suggested, as pulling the elbow downward with the elbow flexed and loading on the forearm may overestimate stiffness and pain in the inferior GHJ at the loading point due to friction between the wide belt and skin. Furthermore, subjects wearing a humerus brace with a belt, which creates the effect of lifting the humerus toward the acromion, had greater GHJ stiffness compared to subjects wearing a shoulder brace without a belt to lift the humerus under the proposed testing conditions. This study provides experimental evidence that shoulder braces may reduce GHJ laxity under an external load, implying that the use of a humeral brace can prevent subluxation in post-stroke patients. The resulting optimal testing conditions for measuring the laxity and stiffness of the GHJ is to constrain the unloaded shoulder and bend the loaded arm at the elbow with loading on the upper arm using a pulley system. (C) 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:236 / 240
页数:5
相关论文
共 50 条
  • [41] Specimen-Specific Method for Quantifying Glenohumeral Joint Kinematics
    Yeon Soo Lee
    Thay Q. Lee
    Annals of Biomedical Engineering, 2010, 38 : 3226 - 3236
  • [42] Specimen-Specific Method for Quantifying Glenohumeral Joint Kinematics
    Lee, Yeon Soo
    Lee, Thay Q.
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (10) : 3226 - 3236
  • [43] A method of estimating normal stiffness of joint
    Wang, Shijun
    Zhao, Jinjuan
    Zhang, Huijun
    Gou, Peng
    Ma, Jingzhi
    Huang, Yumei
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2011, 47 (21): : 111 - 115
  • [44] Quantitative measurement of spastic ankle joint stiffness using a manual device: A preliminary study
    Kobayashi, Toshiki
    Leung, Aaron K. L.
    Akazawa, Yasushi
    Tanaka, Masao
    Hutchins, Stephen W.
    JOURNAL OF BIOMECHANICS, 2010, 43 (09) : 1831 - 1834
  • [45] A Straightforward 3-Step Method for Identifying the Sacroiliac Joint Using Ultrasonography
    Ekici, Burak
    Yildizgoren, Mustafa Turgut
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (10) : 2233 - 2234
  • [46] Open Inferior glenohumeral joint dislocation with complete range of motion recovery: Case Report and literature review
    Saavedra-Islas, Noe
    Meza-Camacho, Jorge
    Padilla-Medina, Jose Ramon
    Villarreal-Villarreal, Gregorio Alejandro
    Pena-Martinez, Victor M.
    Acosta-Olivo, Carlos Alberto
    SHOULDER & ELBOW, 2022, 14 (06) : 663 - 667
  • [47] Hemodynamic Instability After Axillary Artery Rupture Following Inferior Glenohumeral Joint Dislocation: A Case Report
    Rasmussen, Alexander Bech
    Thorninger, Rikke
    Waever, Daniel
    AMERICAN JOURNAL OF CASE REPORTS, 2023, 24
  • [48] Low back pain, the stiffness of the sacroiliac joint: A new method using ultrasound
    Vlaanderen, E
    Conza, NE
    Snijders, CJ
    Bouakaz, A
    De Jong, N
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (01): : 39 - 44
  • [49] Quantitative Method for Evaluating the Coordination between Sprinting Motions using Joint Coordinates Obtained from the Videos and Cross-correlations
    Sabanai, Masato
    Seo, Chanjin
    Ogata, Hiroyuki
    Ohya, Jun
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION APPLICATIONS AND METHODS (ICPRAM), 2021, : 531 - 539
  • [50] INDOMETHACIN IN ACUTE GOUT USING A NEW METHOD OF EVALUATING JOINT INFLAMMATION
    SMYTH, CJ
    VALAYOS, EE
    AMOROSO, C
    ARTHRITIS AND RHEUMATISM, 1963, 6 (03): : 299 - &