Acute haemodynamic effects of intra-aortic balloon pump and cardiac resynchronization therapy

被引:2
|
作者
Bonanno, Carlo [1 ]
Ometto, Renato [1 ]
La Vecchia, Luigi [1 ]
Fontanelli, Alessandro [1 ]
机构
[1] San Bortolo Hosp, I-36100 Vicenza, Italy
关键词
cardiac resynchronization therapy; heart failure; haemodynamics; intra-aortic balloon pump;
D O I
10.2459/JCM.0b013e3282f2ccef
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report two cases in which intra-aortic balloon pump (IABP) was used successfully as a bridge to. cardiac resynchronization therapy (CRT) to treat patients with refractory systolic heart failure. The study was designed to assess the acute haemodynamic effects of IABP coupled with CRT using standard haemodynamic monitoring. In both cases, a marked elevation of V-wave in pulmonary capillary wedge pressure (PCWP) was shown, and a moderate-to-severe functional mitral regurgitation was observed. IABP and CRT resulted in a significant acute improvement in aortic pressure, PCWP, and V-wave amplitude compared with baseline measurements and IABP alone. These results provide a basis for studies examining the haemodynamic effects of IABP support associated with CRT in patients with heart failure refractory to medical therapy.
引用
收藏
页码:719 / 724
页数:6
相关论文
共 50 条
  • [41] VASCULAR COMPLICATIONS OF PERCUTANEOUS AXILLARY INTRA-AORTIC BALLOON PUMP THERAPY
    Nishida, Hidefumi
    Song, Tae
    Onsager, David
    Ann Nguyen
    Grinstein, Jonathan
    Chung, Bow
    Smith, Bryan
    Kalantari, Sara
    Sarswat, Nitasha
    Kim, Gene
    Pinney, Sean
    Jeevanandam, Valluvan
    Milner, Ross
    Ota, Takeyoshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 642 - 642
  • [42] HEMODYNAMIC-EFFECTS OF THE INTRA-AORTIC BALLOON PUMP DURING EXPERIMENTAL CARDIAC-ARREST
    EMERMAN, CL
    PINCHAK, AC
    HAGEN, JF
    HANCOCK, D
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1989, 7 (04): : 378 - 383
  • [43] Intra-aortic balloon counterpulsation therapy
    Albertus, S
    CRITICAL CARE NURSE, 2006, 26 (01) : 14 - 14
  • [44] Intra-aortic balloon pump microperforation resulting in balloon entrapment
    Warrillow, S. J.
    Fealy, N. G.
    Houston, S. A.
    ANAESTHESIA AND INTENSIVE CARE, 2008, 36 (06) : 916 - 917
  • [45] Contemporary outcomes of cardiac surgery patients supported by the intra-aortic balloon pump
    Lorusso, Roberto
    Heuts, Samuel
    Jiritano, Federica
    Scrofani, Roberto
    Antona, Carlo
    Dato, Guglielmo Actis
    Centofanti, Paolo
    Ferrarese, Sandro
    Matteuci, Matteo
    Miceli, Antonio
    Glauber, Mattia
    Vizzardi, Enrico
    Sponga, Sandro
    Vendramin, Igor
    Garatti, Andrea
    de Vincentis, Carlo
    De Bonis, Michele
    Ajello, Silvia
    Troise, Giovanni
    Dalla Tomba, Margherita
    Serraino, Filiberto
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2022, 35 (01)
  • [46] Determinants of Cardiac Index Improvement after Intra-Aortic Balloon Pump Insertion
    Castagna, F.
    Chalhoub, G.
    Ippolito, P.
    Saeed, O.
    Sims, D.
    Jorde, U.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S351 - S352
  • [47] Complications related to intra-aortic balloon pump in cardiac surgery: A decade later
    Elahi, MM
    Chetty, GK
    Kirke, R
    Azeem, T
    Hartshorne, R
    Spyt, TJ
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2005, 29 (06) : 591 - 594
  • [48] Outcomes with intra-aortic balloon pump in high risk cardiac surgery patients
    Moursi, Ihab M.
    El Fakharany, Karim
    CHIRURGIA-ITALY, 2019, 32 (03): : 105 - 109
  • [49] INDICATIONS FOR ELECTIVE USE OF INTRA-AORTIC BALLOON PUMP IN CARDIAC-SURGERY
    BOLOOKI, H
    WILLIAMS, W
    VARGAS, A
    KAISER, G
    GHAHRAMANI, A
    CLINICAL RESEARCH, 1975, 23 (03): : A173 - A173
  • [50] Cardiac output by thermodilution and the MostCare system in patients on intra-aortic balloon pump
    A Faltoni
    F Franchi
    E Bigio
    M Romano
    P Giomarelli
    B Biagioli
    S Scolletta
    Critical Care, 13 (Suppl 1):