Contemporary outcomes of cardiac surgery patients supported by the intra-aortic balloon pump

被引:5
|
作者
Lorusso, Roberto [1 ,2 ,3 ]
Heuts, Samuel [1 ]
Jiritano, Federica [4 ]
Scrofani, Roberto [5 ]
Antona, Carlo [5 ]
Dato, Guglielmo Actis [6 ]
Centofanti, Paolo [6 ]
Ferrarese, Sandro [7 ]
Matteuci, Matteo [7 ]
Miceli, Antonio [8 ]
Glauber, Mattia [8 ]
Vizzardi, Enrico [3 ]
Sponga, Sandro [9 ]
Vendramin, Igor [9 ]
Garatti, Andrea [10 ]
de Vincentis, Carlo [10 ]
De Bonis, Michele [11 ]
Ajello, Silvia [12 ]
Troise, Giovanni [13 ]
Dalla Tomba, Margherita [13 ]
Serraino, Filiberto [4 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Cardiothorac Surg, NL-6229 HX Maastricht, Netherlands
[2] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[3] AO Spedali Civili, Dept Cardiac Surg, Brescia, Italy
[4] Osped Univ, Dept Cardiac Surg, Catanzaro, Italy
[5] Osped L Sacco, Dept Cardiac Surg, Milan, Italy
[6] Osped Mauriziano Umberto 1, Dept Cardiac Surg, Turin, Italy
[7] Osped Circolo Varese, Dept Cardiac Surg, Varese, Italy
[8] Ist Clin S Ambrogio, Dept Cardiac Surg, Milan, Italy
[9] Ospediale S Maria della Misericordia, Dept Cardiac Surg, Udine, Italy
[10] Osped S Donato, Dept Cardiac Surg, Milan, Italy
[11] Osped San Raffaele, Dept Cardiac Surg, Milan, Italy
[12] IRCCS San Raffaele Sci Inst, Dept Anesthesia & Intens Care, Milan, Italy
[13] Osped Poliambulanza, Dept Cardiac Surg, Brescia, Italy
关键词
Intra-aortic balloon pump; Cardiac surgery; Postcardiomy shock; Mechanical circulatory support; VASCULAR COMPLICATIONS; COUNTER-PULSATION; COUNTERPULSATION; EFFICACY;
D O I
10.1093/icvts/ivac091
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Although the intra-aortic balloon pump (IABP) has been the most widely adopted temporary mechanical support device in cardiac surgical patients, its use has declined. The current study aimed to evaluate the occurrence and predictors of early mortality and complication rates in contemporary cardiac surgery patients supported by an IABP. METHODS: A multicentre, retrospective analysis was performed of all consecutive cardiac surgical patients receiving perioperative balloon pump support in 8 centres between January 2010 to December 2019. The primary outcome was early mortality, and secondary outcomes were balloon-associated complications. A multivariable binary logistic regression model was applied to evaluate predictors of the primary outcome. RESULTS: The study cohort consisted of 2615 consecutive patients. The median age was 68 years [25th percentile 61, 75th percentile 75 years], with the majority being male (76.9%), and a mean calculated 30-day mortality risk of 10.0%. Early mortality was 12.7% (n = 333), due to cardiac causes (n = 266), neurological causes (=22), balloon-related causes (n = 5) and other causes (n = 40). A composite end point of all vascular complications occurred in 7.2% of patients, and leg ischaemia was observed in 1.3% of patients. The most important predictors of early mortality were peripheral vascular disease [odds ratio (OR) 1.63], postoperative dialysis requirement (OR 10.40) and vascular complications (OR 2.57). CONCLUSIONS: The use of the perioperative IABP proved to be safe and demonstrated relatively low complication rates, particularly for leg ischaemia. As such, we believe that specialists should not be held back to use this widely available treatment in high-risk cardiac surgical patients when indicated.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Early outcomes of intra-aortic balloon pump in cardiac surgery
    Hashemzadeh, K.
    Hashemzadeh, S.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2012, 53 (03): : 387 - 392
  • [2] Outcomes with intra-aortic balloon pump in high risk cardiac surgery patients
    Moursi, Ihab M.
    El Fakharany, Karim
    CHIRURGIA-ITALY, 2019, 32 (03): : 105 - 109
  • [3] EXPERIENCE WITH THE INTRA-AORTIC BALLOON PUMP IN CARDIAC-SURGERY
    FRANK, G
    RIEDELT, R
    BORST, HG
    THORACIC AND CARDIOVASCULAR SURGEON, 1982, 30 (01): : 32 - 33
  • [4] A survey on the use of intra-aortic balloon pump in cardiac surgery
    Bignaini, Elena
    Tritapepe, Luigi
    Pasin, Laura
    Meroni, Roberta
    Corno, Laura
    Testa, Valentina
    Landoni, Giovanni
    Guarracino, Fabio
    Zangrillo, Alberto
    ANNALS OF CARDIAC ANAESTHESIA, 2012, 15 (04) : 274 - +
  • [5] Mortality in patients supported by intra-aortic balloon pump in the course of cardiac surgery was related to perioperative myocardial infarction
    Aksnes, J
    Abdelnoor, M
    Platou, ES
    Fjeld, NB
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1996, 10 (06) : 408 - 411
  • [6] Intra-aortic balloon pump in heart surgery
    Engin, Mesut
    Onur, Tugba
    Onur, Anil
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2024, 72 (06) : 426 - 427
  • [7] The application of intra-aortic balloon pump in cardiac surgery: Result of a survey
    Zhou, Hongyan
    Du, Yu
    Feng, Xue
    Cao, Fangfang
    Zhang, Haitao
    CARDIOLOGY, 2013, 126 : 119 - 119
  • [8] USE OF INTRA-AORTIC BALLOON PUMP IN CARDIAC SURGERY: ANALYSIS OF THE CARDIAC SURGERY REGISTER ARIAM
    Trujillo-Garcia, E.
    Munoz-Bono, J.
    Gomez-Gallego, G.
    Curiel-Balsera, E.
    Mora-Ordonez, J.
    Martinez-Gonzalez, M. C.
    INTENSIVE CARE MEDICINE, 2014, 40 : S115 - S115
  • [9] Levosimendan Versus an Intra-aortic Balloon Pump in Adult Cardiac Surgery Patients With Low Cardiac Output
    Elahi, Maqsood M.
    Lam, Jimmy
    Asopa, Sanjay
    Matata, Bashir M.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (06) : 1154 - 1162
  • [10] The Intra-Aortic Balloon Pump
    Gajanan, Ganesh
    Brilakis, Emmanouil S.
    Siller-Matula, Jolanta M.
    Zolty, Ronald L.
    Velagapudi, Poonam
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (168): : 1 - 12