机构:
Univ Nebraska Med Ctr, Div Cardiovasc Med, Omaha, NE 68198 USAUniv Nebraska Med Ctr, Div Cardiovasc Med, Omaha, NE 68198 USA
Gajanan, Ganesh
[1
]
Brilakis, Emmanouil S.
论文数: 0引用数: 0
h-index: 0
机构:
Minneapolis Heart Inst, Minneapolis, MN USAUniv Nebraska Med Ctr, Div Cardiovasc Med, Omaha, NE 68198 USA
Brilakis, Emmanouil S.
[2
]
Siller-Matula, Jolanta M.
论文数: 0引用数: 0
h-index: 0
机构:
Med Univ Vienna, Div Cardiol, Dept Internal Med 2, Vienna, Austria
Med Univ Warsaw, Dept Expt & Clin Pharmacol, Ctr Preclin Res & Technol CEPT, Warsaw, PolandUniv Nebraska Med Ctr, Div Cardiovasc Med, Omaha, NE 68198 USA
Siller-Matula, Jolanta M.
[3
,4
]
Zolty, Ronald L.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Nebraska Med Ctr, Div Cardiovasc Med, Omaha, NE 68198 USAUniv Nebraska Med Ctr, Div Cardiovasc Med, Omaha, NE 68198 USA
Zolty, Ronald L.
[1
]
Velagapudi, Poonam
论文数: 0引用数: 0
h-index: 0
机构:
Univ Nebraska Med Ctr, Div Cardiovasc Med, Omaha, NE 68198 USAUniv Nebraska Med Ctr, Div Cardiovasc Med, Omaha, NE 68198 USA
Velagapudi, Poonam
[1
]
机构:
[1] Univ Nebraska Med Ctr, Div Cardiovasc Med, Omaha, NE 68198 USA
[2] Minneapolis Heart Inst, Minneapolis, MN USA
[3] Med Univ Vienna, Div Cardiol, Dept Internal Med 2, Vienna, Austria
[4] Med Univ Warsaw, Dept Expt & Clin Pharmacol, Ctr Preclin Res & Technol CEPT, Warsaw, Poland
Cardiogenic shock remains one of the most challenging clinical syndromes in modern medicine. Mechanical support is being increasingly used in the management of cardiogenic shock. Intra-aortic balloon pump (IABP) is one of the earliest and most widely used types of mechanical circulatory support. The device acts by external counterpulsation and uses systolic unloading and diastolic augmentation of aortic pressure to improve hemodynamics. Although IABP provides less hemodynamic support when compared with newer mechanical circulatory support devices, it can still be the mechanical support device of choice in appropriate situations because of its relative simplicity of insertion and removal, need for smaller size vascular access and better safety profile. In this review, we discuss the equipment, procedural and technical aspects, hemodynamic effects, indications, evidence, current status and recent advances in the use of IABP in cardiogenic shock.
机构:
Kasugai Municipal Hosp, Div Cardiovasc Surg, Kasugai, Aichi 4868510, JapanKasugai Municipal Hosp, Div Cardiovasc Surg, Kasugai, Aichi 4868510, Japan
Takami, Y
Masumoto, H
论文数: 0引用数: 0
h-index: 0
机构:
Kasugai Municipal Hosp, Div Cardiovasc Surg, Kasugai, Aichi 4868510, JapanKasugai Municipal Hosp, Div Cardiovasc Surg, Kasugai, Aichi 4868510, Japan
Masumoto, H
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY,
2005,
129
(05):
: 1195
-
1196
机构:
Univ Paris Est, Fac Med, Creteil, France
Hop Univ Henri Mondor, AP HP, Serv Anesthesie & Reanimat Chirurg, F-94000 Creteil, FranceUniv Paris Est, Fac Med, Creteil, France
Vodovar, Dominique
Haouache, Hakim
论文数: 0引用数: 0
h-index: 0
机构:
Univ Paris Est, Fac Med, Creteil, France
Hop Univ Henri Mondor, AP HP, Serv Anesthesie & Reanimat Chirurg, F-94000 Creteil, FranceUniv Paris Est, Fac Med, Creteil, France
Haouache, Hakim
Dhonneur, Gilles
论文数: 0引用数: 0
h-index: 0
机构:
Univ Paris Est, Fac Med, Creteil, France
Hop Univ Henri Mondor, AP HP, Serv Anesthesie & Reanimat Chirurg, F-94000 Creteil, FranceUniv Paris Est, Fac Med, Creteil, France