Low-Tilt Monophasic and Biphasic Waveforms Compared with Standard Biphasic Waveforms in the Transvenous Defibrillation of Ventricular Fibrillation
被引:4
|
作者:
Bennett, Johan R.
论文数: 0引用数: 0
h-index: 0
机构:
Royal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Queens Univ Belfast, Belfast, Antrim, North IrelandRoyal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Bennett, Johan R.
[1
,2
]
Darragh, Karen M.
论文数: 0引用数: 0
h-index: 0
机构:
Royal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Queens Univ Belfast, Belfast, Antrim, North IrelandRoyal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Darragh, Karen M.
[1
,2
]
Walsh, Simon J.
论文数: 0引用数: 0
h-index: 0
机构:
Royal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North IrelandRoyal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Walsh, Simon J.
[1
]
Allen, Desmond J.
论文数: 0引用数: 0
h-index: 0
机构:
Queens Univ Belfast, Belfast, Antrim, North IrelandRoyal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Allen, Desmond J.
[2
]
Scott, Michael
论文数: 0引用数: 0
h-index: 0
机构:
Wythenshawe Hosp, Dept Pathol, Manchester M23 9LT, Lancs, EnglandRoyal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Scott, Michael
[3
]
Stevenson, Michael
论文数: 0引用数: 0
h-index: 0
机构:
Queens Univ Belfast, Belfast, Antrim, North IrelandRoyal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Stevenson, Michael
[2
]
Adgey, Jennifer A. A.
论文数: 0引用数: 0
h-index: 0
机构:
Royal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Queens Univ Belfast, Belfast, Antrim, North IrelandRoyal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Adgey, Jennifer A. A.
[1
,2
]
Anderson, John M. C. J.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Ulster, Northern Ireland Bioengn, Jordanstown, North IrelandRoyal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Anderson, John M. C. J.
[4
]
Manoharan, Ganesh
论文数: 0引用数: 0
h-index: 0
机构:
Royal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Queens Univ Belfast, Belfast, Antrim, North Ireland
Univ Ulster, Northern Ireland Bioengn, Jordanstown, North IrelandRoyal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
Manoharan, Ganesh
[1
,2
,4
]
机构:
[1] Royal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
[2] Queens Univ Belfast, Belfast, Antrim, North Ireland
[3] Wythenshawe Hosp, Dept Pathol, Manchester M23 9LT, Lancs, England
[4] Univ Ulster, Northern Ireland Bioengn, Jordanstown, North Ireland
BackgroundCommercially available implantable defibrillators utilize a high-tilt waveform. Studies in atrial fibrillation and transthoracic defibrillation of ventricular fibrillation (VF) have shown improved defibrillation efficacy using low-tilt (LT) waveforms. We investigated the feasibility, efficacy, and safety of a LT waveform in the transvenous defibrillation of VF and hypothesized that it would be more efficacious than standard tilted biphasic (STB) waveforms. Methods and ResultsThe investigation was performed in four phases in a porcine model: an efficacy study of LT monophasic waveforms (n= 9), an efficacy study of LT biphasic waveforms (n= 9), a comparison study between the most successful LT waveforms and clinically available STB waveforms (n= 15), and a safety study (n= 9). A total of 1,056 shocks were delivered (phase 1: 288, phase 2: 288, phase 3: 480). The LT biphasic 8/4-ms waveform was significantly more likely to successfully defibrillate than the LT monophasic and STB waveforms with an odds ratio of 122.3 (95% confidence interval: 32.5, 460.2, P< 0.001). The calculated defibrillation threshold (E50) for the LT 8/4-ms waveform was 12.7 J compared to 43.5 J and 45.5 J for STB waveforms 6/6 ms and 8/4 ms, respectively, and 47.7 J for LT 12-ms waveform. The LT 8/4-ms waveform had no lasting detrimental effect on cardiac function, and any transient hemodynamical or biochemical changes observed were comparable to those observed with STB waveforms. ConclusionLT waveforms are effective and appear safe in transvenous defibrillation in a porcine model of VF. The LT biphasic 8/4-ms waveform is more efficacious than conventional waveforms.
机构:
Centre of Biomedical Engineering, Bulgarian Academy of Sciences, 105 Acad. G. Bonchev Str., 1113 Sofia, BulgariaCentre of Biomedical Engineering, Bulgarian Academy of Sciences, 105 Acad. G. Bonchev Str., 1113 Sofia, Bulgaria
Krasteva, V.
Trendafllova, E.
论文数: 0引用数: 0
h-index: 0
机构:
Centre of Biomedical Engineering, Bulgarian Academy of Sciences, 105 Acad. G. Bonchev Str., 1113 Sofia, BulgariaCentre of Biomedical Engineering, Bulgarian Academy of Sciences, 105 Acad. G. Bonchev Str., 1113 Sofia, Bulgaria
Trendafllova, E.
Cansell, A.
论文数: 0引用数: 0
h-index: 0
机构:
Centre of Biomedical Engineering, Bulgarian Academy of Sciences, 105 Acad. G. Bonchev Str., 1113 Sofia, BulgariaCentre of Biomedical Engineering, Bulgarian Academy of Sciences, 105 Acad. G. Bonchev Str., 1113 Sofia, Bulgaria
Cansell, A.
Daskalov, I.
论文数: 0引用数: 0
h-index: 0
机构:
Centre of Biomedical Engineering, Bulgarian Academy of Sciences, 105 Acad. G. Bonchev Str., 1113 Sofia, BulgariaCentre of Biomedical Engineering, Bulgarian Academy of Sciences, 105 Acad. G. Bonchev Str., 1113 Sofia, Bulgaria