Low-Tilt Monophasic and Biphasic Waveforms Compared with Standard Biphasic Waveforms in the Transvenous Defibrillation of Ventricular Fibrillation

被引:4
|
作者
Bennett, Johan R. [1 ,2 ]
Darragh, Karen M. [1 ,2 ]
Walsh, Simon J. [1 ]
Allen, Desmond J. [2 ]
Scott, Michael [3 ]
Stevenson, Michael [2 ]
Adgey, Jennifer A. A. [1 ,2 ]
Anderson, John M. C. J. [4 ]
Manoharan, Ganesh [1 ,2 ,4 ]
机构
[1] Royal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
[2] Queens Univ Belfast, Belfast, Antrim, North Ireland
[3] Wythenshawe Hosp, Dept Pathol, Manchester M23 9LT, Lancs, England
[4] Univ Ulster, Northern Ireland Bioengn, Jordanstown, North Ireland
来源
关键词
ventricular fibrillation; defibrillation; low tilt; waveform; RADIOFREQUENCY-POWERED DEFIBRILLATOR; IMPLANTABLE ATRIAL DEFIBRILLATOR; TRANSTHORACIC DEFIBRILLATION; INTERNAL DEFIBRILLATION; EFFICACY; CARDIOVERSION; ARRHYTHMIAS; HUMANS;
D O I
10.1111/pace.12266
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundCommercially available implantable defibrillators utilize a high-tilt waveform. Studies in atrial fibrillation and transthoracic defibrillation of ventricular fibrillation (VF) have shown improved defibrillation efficacy using low-tilt (LT) waveforms. We investigated the feasibility, efficacy, and safety of a LT waveform in the transvenous defibrillation of VF and hypothesized that it would be more efficacious than standard tilted biphasic (STB) waveforms. Methods and ResultsThe investigation was performed in four phases in a porcine model: an efficacy study of LT monophasic waveforms (n= 9), an efficacy study of LT biphasic waveforms (n= 9), a comparison study between the most successful LT waveforms and clinically available STB waveforms (n= 15), and a safety study (n= 9). A total of 1,056 shocks were delivered (phase 1: 288, phase 2: 288, phase 3: 480). The LT biphasic 8/4-ms waveform was significantly more likely to successfully defibrillate than the LT monophasic and STB waveforms with an odds ratio of 122.3 (95% confidence interval: 32.5, 460.2, P< 0.001). The calculated defibrillation threshold (E50) for the LT 8/4-ms waveform was 12.7 J compared to 43.5 J and 45.5 J for STB waveforms 6/6 ms and 8/4 ms, respectively, and 47.7 J for LT 12-ms waveform. The LT 8/4-ms waveform had no lasting detrimental effect on cardiac function, and any transient hemodynamical or biochemical changes observed were comparable to those observed with STB waveforms. ConclusionLT waveforms are effective and appear safe in transvenous defibrillation in a porcine model of VF. The LT biphasic 8/4-ms waveform is more efficacious than conventional waveforms.
引用
收藏
页码:279 / 289
页数:11
相关论文
共 50 条
  • [31] Triphasic waveforms are superior to biphasic waveforms for transthoracic defibrillation - Experimental studies
    Zhang, Y
    Ramabadran, RS
    Boddicker, KA
    Bawaney, I
    Davies, LR
    Zimmerman, B
    Wuthrich, S
    Jones, JL
    Kerber, RE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (03) : 568 - 575
  • [32] Porcine defibrillation thresholds with chopped biphasic waveforms
    Sullivan, JL
    Schmitt, PW
    Melnick, S
    Walcott, GP
    Ideker, RE
    CIRCULATION, 2005, 112 (17) : U1195 - U1195
  • [33] A comparison of biphasic and monophasic waveform defibrillation after prolonged ventricular fibrillation
    Tang, WC
    Weil, MH
    Sun, SJ
    Povoas, HP
    Klouche, K
    Kamohara, T
    Bisera, J
    CHEST, 2001, 120 (03) : 948 - 954
  • [34] Arrhythmogenicity of monophasic and biphasic PFA waveforms in a porcine model
    Kumru, Hanife Tugba
    Mattison, Lars
    Tarakji, Khaldoun G.
    Verma, Atul
    Sigg, Daniel C.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024,
  • [35] Effect of electrode polarity on internal defibrillation with monophasic and biphasic waveforms using an endocardial lead system
    Huang, J
    KenKnight, BH
    Walcott, GP
    Walker, RG
    Smith, WA
    Ideker, RE
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (02) : 161 - 171
  • [36] Transthoracic defibrillation of dogs with Edmark, biphasic, and quadriphasic waveforms
    McDaniel, WC
    Magin, T
    Madsen, RW
    Bonagura, JD
    Schuder, JC
    Curtis, JJ
    JOURNAL OF ELECTROCARDIOLOGY, 2002, 35 (01) : 45 - 52
  • [37] Biphasic waveforms for ventricular defibrillation: Optimization of total pulse and second phase durations
    Matula, MH
    Brooks, MJ
    Pan, Q
    Pless, BD
    Province, RA
    Echt, DS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (09): : 2154 - 2162
  • [38] The effect of biphasic waveform tilt in transvenous atrial defibrillation
    Sra, J
    Bremner, S
    Krum, D
    Dhala, A
    Blanck, Z
    Deshpande, S
    Biehl, M
    Li, HG
    Jazayeri, MR
    Akhtar, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (06): : 1613 - 1618
  • [39] Transthoracic defibrillation with chopping-modulated biphasic waveforms
    Krasteva, V
    Cansell, A
    Daskalov, IK
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 2001, 25 (04) : 163 - 168
  • [40] Transthoracic defibrillation with chopping-modulated biphasic waveforms
    Krasteva, V.
    Cansell, A.
    Daskalov, I.K.
    Journal of Medical Engineering and Technology, 2001, 25 (04): : 163 - 168