Assessment of water quality of first-flush roof runoff and harvested rainwater

被引:120
|
作者
Gikas, Georgios D. [1 ]
Tsihrintzis, Vassilios A. [1 ]
机构
[1] Democritus Univ Thrace, Lab Ecol Engn & Technol, Dept Environm Engn, Sch Engn, GR-67100 Xanthi, Greece
关键词
Rainwater harvesting; Roof runoff quality; First-flush; Nutrients; Microbial indicators; Principal component analysis; SOUTHEAST QUEENSLAND; GREECE; AUSTRALIA;
D O I
10.1016/j.jhydrol.2012.08.020
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Six pilot rainwater harvesting systems were installed in five urban, suburban and rural houses, and on a university campus. The systems consist of horizontal gutters to collect roof drainage, and downdrains which end into one or two plastic storage tanks. Devices were also provided to remove first-flush water. Water quality was monitored in the storage tanks and the first-flush devices during the 2-year period from October 2006 to November 2008. Water samples were collected at a frequency of once every 10 days, and analyzed according to potable water specifications to determine major anions (e.g., SO24-, NO3-, NO2-, F-, Cl-) and cations (e.g., NH4+, Na+, K+, Ca2+, Mg2+), total suspended solids, alkalinity, total phosphorus and microbiological indicators (e.g., total coliforms, Escherichia coli, Streptococcus, Clostridium perfrigens, Pseudomonas syringae and total viable counts at 22 degrees C and 37 degrees C). Furthermore, temperature, pH, dissolved oxygen and electrical conductivity were measured in situ. The mean concentrations of chemical parameters in harvested rainwater (with the exception of NH4+) were below the limits set by the 98/93/EU directive for drinking water. Total coliforms were detected in 84.4-95.8% of the collected rainwater samples in the six tanks. E. coli, Streptococcus, C. perfrigens, P. syringae and total viable counts at 22 degrees C and 37 degrees C were found at low counts in samples of collected rainwater. The collected rainwater quality was found satisfactory regarding its physicochemical parameters, but not regarding its sanitary quality. Therefore, rainwater harvesting systems in this area could only supply water appropriate for use as gray water. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 126
页数:12
相关论文
共 50 条
  • [31] Theoretical relationships between first flush of roof runoff and influencing factors
    Biao WANG Tian LI State Key Lab of Pollution Control and Resource Reuse Tongji University Shanghai China
    [J]. JournalofZhejiangUniversity(ScienceA:AnInternationalAppliedPhysics&EngineeringJournal)., 2009, 10 (05) - 757
  • [32] Quality assessment of non-roof harvested rainwater in industrial layouts of Enugu, South East Nigeria
    Okudo, Calistus C.
    Ekere, Nwachukwu R.
    Okoye, Chukwuma O. B.
    [J]. APPLIED WATER SCIENCE, 2023, 13 (05)
  • [33] Theoretical relationships between first flush of roof runoff and influencing factors
    Biao Wang
    Tian Li
    [J]. Journal of Zhejiang University-SCIENCE A, 2009, 10 : 746 - 757
  • [34] Quality assessment of non-roof harvested rainwater in industrial layouts of Enugu, South East Nigeria
    Calistus C. Okudo
    Nwachukwu R. Ekere
    Chukwuma O. B. Okoye
    [J]. Applied Water Science, 2023, 13
  • [35] Theoretical relationships between first flush of roof runoff and influencing factors
    Wang, Biao
    Li, Tian
    [J]. JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2009, 10 (05): : 746 - 757
  • [36] Quality assessment of rainwater and harvested rainwater stored in different types of cisterns
    Wu, Lina
    Gao, Jianen
    Zhao, Wenjun
    Xu, Xiuquan
    Yin, Yan
    Wu, Lei
    [J]. WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2017, 17 (03): : 652 - 664
  • [37] Comparative assessment of the effect of storage vessels, thatched roof and industrial activity on harvested rainwater quality in south eastern, Nigeria using water quality index
    Eno-obong Sunday Nicholas
    Pius Onyeoziri Ukoha
    Janefrances Ngozi Ihedioha
    [J]. Discover Water, 4 (1):
  • [38] Development of a fabricated first-flush rainwater harvested technology to meet up the freshwater scarcity in a South Asian megacity, Dhaka, Bangladesh (vol 9, e13027, 2023)
    Jamal, A. H. M. Shofiul Islam Molla
    Tarek, Yeasin Arafat
    Siddique, Md. Abu Bakar
    Shaikh, Md. Aftab Ali
    Debnath, Sumon Chandra
    Uddin, Md. Ripaj
    Ahmed, Shamim
    Akbor, Md. Ahedul
    Al-Mansur, Muhammad Abdullah
    Islam, Abu Reza Md. Towfiqul
    Khan, Rahat
    Moniruzzaman, Mohammad
    Sultana, Shahnaz
    [J]. HELIYON, 2023, 9 (03)
  • [39] Evaluation of a first-flush capture and detention tank receiving runoff from an asphalt-paved road
    Cheng, Jing
    Yuan, Qingke
    Youngchul, Kim
    [J]. WATER AND ENVIRONMENT JOURNAL, 2017, 31 (03) : 410 - 417
  • [40] An evaluation of rainwater runoff quality from selected white roof membranes
    Cupido, Anthony
    Baetz, Brian
    Guo, Yiping
    Robertson, Anna
    [J]. WATER QUALITY RESEARCH JOURNAL OF CANADA, 2012, 47 (01): : 66 - 79