Assessment of water quality of first-flush roof runoff and harvested rainwater

被引:120
|
作者
Gikas, Georgios D. [1 ]
Tsihrintzis, Vassilios A. [1 ]
机构
[1] Democritus Univ Thrace, Lab Ecol Engn & Technol, Dept Environm Engn, Sch Engn, GR-67100 Xanthi, Greece
关键词
Rainwater harvesting; Roof runoff quality; First-flush; Nutrients; Microbial indicators; Principal component analysis; SOUTHEAST QUEENSLAND; GREECE; AUSTRALIA;
D O I
10.1016/j.jhydrol.2012.08.020
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Six pilot rainwater harvesting systems were installed in five urban, suburban and rural houses, and on a university campus. The systems consist of horizontal gutters to collect roof drainage, and downdrains which end into one or two plastic storage tanks. Devices were also provided to remove first-flush water. Water quality was monitored in the storage tanks and the first-flush devices during the 2-year period from October 2006 to November 2008. Water samples were collected at a frequency of once every 10 days, and analyzed according to potable water specifications to determine major anions (e.g., SO24-, NO3-, NO2-, F-, Cl-) and cations (e.g., NH4+, Na+, K+, Ca2+, Mg2+), total suspended solids, alkalinity, total phosphorus and microbiological indicators (e.g., total coliforms, Escherichia coli, Streptococcus, Clostridium perfrigens, Pseudomonas syringae and total viable counts at 22 degrees C and 37 degrees C). Furthermore, temperature, pH, dissolved oxygen and electrical conductivity were measured in situ. The mean concentrations of chemical parameters in harvested rainwater (with the exception of NH4+) were below the limits set by the 98/93/EU directive for drinking water. Total coliforms were detected in 84.4-95.8% of the collected rainwater samples in the six tanks. E. coli, Streptococcus, C. perfrigens, P. syringae and total viable counts at 22 degrees C and 37 degrees C were found at low counts in samples of collected rainwater. The collected rainwater quality was found satisfactory regarding its physicochemical parameters, but not regarding its sanitary quality. Therefore, rainwater harvesting systems in this area could only supply water appropriate for use as gray water. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 126
页数:12
相关论文
共 50 条
  • [21] A field study on the first flush effect of copper roof runoff
    Athanasiadis, K.
    Horn, H.
    Helmreich, B.
    [J]. CORROSION SCIENCE, 2010, 52 (01) : 21 - 29
  • [22] Water quality of first flush runoff from 20 industrial sites
    Line, DE
    Wu, J
    Arnold, JA
    Jennings, GD
    Rubin, AR
    [J]. WATER ENVIRONMENT RESEARCH, 1997, 69 (03) : 305 - 310
  • [23] Partitioning and First-Flush of Nitrogen in Rainfall-Runoff from an Urban Source Area
    Zhang, H.
    Sansalone, J.
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING, 2014, 140 (08)
  • [24] Microbiological Quality of Roof-Harvested Rainwater and Health Risks: A Review
    Ahmed, W.
    Gardner, T.
    Toze, S.
    [J]. JOURNAL OF ENVIRONMENTAL QUALITY, 2011, 40 (01) : 13 - 21
  • [25] Quality of roof-harvested rainwater - Comparison of different roofing materials
    Lee, Ju Young
    Bak, Gippeum
    Han, Mooyoung
    [J]. ENVIRONMENTAL POLLUTION, 2012, 162 : 422 - 429
  • [26] Quality of Harvested Rainwater from a Green and a Bitumen Roof in an Air Polluted
    Tsanov, Emil
    Valchev, Dobril
    Ribarova, Irina
    Dimova, Galina
    [J]. CIVIL ENGINEERING JOURNAL-TEHRAN, 2024, 10 (05): : 1589 - 1605
  • [27] Seasonality assessment of the first flush phenomenon in a rainwater system
    de Souza, Caroline Moreira
    Areas de Almeida, Jaqueline Costa
    Alves, Leticia Delduque
    Domingos, Ryan Rodrigues
    Bila, Daniele Maia
    Ohnuma, Alfredo Akira, Jr.
    [J]. ENGENHARIA SANITARIA E AMBIENTAL, 2022, 27 (03) : 571 - 583
  • [28] The effect of roof surface area on the quality and quantity of rainwater runoff in the rainwater harvesting system
    Faza, K.
    Suwartha, N.
    [J]. 2ND INTERNATIONAL CONFERENCE ON ENVIRONMENT, SUSTAINABILITY ISSUES, AND COMMUNITY DEVELOPMENT, 2021, 623
  • [29] Runoff pollution characterization and first flush effect of urban roof catchment
    Zhang, Wei
    Zhang, Xiaoyue
    Fan, Jingli
    Shi, Zhennan
    Zhao, Yuhua
    Li, Simin
    [J]. DESALINATION AND WATER TREATMENT, 2018, 119 : 262 - 266
  • [30] Characterization and first flush analysis in road and roof runoff in Shenyang, China
    Li, Chunlin
    Liu, Miao
    Hu, Yuanman
    Gong, Jiping
    Sun, Fengyun
    Xu, Yanyan
    [J]. WATER SCIENCE AND TECHNOLOGY, 2014, 70 (03) : 397 - 406