Assessment of PCL between dental implant prosthesis and natural teeth using a digital force analyzer

被引:4
|
作者
Alqahtani, Nasser M. [1 ]
Alqahtani, Ali Fahed [2 ]
Zarbah, Mohammad A. [1 ]
Alqahtani, Saeed M. [1 ]
Shukla, Anuj Kishor [3 ]
Kulkarni, Manisha Mangesh [4 ]
机构
[1] King Khalid Univ, Coll Dent, Dept Prosthet Dent, Abha, Saudi Arabia
[2] King Khalid Univ, Coll Dent, Dept Periodont & Community Dent, Abha, Saudi Arabia
[3] Govt Med Coll, Dept Dent, Ratlam, India
[4] YCMM RDFs Dent Coll, Dept Prosthodont, Ahmednagar, India
关键词
Proximal contact loss; implant supported prosthesis (ISP); contact area; digital force analyzer; PROXIMAL CONTACT LOSS; ADJACENT TEETH; RESTORATIONS; PREVALENCE;
D O I
10.3233/THC-220028
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: The prime concern of an implant-supported prosthesis (ISP) is to maintain an optimal proximal contact tightness, which further maintains arch integrity, improves masticatory effectiveness, and minimizes peri-implantitis. OBJECTIVE: To investigate the loss of proximal contact tightness between single tooth implant-supported prosthesis and the adjacent natural teeth. METHODS: Forty patients treated by a single mandibular first molar ISP, aged between 18-50 years were selected. All were randomly allocated in Group I and Group II. Group I, 20 subjects who have received ISP without an insertion of Essix retainer, and Group II patients received an insertion with Essix retainer. The groups were subdivided into Subgroup A, B, and Subgroup C, D, in which A and C are control groups. To measure the tightness at proximal contact points, a digital force analyzer was used. Proximal contact tightness (PCT) was measured immediately after the placement of the prosthesis, 3 months, 6 months, and 1-year follow-up respectively, and the PCT values at end of 1 year were statistically evaluated. Statistical analysis was done, mean and standard deviation was calculated by independent sample t-test wit p < 0.05 as a statistically significant value. RESULTS: In Group I, towards the end of 1 year, 2.09 N (65.5%) and 1.50 N (53.1%) loss of PCT were found on mesial and distal contact areas respectively. In Group II, loss of PCT at mesial contact area was 0.87 N (28.9%) and at distal contact area was 1.77 N (53.3%), which is significantly less compared with the non-usage of Essix retainer (p < 0.05). CONCLUSION: The usage of Essix retainer, PCT increases especially on the mesial contact area. The frequency of contact loss was decreased. Thus, to minimize the loss of proximal contact the usage of Essix retainer is recommended.
引用
收藏
页码:1435 / 1442
页数:8
相关论文
共 50 条
  • [41] Proximal contact loss between implant-supported prostheses and adjacent natural teeth: a retrospective study
    Wong, Anita T. Y.
    Wat, Peter Y. P.
    Pow, Edmond H. N.
    Leung, Katherine C. M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (04) : e68 - e71
  • [42] Pairs of natural teeth rather than use of dental prosthesis are associated with nutritional status in older adults: A cross-sectional study
    Dantas, Pedro Paulo de Almeida
    Colussi, Paulo Roberto Grafitti
    Dezingrini, Koriandher da Silva
    Sachetti, Diandra Genoveva
    Muniz, Francisco Wilker Mustafa Gomes
    JOURNAL OF DENTISTRY, 2021, 108
  • [43] A Combined Digital Technique for Manufacturing Functional Fixed Implant Prosthesis Prototypes Using a CAD/CAM Software
    Altemimi, Aseel
    Rodriguez, Julio
    Nahon, Max
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (01): : 85 - 90
  • [44] A TECHNIQUE TO RESTORE WORN DENTURE TEETH ON A PARTIAL REMOVABLE DENTAL PROSTHESIS BY USING CERAMIC ONLAYS WITH CAD/CAM TECHNOLOGY
    Yoon, Tae-Ho
    Madden, John C.
    Chang, Won-Gun
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (04): : 331 - 332
  • [45] Comparison between digital panoramic radiography and cone-beam computed tomography for the identification of the mandibular canal as part of presurgical dental implant assessment
    Angelopoulos, Christos
    Thomas, Stephen
    Hechler, Stephen
    Parissis, Nikos
    Hlavacek, Matt
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (10) : 2130 - 2135
  • [46] A Digital Image Correlation Analysis of Strain Generated by 3-Unit Implant-Supported Fixed Dental Prosthesis: An In Vitro Study
    Peixoto, Raniel F.
    Macedo, Ana P.
    Martinelli, Janisse
    Lapria Faria, Adriana C.
    Tiossi, Rodrigo
    Ribeiro, Ricardo F.
    de Mattos, Maria da G. C.
    IMPLANT DENTISTRY, 2017, 26 (04) : 567 - 573
  • [47] An alternative digital workflow for fabricating a mandibular implant-supported complete fixed dental prosthesis with limited restorative space: A clinical report
    Belur, Druthil
    Nagy, William W.
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (01): : 1 - 4
  • [48] Assessment of Dental Arch Reproduction Quality by Using Traditional and Digital Methods
    Wojcik, Mateusz
    Skaba, Dariusz
    Skucha-Nowak, Malgorzata
    Tanasiewicz, Marta
    Wiench, Rafal
    APPLIED SCIENCES-BASEL, 2021, 11 (03): : 1 - 13
  • [49] Comparative Study between an Immediate Loading Protocol Using the Digital Workflow and a Conventional Protocol for Dental Implant Treatment: A Randomized Clinical Trial
    Rattanapanich, Piyanut
    Aunmeungtong, Weerapan
    Chaijareenont, Pisaisit
    Khongkhunthian, Pathawee
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (05)
  • [50] Evaluation of the correlation between dental occlusion and posture using a force platform
    Baldini, Alberto
    Nota, Alessandro
    Tripodi, Domenico
    Longoni, Salvatore
    Cozza, Paola
    CLINICS, 2013, 68 (01) : 45 - 49