Assessment of PCL between dental implant prosthesis and natural teeth using a digital force analyzer

被引:4
|
作者
Alqahtani, Nasser M. [1 ]
Alqahtani, Ali Fahed [2 ]
Zarbah, Mohammad A. [1 ]
Alqahtani, Saeed M. [1 ]
Shukla, Anuj Kishor [3 ]
Kulkarni, Manisha Mangesh [4 ]
机构
[1] King Khalid Univ, Coll Dent, Dept Prosthet Dent, Abha, Saudi Arabia
[2] King Khalid Univ, Coll Dent, Dept Periodont & Community Dent, Abha, Saudi Arabia
[3] Govt Med Coll, Dept Dent, Ratlam, India
[4] YCMM RDFs Dent Coll, Dept Prosthodont, Ahmednagar, India
关键词
Proximal contact loss; implant supported prosthesis (ISP); contact area; digital force analyzer; PROXIMAL CONTACT LOSS; ADJACENT TEETH; RESTORATIONS; PREVALENCE;
D O I
10.3233/THC-220028
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: The prime concern of an implant-supported prosthesis (ISP) is to maintain an optimal proximal contact tightness, which further maintains arch integrity, improves masticatory effectiveness, and minimizes peri-implantitis. OBJECTIVE: To investigate the loss of proximal contact tightness between single tooth implant-supported prosthesis and the adjacent natural teeth. METHODS: Forty patients treated by a single mandibular first molar ISP, aged between 18-50 years were selected. All were randomly allocated in Group I and Group II. Group I, 20 subjects who have received ISP without an insertion of Essix retainer, and Group II patients received an insertion with Essix retainer. The groups were subdivided into Subgroup A, B, and Subgroup C, D, in which A and C are control groups. To measure the tightness at proximal contact points, a digital force analyzer was used. Proximal contact tightness (PCT) was measured immediately after the placement of the prosthesis, 3 months, 6 months, and 1-year follow-up respectively, and the PCT values at end of 1 year were statistically evaluated. Statistical analysis was done, mean and standard deviation was calculated by independent sample t-test wit p < 0.05 as a statistically significant value. RESULTS: In Group I, towards the end of 1 year, 2.09 N (65.5%) and 1.50 N (53.1%) loss of PCT were found on mesial and distal contact areas respectively. In Group II, loss of PCT at mesial contact area was 0.87 N (28.9%) and at distal contact area was 1.77 N (53.3%), which is significantly less compared with the non-usage of Essix retainer (p < 0.05). CONCLUSION: The usage of Essix retainer, PCT increases especially on the mesial contact area. The frequency of contact loss was decreased. Thus, to minimize the loss of proximal contact the usage of Essix retainer is recommended.
引用
收藏
页码:1435 / 1442
页数:8
相关论文
共 50 条
  • [21] Retrospective assessment of dental implant-related perforations of relevant anatomical structures and inadequate spacing between implants/teeth using cone-beam computed tomography
    Hugo Gaêta-Araujo
    Nicolly Oliveira-Santos
    Arthur Xavier Maseti Mancini
    Matheus Lima Oliveira
    Christiano Oliveira-Santos
    Clinical Oral Investigations, 2020, 24 : 3281 - 3288
  • [22] Assessment of dental age estimation using dentinal translucency in ground sections of single rooted teeth: a digital image analysis
    Durand, Abelene Maria
    Narayan, Madhu
    Karthik, Raghavendhar
    Krishnan, Rajkumar
    Srinivasan, Narasimhan
    Kumar, Dinesh
    ANATOMY & CELL BIOLOGY, 2024, 57 (02) : 271 - 277
  • [23] A digital technique of bone reduction for a maxillary full-arch implant-supported fixed dental prosthesis
    Tang, Weimao
    Zhang, Hai
    Wang, Haozhe
    Li, Lei
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (07): : 714 - 719
  • [24] Obtaining reliable intraoral digital scans for an implant-supported complete-arch prosthesis: A dental technique
    Iturrate, Mikel
    Minguez, Rikardo
    Pradies, Guillermo
    Solaberrieta, Eneko
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (02): : 237 - 241
  • [25] Microbiota of dental implants, crowned and natural teeth using DNA probes.
    Lee, KH
    Weber, HP
    Maiden, MFJ
    Tanner, A
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 498 - 498
  • [26] THE CONSTRUCTION PECULIARITIES OF ARTIFICIAL DENTAL ARCHES OF FULL REMOVABLE PROSTHESIS WITH USING OF TEETH MODELS AND ALVEOLAR ARCHES
    Chizhikova, T. S.
    Mnatsakanyan, A., V
    Borodina, V. A.
    Torokhova, V. O.
    Timircheva, V. V.
    ARCHIV EUROMEDICA, 2018, 8 (02): : 106 - 110
  • [27] The Accuracy of Digital Implant Impressions when Using and Varying the Material and Diameter of the Dental Implant Scan Bodies
    Althubaitiy, Ramzi
    Sambrook, Raelene
    Weisbloom, Michael
    Petridis, Haralampos
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2022, 30 (04): : 305 - 313
  • [28] Optimizing protocols for preparation and imaging of natural teeth, dental implant and peri-implant tissues in high vacuum, low vacuum, and environmental SEM
    Tessarolo, F.
    Piccoli, F.
    Caola, I.
    Tomasi, C.
    Bressan, E.
    Nollo, G.
    Caciagli, P.
    JOURNAL OF APPLIED BIOMATERIALS & BIOMECHANICS, 2009, 7 (01) : 73 - 74
  • [29] ASSESSMENT OF THE REPRODUCIBILITY OF STRENGTH AND ENDURANCE HANDGRIP PARAMETERS USING A DIGITAL ANALYZER
    WALAMIES, M
    TURJANMAA, V
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1993, 67 (01): : 83 - 86
  • [30] ASSESSMENT OF IN VITRO DENTAL IMPLANT PRIMARY STABILITY USING AN ULTRASONIC METHOD
    Vayron, Romain
    Mathieu, Vincent
    Michel, Adrien
    Haiat, Guillaume
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (12): : 2885 - 2894