Assessment of PCL between dental implant prosthesis and natural teeth using a digital force analyzer

被引:4
|
作者
Alqahtani, Nasser M. [1 ]
Alqahtani, Ali Fahed [2 ]
Zarbah, Mohammad A. [1 ]
Alqahtani, Saeed M. [1 ]
Shukla, Anuj Kishor [3 ]
Kulkarni, Manisha Mangesh [4 ]
机构
[1] King Khalid Univ, Coll Dent, Dept Prosthet Dent, Abha, Saudi Arabia
[2] King Khalid Univ, Coll Dent, Dept Periodont & Community Dent, Abha, Saudi Arabia
[3] Govt Med Coll, Dept Dent, Ratlam, India
[4] YCMM RDFs Dent Coll, Dept Prosthodont, Ahmednagar, India
关键词
Proximal contact loss; implant supported prosthesis (ISP); contact area; digital force analyzer; PROXIMAL CONTACT LOSS; ADJACENT TEETH; RESTORATIONS; PREVALENCE;
D O I
10.3233/THC-220028
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: The prime concern of an implant-supported prosthesis (ISP) is to maintain an optimal proximal contact tightness, which further maintains arch integrity, improves masticatory effectiveness, and minimizes peri-implantitis. OBJECTIVE: To investigate the loss of proximal contact tightness between single tooth implant-supported prosthesis and the adjacent natural teeth. METHODS: Forty patients treated by a single mandibular first molar ISP, aged between 18-50 years were selected. All were randomly allocated in Group I and Group II. Group I, 20 subjects who have received ISP without an insertion of Essix retainer, and Group II patients received an insertion with Essix retainer. The groups were subdivided into Subgroup A, B, and Subgroup C, D, in which A and C are control groups. To measure the tightness at proximal contact points, a digital force analyzer was used. Proximal contact tightness (PCT) was measured immediately after the placement of the prosthesis, 3 months, 6 months, and 1-year follow-up respectively, and the PCT values at end of 1 year were statistically evaluated. Statistical analysis was done, mean and standard deviation was calculated by independent sample t-test wit p < 0.05 as a statistically significant value. RESULTS: In Group I, towards the end of 1 year, 2.09 N (65.5%) and 1.50 N (53.1%) loss of PCT were found on mesial and distal contact areas respectively. In Group II, loss of PCT at mesial contact area was 0.87 N (28.9%) and at distal contact area was 1.77 N (53.3%), which is significantly less compared with the non-usage of Essix retainer (p < 0.05). CONCLUSION: The usage of Essix retainer, PCT increases especially on the mesial contact area. The frequency of contact loss was decreased. Thus, to minimize the loss of proximal contact the usage of Essix retainer is recommended.
引用
收藏
页码:1435 / 1442
页数:8
相关论文
共 50 条
  • [1] Digital articulation of a complete arch fixed implant prosthesis using the implant prosthetic connections: A dental technique
    Hamilton, Adam
    Griseto, Neil
    Negreiros, William Matthew
    Gallucci, German O.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (05): : 793 - 799
  • [2] An Assessment of Cutting Force for Dental Implant Drilling
    Hwang, Joon
    Chung, Eui-Sik
    Lee, Yong-Kyu
    ADVANCED MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 472-475 : 2542 - +
  • [3] An assessment of cutting force for dental implant drilling
    Dept. of Aeronautical and Mechanical Design Engineering, Chungju National University, 50 Daehak-ro, Chungju, Chung-Buk 380-702, Korea, Republic of
    不详
    不详
    Adv. Mater. Res., (2542-2547):
  • [4] Comparative Analysis of Gingival Wetness at Natural Teeth and Dental Implant Sites
    Askin, Sezen B.
    Guncu, Guliz N.
    Yamalik, Nermin
    IMPLANT DENTISTRY, 2012, 21 (01) : 57 - 61
  • [5] Restoring soft and hard dental tissues using a removable implant prosthesis with digital imaging for optimum dental esthetics: A clinical report
    Amet, EM
    Milana, JP
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2003, 23 (03) : 269 - 275
  • [6] Digital process for an implant-supported fixed dental prosthesis: A clinical report
    Brandt, Jan
    Lauer, Hans-Christoph
    Peter, Thorsten
    Brandt, Silvia
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04): : 469 - 473
  • [7] Magnet-Retained Orbital Prosthesis Using a Dental Implant
    Kim, Soung Min
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (02) : E151 - E152
  • [8] APPARENT INTRUSION OF NATURAL TEETH UNDER AN IMPLANT-SUPPORTED PROSTHESIS - A CLINICAL REPORT
    CHO, GC
    CHEE, WWL
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (01): : 3 - 5
  • [9] From Denture to the Final Implant-Supported Prosthesis Using a Full-Digital Protocol: A Dental Technique
    Todescan, Francisco Fernando
    Hayashi, Marcos Masayuki
    Giugni, Luiz Roberto
    Bottino, Marco Antonio
    Tribst, Joao Paulo Mendes
    ORAL, 2021, 1 (04): : 332 - 339
  • [10] Assessment of complications in adjacent natural teeth compared to contralateral teeth in single posterior implant cases
    Fridenberg, Naama
    Tagger-Green, Nirit
    Katz, Matanel
    Levartovsky, Shifra
    SCIENTIFIC REPORTS, 2025, 15 (01):