Out-of-plane computed-tomography-guided biopsy using a magnetic-field-based navigation system

被引:25
|
作者
Wallace, MJ [1 ]
Gupta, S [1 ]
Hicks, ME [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Diagnost Radiol, Sect Vasc & Intervent Radiol, Houston, TX 77030 USA
关键词
biopsy; image guidance; navigation system;
D O I
10.1007/s00270-005-0041-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this article is to report our clinical experience with out-of-plane computed-tomography (CT)-guided biopsies using a magnetic-field-based navigation system. Between February 2002 and March 2003, 20 patients underwent CT-guided biopsy in which an adjunct magnetic-field-based navigation system was used to aid an out-of-plane biopsy approach. Eighteen patients had an underlying primary malignancy. All biopsies involved the use of a coaxial needle system in which an outer 18G guide needle was inserted to the lesion using the navigation system and an inner 22G needle was then used to obtain fine-needle aspirates. Complications and technical success were recorded. Target lesions were located in the adrenal gland (n = 7), liver (n = 6), pancreas (n = 3), lung (n = 2), retroperitoneal lymph node (n = 1), and pelvis (n = 1). The mean lesion size (maximum transverse diameter) was 26.5 mm (range: 8-70 mm) and the mean and median cranial-caudal distance, between the transaxial planes of the final needle tip location and the needle insertion site, was 40 mm (range: 18-90 mm). Needle tip positioning was successfully placed within the lesion in all 20 biopsies. A diagnosis of malignancy was obtained in 14 biopsies. Benign diagnoses were encountered in the remaining six biopsies and included a benign adrenal gland (n = 2), fibroelastic tissue (n = 1), hepocytes with steatosis (n = 2) and reactive hepatocytes (n = 1). No complications were encountered. A magnetic-field-based navigation system is an effective adjunct tool for accurate and safe biopsy of lesions that require an out-of-plane CT approach.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 45 条
  • [11] Computed tomography-guided transgluteal prostate biopsy using a coaxial needle system: technical note
    Chan, RP
    Chung, DG
    [J]. CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2003, 54 (03): : 181 - 182
  • [12] Percutaneous bone biopsy using a flat-panel cone beam computed tomography virtual navigation system
    Liu, Juan-Fang
    Jiao, De-Chao
    Ren, Jian-Zhuang
    Zhang, Wen-Guang
    Han, Xin-Wei
    [J]. SAUDI MEDICAL JOURNAL, 2018, 39 (05) : 519 - 523
  • [13] Percutaneous computed tomography-guided lung biopsies: preliminary results using an augmented reality navigation system
    Grasso, Rosario Francesco
    Luppi, Giacomo
    Cazzato, Roberto Luigi
    Faiella, Eliodoro
    D'Agostino, Francesco
    Zobel, Daniela Beomonte
    De Lena, Mario
    [J]. TUMORI JOURNAL, 2012, 98 (06): : 775 - 782
  • [14] UNDERSTANDING THE SEQUENCE OF DAMAGE IN COMPLEX HYBRID COMPOSITE-METALLIC STRUCTURES SUBJECT TO OUT-OF-PLANE LOADING INVESTIGATED USING COMPUTED TOMOGRAPHY
    Allen, T.
    Ahmed, S.
    Reed, P. A. S.
    Sinclair, I
    Spearing, S. M.
    [J]. 20TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS, 2015,
  • [15] Out-of-Plane Motion Detection System Using Convolutional Neural Network for US-guided Radiofrequency Ablation Therapy
    Ryosuke, Kondo
    Norihiro, Koizumi
    Yu, Nishiyama
    Naoki, Matsumoto
    Kazushi, Numata
    [J]. 2018 15TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS (UR), 2018, : 729 - 731
  • [16] Transbronchial Biopsy Using an Ultrathin Bronchoscope Guided by Cone-Beam Computed Tomography and Virtual Bronchoscopic Navigation in the Diagnosis of Pulmonary Nodules
    Ali, Eman A. A.
    Takizawa, Hiromitsu
    Kawakita, Naoya
    Sawada, Toru
    Tsuboi, Mitsuhiro
    Toba, Hiroaki
    Takashima, Mika
    Matsumoto, Daisuke
    Yoshida, Mitsuteru
    Kawakami, Yukikiyo
    Kondo, Kazuya
    El-Badrawy, Mohammad Khairy
    Tangoku, Akira
    [J]. RESPIRATION, 2019, 98 (04) : 321 - 328
  • [17] Pedicle Morphology Using Computed Tomography-based Navigation System in Adolescent Idiopathic Scoliosis
    Kuraishi, Shuugo
    Takahashi, Jun
    Hirabayashi, Hiroki
    Hashidate, Hiroyuki
    Ogihara, Nobuhide
    Mukaiyama, Keijiro
    Kato, Hiroyuki
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (01): : 22 - 28
  • [18] First experience with zero-fluoroscopic ablation for supraventricular tachycardias using a novel impedance and magnetic-field-based mapping system
    Katie A. Walsh
    Joseph Galvin
    John Keaney
    Edward Keelan
    Gabor Szeplaki
    [J]. Clinical Research in Cardiology, 2018, 107 : 578 - 585
  • [19] A new pulse electromagnet structure to model a transverse magnetic field to pick up the out-of-plane for laser-EMAT integrated system
    Yuan, Wei
    Liu, Ze
    Zhao, Pengfei
    Huo, Jiwei
    [J]. AIP ADVANCES, 2022, 12 (09)
  • [20] First experience with zero-fluoroscopic ablation for supraventricular tachycardias using a novel impedance and magnetic-field-based mapping system
    Walsh, Katie A.
    Galvin, Joseph
    Keaney, John
    Keelan, Edward
    Szeplaki, Gabor
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (07) : 578 - 585