The Effects of Cortical Bone Thickness and Trabecular Bone Strength on Noninvasive Measures of the Implant Primary Stability Using Synthetic Bone Models

被引:56
|
作者
Hsu, Jui-Ting [1 ]
Fuh, Lih-Jyh [1 ]
Tu, Ming-Gene [1 ]
Li, Yu-Fen [2 ,3 ]
Chen, Kuan-Ting [2 ]
Huang, Heng-Li [1 ]
机构
[1] China Med Univ, Sch Dent, Taichung 40402, Taiwan
[2] China Med Univ, Ctr Biostat, Taichung 40402, Taiwan
[3] China Med Univ, Grad Inst Biostat, Taichung 40402, Taiwan
关键词
cortical bone thickness; implant primary stability; insertion torque; periotest; resonance frequency analysis; strength of trabecular bone; RESONANCE FREQUENCY-ANALYSIS; DENTAL IMPLANTS; CANCELLOUS BONE; FINITE-ELEMENT; HUMAN CADAVER; OSSEOINTEGRATION; DENSITY; AUGMENTATION; OSTEOPOROSIS; SIMULATION;
D O I
10.1111/j.1708-8208.2011.00349.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study investigated how the primary stability of a dental implant as measured by the insertion torque value (ITV), Periotest value (PTV), and implant stability quotient (ISQ) is affected by varying thicknesses of cortical bone and strengths of trabecular bone using synthetic bone models. Materials and Methods: Four synthetic cortical shells (with thicknesses of 0, 1, 2, and 3mm) were attached to four cellular rigid polyurethane foams (with elastic moduli of 137, 47.5, 23, and 12.4MPa) and one open-cell rigid polyurethane foam which mimic the osteoporotic bone (with an elastic modulus 6.5MPa), to represent the jawbones with various cortical bone thicknesses and strengths of trabecular bone. A total of 60 bone specimens accompanied with implants was examined by a torque meter, Osstell resonance frequency analyzer, and Periotest electronic device. All data were statistically analyzed by two-way analysis of variance. In addition, second-order nonlinear regression was utilized to assess the correlations of the primary implant stability with the four cortex thicknesses and five strengths of trabecular bone. Results: ITV, ISQ, and PTV differed significantly (p<.05) and were strongly correlated with the thickness of cortical bone (R2>0.9) and the elastic modulus of trabecular bone (R2=0.740.99). Conclusions: The initial stability at the time of implant placement is influenced by both the cortical bone thickness and the strength of trabecular bone; however, these factors are mostly nonlinearly correlated with ITV, PTV, and ISQ. Using ITV and PTV seems more suitable for identifying the primary implant stability in osteoporotic bone with a thin cortex.
引用
收藏
页码:251 / 261
页数:11
相关论文
共 50 条
  • [1] Effects of cortical bone thickness and trabecular bone density on primary stability of orthodontic mini-implants
    Pan, Chin-Yun
    Liu, Pao-Hsin
    Tseng, Yu-Chuan
    Chou, Szu-Ting
    Wu, Chao-Yi
    Chang, Hong-Po
    JOURNAL OF DENTAL SCIENCES, 2019, 14 (04) : 383 - 388
  • [2] Computational analysis of primary implant stability in trabecular bone
    Steiner, Juri A.
    Ferguson, Stephen J.
    van Lenthe, G. Harry
    JOURNAL OF BIOMECHANICS, 2015, 48 (05) : 807 - 815
  • [3] Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In Vitro Model Study
    Wang, Russell
    Eppell, Steven J.
    Nguyen, Christian
    Morris, Nathan
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (02) : 145 - 152
  • [4] The Effects of Alendronate or Denosumab on Cortical and Trabecular Bone Mass, Bone Strength, and Bone Mass-Strength Relationships in Mice
    Ominsky, M. S.
    Li, X.
    Tan, H.
    Asuncion, F. J.
    Barrero, M.
    Tian, X. Y.
    Warmington, K. S.
    Dwyer, D.
    Grisanti, M.
    Stolina, N.
    Jee, W. S.
    Simonet, W. S.
    Ke, H. Z.
    Kostenuik, P. J.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 : S40 - S40
  • [5] THE EFFECTS OF PRIMARY HYPERPARATHYROIDISM ON TRABECULAR AND CORTICAL BONE MASS
    ADAMS, JE
    WHITEHOUSE, RW
    ADAMS, PH
    DAVIES, M
    CALCIFIED TISSUE INTERNATIONAL, 1990, 46 (02) : 144 - 144
  • [6] Growth of cortical bone thickness and trabecular bone density in Japanese children
    Ozaki, Etsuko
    Matsukawa, Mami
    Mano, Isao
    Matsui, Daisuke
    Yoneda, Yutaro
    Masumura, Misako
    Koyama, Teruhide
    Watanabe, Isao
    Maekawa, Mizuho
    Tomida, Satomi
    Iwasa, Koichi
    Umemura, Shiori
    Kuriyama, Nagato
    Uehara, Ritei
    BONE, 2020, 141
  • [7] Bone cement grafting increases implant primary stability in circumferential cortical bone defects
    Shin, Seung-Yun
    Shin, Seung-Il
    Kye, Seung-Beom
    Chang, Seok-Woo
    Hong, Jongrak
    Paeng, Jun-Young
    Yang, Seung-Min
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2015, 45 (01): : 30 - 35
  • [8] Effects of Cortical Bone Thickness and Implant Length on Bone Strain and Interfacial Micromotion in an Immediately Loaded Implant
    Tu, Ming-Gene
    Hsu, Jui-Ting
    Fuh, Lih-Jyh
    Lin, Dan-Jae
    Huang, Heng-Li
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 706 - 714
  • [9] EFFECTS OF KWASHIORKOR ON CORTICAL AND TRABECULAR BONE
    ADAMS, P
    BERRIDGE, FR
    ARCHIVES OF DISEASE IN CHILDHOOD, 1969, 44 (238) : 705 - &
  • [10] The Interrelation between Cortical Bone Thickness and Primary and Secondary Dental Implant Stability: a Systematic Review
    Al-Juboori, Halah
    Petronis, Zygimantas
    Razukevicius, Dainius
    JOMR-JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH, 2024, 15 (04):