Routine evaluation of left ventricular diastolic function by cardiovascular magnetic resonance: A practical approach

被引:104
|
作者
Rathi, Vikas K. [1 ]
Doyle, Mark [1 ]
Yamrozik, June [1 ]
Williams, Ronald B. [1 ]
Caruppannan, Ketheswaram [1 ]
Truman, Craig [1 ]
Vido, Diane [1 ]
Biederman, Robert W. W. [1 ]
机构
[1] Drexel Univ, Allegheny Gen Hosp, Div Cardiol, Coll Med, Pittsburgh, PA 15212 USA
关键词
D O I
10.1186/1532-429X-10-36
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiovascular magnetic resonance (CMR) has excellent capabilities to assess ventricular systolic function. Current clinical scenarios warrant routine evaluation of ventricular diastolic function for complete evaluation, especially in congestive heart failure patients. To our knowledge, no systematic assessment of diastolic function over a range of lusitropy has been performed using CMR. Methods and Results: Left ventricular diastolic function was assessed in 31 subjects (10 controls) who underwent CMR and compared with Transthoracic echocardiogram (TTE) evaluation of mitral valve (MV) and pulmonary vein (PV) blood flow. Blood flow in the MV and PV were successfully imaged by CMR for all cases (31/31,100%) while TTE evaluated flow in all MV (31/31,100%) but only 21/31 PV (68%) cases. Velocities of MV flow (E and A) measured by CMR correlated well with TTE (r = 0.81, p < 0.001), but demonstrated a systematic underestimation by CMR compared to TTE (slope = 0.77). Bland-Altman analysis of the E: A ratio and deceleration time (DT) calculated from each modality showed excellent agreement (bias -0.29, and -10.3 ms for E: A and DT, respectively). When assessing morphology using TTE, CMR correctly identified patients as having normal or abnormal inflow conditions. Conclusion: We have shown that there is homology between CMR and TTE for the assessment of diastolic inflow over a wide range of conditions, including normal, impaired relaxation and restrictive. There is excellent agreement of quantitative velocity measurements between CMR and TTE. Diastolic blood flow assessment by CMR can be performed in a single scan, with times ranging from 20 sec to 3 min, and we show that there is good indication for applying CMR to assess diastolic conditions, either as an adjunctive test when evaluating systolic function, or even as a primary test when TTE data cannot be obtained.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] EVALUATION OF LEFT-VENTRICULAR DIASTOLIC FUNCTION
    LEW, WYW
    CIRCULATION, 1989, 79 (06) : 1393 - 1397
  • [22] Evaluation of Left Ventricular Diastolic Function by the Intensivist
    Greenstein, Yonatan Y.
    Mayo, Paul H.
    CHEST, 2018, 153 (03) : 723 - 732
  • [24] Echocardiographic evaluation of left ventricular diastolic function
    Nagueh S.F.
    Current Cardiovascular Imaging Reports, 2008, 1 (1) : 30 - 38
  • [25] Impact of diastolic dysfunction severity on global left ventricular volumetric filling - assessment by automated segmentation of routine cine cardiovascular magnetic resonance
    Dorinna D Mendoza
    Noel CF Codella
    Yi Wang
    Martin R Prince
    Sonia Sethi
    Shant J Manoushagian
    Keigo Kawaji
    James K Min
    Troy M LaBounty
    Richard B Devereux
    Jonathan W Weinsaft
    Journal of Cardiovascular Magnetic Resonance, 12
  • [26] Impact of diastolic dysfunction severity on global left ventricular volumetric filling - assessment by automated segmentation of routine cine cardiovascular magnetic resonance
    Mendoza, Dorinna D.
    Codella, Noel C. F.
    Wang, Yi
    Prince, Martin R.
    Sethi, Sonia
    Manoushagian, Shant J.
    Kawaji, Keigo
    Min, James K.
    LaBounty, Troy M.
    Devereux, Richard B.
    Weinsaft, Jonathan W.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12 : 1 - 11
  • [27] Left ventricular structure and diastolic function by cardiac magnetic resonance imaging in hypertrophic cardiomyopathy
    Chacko, Binita Riya
    Karur, Gauri R.
    Connelly, Kim A.
    Yan, Raymond T.
    Kirpalani, Anish
    Wald, Rachel
    Jimenez-Juan, Laura
    Jacob, John Roshan
    Deva, Djeven P.
    Yan, Andrew T.
    INDIAN HEART JOURNAL, 2018, 70 (01) : 75 - 81
  • [28] Left ventricular diastolic function with cardiac magnetic resonance imaging in systemic sclerosis patients
    Agoston-Coldea, L.
    Marjanovic, Z.
    Kachenoura, N.
    Lupu, S.
    Farge-Bancel, D.
    Mousseaux, E.
    EUROPEAN JOURNAL OF HEART FAILURE, 2016, 18 : 392 - 392
  • [29] Is Intraoperative Strain Analysis for Left Ventricular Diastolic Function Practical?
    Sheu, Richard
    Ferreira, Renata
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (06) : 1492 - 1494
  • [30] Automated Segmentation of Routine Clinical Cardiac Magnetic Resonance Imaging for Assessment of Left Ventricular Diastolic Dysfunction
    Kawaji, Keigo
    Codella, Noel C. F.
    Prince, Martin R.
    Chu, Christopher W.
    Shakoor, Aqsa
    LaBounty, Troy M.
    Min, James K.
    Swaminathan, Rajesh V.
    Devereux, Richard B.
    Wang, Yi
    Weinsaft, Jonathan W.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (06) : 476 - 484